压缩感知二维脊柱磁共振成像(MRI)的初步研究
在5名志愿者中优化压缩感知(CS)成像方案,并对71例患者(颈椎22例、胸椎8例、腰椎41例)行二维矢状位T1WI、矢状位T2WI和轴位T2WI的CS-MRI与非CS-MRI对比;CS-MRI平均扫描时间4分28.7秒±34.6秒,显著短于非CS-MRI的7分21.3秒±38.7秒(t=-47.464,P<0.0001),且信噪比和对比噪声比更高,病灶诊断观察者间与研究方法间一致性均优秀(kappa值0.913至1.000,P<0.001)。
要点
- 脊柱CS-MRI平均扫描时间4分28.7秒±34.6秒,较非CS-MRI的7分21.3秒±38.7秒显著缩短(P<0.0001)。
- CS-MRI在图像质量评估中信噪比和对比噪声比均高于非CS-MRI。
- 两种方法病灶诊断观察者间一致性kappa值0.913至1.000,研究方法间一致性kappa值1.000(P<0.001)。
核心结论
- 脊柱CS-MRI可显著缩短扫描时间,同时保持与非CS-MRI相当的图像质量。
研究设计与样本
- 在5名志愿者中优化CS成像方案,随后对71例患者(颈椎22例、胸椎8例、腰椎41例)行二维矢状位T1WI、矢状位T2WI和轴位T2WI的CS-MRI与非CS-MRI对比;由3名放射科医师独立评估图像质量和病灶诊断,采用配对t检验比较扫描时间、信噪比和对比噪声比,Kendall W检验评估观察者间一致性,Wilcoxon检验比较图像质量,kappa分析评估病灶诊断的观察者间及研究方法间一致性。
诊断标准与关键数值
- CS-MRI平均扫描时间4分28.7秒±34.6秒,非CS-MRI为7分21.3秒±38.7秒(t=-47.464,P<0.0001);CS-MRI图像质量评估中信噪比和对比噪声比高于非CS-MRI;病灶诊断观察者间一致性kappa值0.913至1.000(P<0.001),研究方法间一致性kappa值1.000(P<0.001)。
临床应用与阅片要点
- 原文结论认为CS-MRI脊柱成像可显著缩短扫描时间,同时保持与非CS-MRI相当的图像质量。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the feasibility of compressed sensing MRI (CS-MRI) in the application of 2D spinal imaging and compare its performance with conventional MR imaging (non-CS-MRI).
METHODS: The CS imaging protocol was optimized on 5 volunteers. Non-CS-MRI and CS-MRI of 2D sagittal T1 weighted imaging (WI), Sag T2WI, and axial T2WI were performed for 71 patients (22 cervical, 8 thoracic, 41 lumbar MRI). Paired t tests were conducted to compare the total scan time. Three radiologists assessed image quality and lesion diagnosis independently. A Kendall W test was performed to assess interobserver agreement of the image quality scores and lesion diagnosis between readers. A nonparametric test (Wilcoxon test) was performed to compare the image quality. For lesion diagnosis, the interobserver and interstudy agreements were evaluated by kappa analysis. Paired t tests were conducted for SNR and CNR comparison.
RESULTS: The mean scan time for spine CS-MRI (4 min 28.7 s ± 34.6 s) was significantly shorter than that with non-CS-MRI (7 min 21.3 s ± 38.7 s, t = - 47.464, P < 0.0001). CS-MRI achieved higher SNR and CNR than Non-CS-MRI in image quality assessment. Interobserver agreements of lesion diagnosis were excellent between non-CS-MRI and CS-MRI (kappa value from 0.913 to 1.000, P < 0.001). Interstudy agreements of lesion assessments were also excellent (kappa value = 1.000, with P < 0.001).
CONCLUSION: CS-MRI spine imaging can significantly reduce the scan time, while maintaining comparable imaging quality to non-CS-MRI.
引用
- Qiu, Liu, Bi, et al. An Investigation of 2D Spine Magnetic Resonance Imaging (MRI) with Compressed Sensing (CS). Skeletal Radiol. 2021. PMID: 34854969. doi:10.1007/s00256-021-03954-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。