肺部超声评估胸膜线异常、融合B线与实变:专家可重复性及标准化方法
研究针对融合B线、实变和胸膜线异常提出定义,利用COVID-19患者相控阵探头图像分析两名评分者协作及独立评分者的可重复性。结果显示B线异常和胸膜线至实变异常的一致性优良,但仅胸膜线异常的一致性弱,提示单一相控阵探头判读胸膜线异常需谨慎。
要点
- 融合B线和胸膜线至实变异常的整体一致性优良(ICC 0.88–0.97)。
- 仅胸膜线异常的一致性弱(κ=0.54),判读需谨慎。
- 使用相控阵探头时,胸膜线异常的解释应慎重。
核心结论
- 所提定义下,融合B线和胸膜线至实变异常的整体一致性稳健,但胸膜线异常本身一致性持续偏弱,仅用相控阵探头判读胸膜线异常时应谨慎。
研究设计与样本
- 研究提出融合B线、实变和胸膜线异常的定义,两名评分者协作在10例患者的107幅推导扫描上优化定义,随后两名评分者及一名独立评分者在105例患者的1260幅验证扫描上评估可重复性,图像来自COVID-19患者、使用相控阵探头采集,信度用组内相关系数(ICC)或Cohen kappa评价。
诊断标准与关键数值
- 协作评分者间B线异常一致性ICC=0.97(95%CI 0.97-0.98)。
- 协作评分者间胸膜线至实变异常一致性ICC=0.90(95%CI 0.87-0.92)。
- 独立评分者B线异常一致性ICC=0.97(95%CI 0.96-0.97)。
- 独立评分者胸膜线至实变一致性ICC=0.88(95%CI 0.84-0.91)。
- 仅胸膜线异常一致性:协作评分者κ=0.54(95%CI 0.48-0.60),独立评分者κ=0.54(95%CI 0.49-0.59)。
临床应用与阅片要点
- 作者提出融合B线、实变和胸膜线异常的定义,并认为经协作或采用所提定义后,融合B线和胸膜线至实变异常的整体一致性稳健。
- 作者指出胸膜线异常本身一致性持续偏弱,仅用相控阵探头判读胸膜线异常时应谨慎。
局限性
- 原文结论指出胸膜线异常一致性持续偏弱,仅用相控阵探头判读胸膜线异常时应谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Discrete B-lines have clear definitions, but confluent B-lines, consolidations, and pleural line abnormalities are less well defined. We proposed definitions for these and determined their reproducibility using COVID-19 patient images obtained with phased array probes.
METHODS: Two raters collaborated to refine definitions, analyzing disagreements on 107 derivation scans from 10 patients. Refined definitions were used by those raters and an independent rater on 1260 validation scans from 105 patients. Reliability was evaluated using intraclass correlation coefficients (ICC) or Cohen's kappa.
RESULTS: The agreement was excellent between collaborating raters for B-line abnormalities, ICC = 0.97 (95% confidence interval [CI] 0.97-0.98) and pleural line to consolidation abnormalities, ICC = 0.90 (95% CI 0.87-0.92). The independent rater's agreement for B-line abnormalities was excellent, ICC = 0.97 (95% CI 0.96-0.97) and for pleural line to consolidation was good, ICC = 0.88 (95% CI 0.84-0.91). Agreement just on pleural line abnormalities was weak (collaborators, κ = 0.54, 95% CI 0.48-0.60; independent, κ = 0.54, 95% CI 0.49-0.59).
CONCLUSION: With proposed definitions or via collaboration, overall agreement on confluent B-lines and pleural line to consolidation abnormalities was robust. Pleural line abnormality agreement itself was persistently weak and caution should be used interpreting pleural line abnormalities with only a phased array probe.
引用
- Fischer, Minami, Ma, et al. Lung Ultrasound for Pleural Line Abnormalities, Confluent B-Lines, and Consolidation: Expert Reproducibility and a Method of Standardization. J Ultrasound Med. 2021. PMID: 34845735. doi:10.1002/jum.15894
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。