文献速递泌尿生殖妇产影像MR

MRI特征鉴别黏液性交界性卵巢肿瘤与黏液性卵巢癌

MRI characteristics for differentiating mucinous borderline ovarian tumours from mucinous ovarian cancers.
PubMed 文献 · Clin Radiol · 2021-11-27

回顾性分析75例黏液性交界性卵巢肿瘤(MBOT)和38例黏液性卵巢癌(MOC)患者的MRI资料,比较临床病理及MRI特征。MBOT与MOC在乳头状突起、实性成分最大径、实性成分强化率、ADC值及腹水方面差异有统计学意义。ADC值最佳截断值为1.16×10⁻³ mm²/s,鉴别两者敏感度87.1%、特异度83.3%、AUC 0.917。

要点

  • MBOT较MOC乳头状突起或实性成分更少、强化率更低、ADC值更高。
  • MBOT较少出现中到大量腹水,MOC则相对更常见。
  • 实性成分ADC值鉴别MBOT与MOC的AUC为0.917,最佳截断值1.16×10⁻³ mm²/s。

核心结论

  • 与MOC相比,MBOT乳头状突起或实性成分更少、强化率更低、ADC值更高,且较少出现中到大量腹水。

研究设计与样本

  • 回顾性研究,纳入75例MBOT患者和38例MOC患者,比较临床病理及MRI特征,采用单变量分析和多变量逻辑回归分析。

关键影像表现/征象

  • MBOT与MOC在乳头状突起存在与否方面差异有统计学意义(p=0.013)。
  • MBOT与MOC在实性成分最大径方面差异有统计学意义(p=0.001)。
  • MBOT与MOC在实性成分强化率方面差异有统计学意义(p=0.003)。
  • MBOT与MOC在ADC值方面差异有统计学意义(p<0.001)。
  • MBOT与MOC在腹水方面差异有统计学意义(p<0.001)。

诊断标准与关键数值

  • 实性成分ADC值鉴别MBOT与MOC的最佳截断值为1.16×10⁻³ mm²/s,敏感度87.1%,特异度83.3%,AUC为0.917。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the magnetic resonance imaging (MRI) characteristics that could differentiate mucinous borderline ovarian tumours (MBOTs) from mucinous ovarian cancers (MOCs).

MATERIALS AND METHODS: MRI data from 75 patients with MBOTs and 38 patients with MOCs were reviewed retrospectively. The clinicopathological and MRI features, including age, bilaterality, maximum diameter (MD), shape, margin, configuration, cystic-solid interface, papillae, MD of the cyst walls and septa, MD of the solid components, number of cysts, honeycomb loculi, signal of the cystic and solid components, apparent diffusion coefficient (ADC) value and enhancement ratio of the solid components, peritoneal implants and ascites, were compared using univariable analysis and multivariable logistic regression analysis.

RESULTS: There were 76 MBOTs and 39 MOCs, and median patient age was 41 years (range 16-77 years) and 51 years (range 15-90 years), respectively (p=0.004). There were significant differences between MBOTs and MOCs regarding the presence of papillae (p=0.013), MD of the solid components (p=0.001), enhancement ratio of the solid components (p=0.003), ADC value (p<0.001), and ascites (p<0.001). The optimal cut-off ADC value was 1.16 × 10-3 mm2/s, with a sensitivity of 87.1%, a specificity of 83.3%, and an area under the curve (AUC) of 0.917.

CONCLUSION: Compared with MOCs, MBOTs had fewer papillae or solid components, lower enhancement ratio, higher ADC values, and were less likely to have moderate or massive ascites.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Yang, Li, Ma, et al. MRI characteristics for differentiating mucinous borderline ovarian tumours from mucinous ovarian cancers. Clin Radiol. 2021. PMID: 34848025. doi:10.1016/j.crad.2021.10.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。