卵巢囊腺瘤:生长速率与影像测量的可靠性
研究评估良性卵巢囊腺瘤的生长速率及超声测量的变异性。社区队列405例女性1412次超声显示中位生长速率0.65 cm/年,黏液性囊腺瘤0.83 cm/年快于浆液性0.51 cm/年(P<.0001)。三级转诊75例女性176次超声显示测量误差与生长速率量级相似,提示可能需要超过一年的间隔复查以准确评估生长。
要点
- 良性卵巢囊腺瘤中位生长速率0.65 cm/年,黏液性0.83 cm/年快于浆液性0.51 cm/年(P<.0001)。
- 超声测量误差与年生长速率量级相似,总体11%的测量差异超过1 cm。
- 动态影像与静态图像测量误差不同,评估生长时需考虑测量方法的影响。
核心结论
- 囊腺瘤平均生长0.65 cm/年,与超声固有测量误差量级相似,提示若囊肿为良性囊腺瘤,可能需要超过一年的间隔复查以准确评估生长。
研究设计与样本
- 两项独立回顾性队列:社区健康系统405例女性1412次超声评估生长速率(混合效应模型,基于最大报告尺寸);三级转诊75例女性176次超声评估测量变异性(两名放射科医生独立测量,相关系数和Bland-Altman分析)。
诊断标准与关键数值
- 生长速率基于最大报告尺寸维度,中位0.65 cm/年;黏液性囊腺瘤0.83 cm/年,浆液性囊腺瘤0.51 cm/年(中位数检验P<.0001)。
- 测量变异性:受试者内标准差动态影像0.74 cm、静态图像0.41 cm;总体11%的测量差异超过1 cm。
临床应用与阅片要点
- 评估卵巢囊腺瘤生长时需考虑超声测量误差,动态影像与静态图像测量误差不同。
- 若囊肿为良性囊腺瘤,可能需要超过一年的间隔复查以准确评估生长。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the growth rate of benign ovarian cystadenomas and the degree of variability in ultrasound measurements.
METHODS: Two independent retrospective cohorts of women found to have benign cystadenomas at surgery were identified. To assess growth rate, ultrasounds on women in a community-based health system were reviewed and the growth rate was determined based on the maximum reported size dimension using a mixed effect model. To assess measurement variability, two radiologists independently measured presurgical adnexal imaging findings for women in a tertiary care referral setting. Interobserver, intra-observer, and intermodality (cine clip versus still images) variability in measurements was determined using correlation coefficients (CC) and Bland-Altman analysis, with the proportion of measurements varying by more than 1 cm calculated.
RESULTS: For growth rate assessment, 405 women with 1412 ultrasound examinations were identified. The median growth rate was 0.65 cm/year with mucinous cystadenomas growing faster at 0.83 cm/year compared to 0.51 cm/year for serous cystadenomas (median test P < .0001). To evaluate measurement variability, 75 women were identified with 176 ultrasound studies. The within-subject standard deviations for ultrasound measurements were 0.74 cm for cine clip images and 0.41 cm for static images, with 11% of measurements overall differing by more than 1 cm.
CONCLUSIONS: Cystadenomas grow on average 0.65 cm/year, which is similar in magnitude to the inherent error observed in measurement on ultrasound, suggesting that repeat ultrasound at intervals of longer than a year will often be needed to accurately assess growth if a cyst represents a benign cystadenoma.
引用
- Suh-Burgmann, Nakhaei, Gupta, et al. Ovarian Cystadenomas: Growth Rate and Reliability of Imaging Measurements. J Ultrasound Med. 2021. PMID: 34846072. doi:10.1002/jum.15895
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。