3特斯拉磁共振成像显示大内淋巴管及内淋巴囊畸形并与听力学相关
回顾性评估30例大内淋巴管及内淋巴囊(LEDS)患者共54耳的3T颞骨MRI,定性及定量分析耳蜗畸形与蜗轴缺陷,并与听力学数据相关。结果显示77.8%的耳存在耳蜗异常,11.1%为孤立性蜗轴缺陷,11.1%耳蜗及蜗轴完全正常;63%的耳X距离增大,LEDS内及耳蜗内T2低信号分别见于42.6%和7.4%的耳。重度至极重度听力损失耳的LEDS中位直径大于正常至中度听力损失耳(p<0.05);X距离、LEDS内T2低信号及蜗轴直径与听力学数据无统计学相关。
要点
- LEDS畸形耳中77.8%伴耳蜗异常,11.1%仅为孤立性蜗轴缺陷,11.1%耳蜗及蜗轴完全正常。
- 63%的LEDS耳X距离增大,42.6%的LEDS内见T2低信号,7.4%的耳蜗内见T2低信号。
- 重度至极重度听力损失耳的LEDS中位直径大于正常至中度听力损失耳(p<0.05)。
核心结论
- 3T高分辨率成像显示LEDS畸形患者存在一系列耳蜗异常,但高达11.1%的耳尽管有严重的内淋巴管/囊扩张和/或极重度听力损失,却无 underlying 耳蜗异常。
研究设计与样本
- 回顾性评估30例LEDS患者共54耳的3T颞骨MRI,定性及定量评估耳蜗畸形与蜗轴缺陷,并记录LEDS严重程度、LEDS及耳蜗内信号改变,与听力学数据相关。
关键影像表现/征象
- 77.8%的耳耳蜗异常,其中11.1%为孤立性蜗轴缺陷,11.1%的耳耳蜗及蜗轴完全正常。
- 63%的耳X距离增大。
- LEDS内T2低信号见于42.6%的耳,耳蜗内T2低信号见于7.4%的耳。
- 重度至极重度听力损失耳的LEDS中位直径高于正常至中度听力损失耳(p<0.05)。
诊断标准与关键数值
- 耳蜗异常率77.8%,孤立性蜗轴缺陷率11.1%,耳蜗及蜗轴完全正常率11.1%。
- X距离增大率63%,LEDS内T2低信号率42.6%,耳蜗内T2低信号率7.4%。
- 重度至极重度听力损失耳与正常至中度听力损失耳相比LEDS中位直径更高(p<0.05)。
- X距离、LEDS内T2低信号及蜗轴直径与听力学数据无统计学相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Large endolymphatic duct and sac (LEDS) is one of the most common imaging abnormalities in congenital sensorineural hearing loss and is frequently seen with coexistent cochlear anomalies, especially incomplete partition type II. However, MRI findings of accompanying cochlear and especially modiolar dysplasias may be subtle. The purpose of this study is to evaluate the imaging findings of LEDS with high-resolution imaging at 3 T and correlate with the audiological data.
METHODS: 3 T temporal bone MRIs of 54 ears in 30 LEDS patients were retrospectively evaluated. The cochlear dysmorphism and modiolar deficiency were assessed qualitatively and quantitatively. The severity of LEDS anomaly, the signal changes within the LEDS and cochlea were also noted. The imaging findings were correlated to the audiological data.
RESULTS: The cochlea was abnormal in 77.8% of the ears with an isolated modiolar deficiency in 11.1%. Cochlea and modiolus were completely normal in 11.1% of the ears. In 63% of the ears X-distance was increased. T2 hypointensity within LEDS and cochlea were detected in 42.6%, and 7.4% of the ears, respectively. The median diameters of LEDS were higher in ears with severe to profound HL than ears with normal to moderate HL (p < 0.05). The X-distance, presence of T2 hypointensity within LEDS, and diameters of modiolus did not show statistical correlation with the audiographic data.
CONCLUSION: High-resolution 3 T imaging of patients with LEDS anomaly revealed a spectrum of cochlear anomalies, but up to 11.1% of the ears had no underlying anomaly despite severe (endolymphatic duct/sac) dilatation and/or profound HL.
引用
- Parlak, Akgoz Karaosmanoglu, Ozbal Batuk, et al. 3 Tesla MR imaging of the large endolymphatic duct and sac anomaly with audiological correlation. Eur J Radiol. 2021. PMID: 34839211. doi:10.1016/j.ejrad.2021.110064
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。