文献速递腹部CT

超高清CT评估胃壁结构

Assessment of gastric wall structure using ultra-high-resolution computed tomography.
PubMed 文献 · Eur J Radiol · 2021-11-24

回顾性纳入48例接受增强超高清CT的患者,比较深度学习重建与其他三种重建方法的图像噪声和整体质量,并比较常规高清CT与超高清CT对胃壁三层结构显示清晰度;超高清CT使用深度学习重建噪声更低、整体质量更优,且胃壁三层结构清晰度在胃底、胃体、胃角及胃窦后壁优于常规高清CT。

要点

  • 超高清CT联合深度学习重建可降低胃壁图像噪声并提高整体图像质量。
  • 超高清CT对胃壁三层结构的显示在胃底、胃体、胃角、胃窦后壁优于常规高清CT。
  • 胃窦前壁三层结构清晰度在超高清CT与常规高清CT间无显著差异(P=0.230)。

核心结论

  • 超高清CT使用深度学习重建改善了胃壁的图像噪声和整体图像质量以及三层结构的清晰度,提示其可用于评估胃壁结构的解剖细节。

研究设计与样本

  • 回顾性研究纳入48例接受增强超高清CT的患者,比较深度学习重建与滤波反投影、混合迭代重建、基于模型的迭代重建四种方法的图像噪声和整体图像质量评分,并比较常规高清CT与超高清CT对胃壁五个区域三层结构的清晰度评分。

关键影像表现/征象

  • 超高清CT使用深度学习重建的平均噪声显著低于其他三种重建方法(P<0.001)。
  • 超高清CT使用深度学习重建的平均整体图像质量评分显著高于其他三种重建方法(P<0.001)。

诊断标准与关键数值

  • 胃壁三层结构清晰度评分:胃底超高清CT 5[5-5] vs 常规高清CT 3.5[3-4],P<0.001。
  • 胃体超高清CT 4[3.25-5] vs 常规高清CT 4[3-4],P=0.039。
  • 胃角超高清CT 5[4-5] vs 常规高清CT 3[2-4],P<0.001。
  • 胃窦后壁超高清CT 4[3.25-5] vs 常规高清CT 2[2-4],P<0.001。
  • 胃窦前壁超高清CT 4[3-5] vs 常规高清CT 3[3-4],P=0.230。

临床应用与阅片要点

  • 超高清CT联合深度学习重建可用于评估胃壁结构解剖细节,提高胃壁三层结构在胃底、胃体、胃角及胃窦后壁的显示清晰度。
  • 胃窦前壁三层结构清晰度在超高清CT与常规高清CT间无显著差异(P=0.230)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the image quality of ultra-high-resolution CT (U-HRCT) in the comparison among four different reconstruction methods, focusing on the gastric wall structure, and to compare the conspicuity of a three-layered structure of the gastric wall between conventional HRCT (C-HRCT) and U-HRCT.

METHOD: Our retrospective study included 48 patients who underwent contrast-enhanced U-HRCT. Quantitative analyses were performed to compare image noise of U-HRCT between deep-learning reconstruction (DLR) and other three methods (filtered back projection: FBP, hybrid iterative reconstruction: Hybrid-IR, and Model-based iterative reconstruction: MBIR). The mean overall image quality scores were also compared between the DLR and other three methods. In addition, the mean conspicuity scores for the three-layered structure of the gastric wall at five regions were compared between C-HRCT and U-HRCT.

RESULTS: The mean noise of U-HRCT with DLR was significantly lower than that with the other three methods (P < 0.001). The mean overall image quality scores with DLR images were significantly higher than those with the other three methods (P < 0.001). Regarding the comparison between C-HRCT and U-HRCT, the mean conspicuity scores for the three-layered structure of the gastric wall on U-HRCT were significantly better than those on C-HRCT in the fornix (5 [5-5] vs. 3.5 [3-4], P < 0.001), body (4 [3.25-5] vs. 4 [3-4], P = 0.039), angle (5 [4-5] vs. 3 [2-4], P < 0.001), and antral posterior (4 [3.25-5] vs. 2 [2-4], P < 0.001), except for antral anterior (4 [3-5] vs. 3 [3-4], P = 0.230) CONCLUSION: U-HRCT using DLR improved the image noise and overall image quality of the gastric wall as well as the conspicuity of the three-layered structure, suggesting its utility for the evaluation of the anatomical details of the gastric wall structure.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Onoda, Tanabe, Higashi, et al. Assessment of gastric wall structure using ultra-high-resolution computed tomography. Eur J Radiol. 2021. PMID: 34847396. doi:10.1016/j.ejrad.2021.110067

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。