应用剪切波弹性成像预测模型鉴别乳腺良恶性病变及调整超声乳腺影像报告和数据系统分类
研究纳入468例患者共488个乳腺病灶,术前行常规超声和实时剪切波弹性成像(SWE),以组织病理为参考标准。实时SWE指标Emax和Ecol的AUC分别为0.837和0.828,多因素logistic回归构建的SWE预测模型AUC为0.850。该模型有助于鉴别乳腺良恶性病变但不能替代常规超声,并可提高超声BI-RADS 3和4a分类的诊断效能。
要点
- 实时SWE指标Emax鉴别乳腺良恶性病变的AUC为0.837。
- 实时SWE指标Ecol鉴别乳腺良恶性病变的AUC为0.828。
- SWE预测模型鉴别良恶性病变的AUC为0.850,可辅助调整BI-RADS 3和4a分类。
核心结论
- 实时SWE预测模型有助于乳腺良恶性病变的鉴别诊断,但不能替代常规超声。
- 该模型可提高超声BI-RADS 3和4a分类的诊断效能。
研究设计与样本
- 研究纳入468例患者共488个乳腺病灶,病灶经空心针穿刺或手术切除行组织病理学检查。
- 术前2周内行常规超声和实时剪切波弹性成像(SWE)检查。
- 采用统计学分析鉴别乳腺良恶性病变并调整超声BI-RADS 3和4a分类,通过多因素logistic回归构建实时SWE预测模型。
诊断标准与关键数值
- 实时SWE定量指标中Emax鉴别乳腺良恶性病变的诊断效能最高,AUC为0.837。
- 实时SWE定性指标中Ecol鉴别乳腺良恶性病变的诊断效能最高,AUC为0.828。
- 多因素logistic回归构建的实时SWE预测模型诊断乳腺良恶性病变的AUC为0.850。
临床应用与阅片要点
- 实时SWE预测模型可辅助鉴别乳腺良恶性病变,但不能替代常规超声。
- 该模型可用于调整超声BI-RADS 3和4a分类,提高其诊断效能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To explore a real-time shear-wave elastography (SWE) prediction model distinguishing benign from malignant breast lesions and to determine its application in adjusting ultrasound Breast Imaging Reporting and Data System (BI-RADS) classifications.
MATERIALS AND METHODS: Four hundred and sixty-eight patients with 488 breast lesions were enrolled. Patients underwent hollow-needle puncture or surgical resection for histopathological examinations. Ultrasound examinations, both conventional ultrasound and real-time SWE, were performed <2 weeks prior to sampling. Statistical analyses were implemented to distinguish benign from malignant breast lesions and adjust ultrasound BI-RADS 3 and 4a classifications.
RESULTS: The real-time SWE indicators Emax and Ecol showed the highest diagnostic efficiency in distinguishing between benign and malignant lesions through quantitative and qualitative indicators, respectively. The area under the curve (AUC) for Emax was 0.837 while that for Ecol was 0.828. The AUC of the real-time SWE prediction model, constructed by multivariate logistic regression, for diagnosing benign and malignant breast lesions was 0.850.
CONCLUSION: The real-time SWE prediction model aids in the differential diagnosis of benign and malignant breast lesions but cannot replace conventional ultrasound. The model improves the diagnostic performance of ultrasound BI-RADS 3 and 4a classifications.
引用
- Yu, Ye, Yang, et al. Application of a shear-wave elastography prediction model to distinguish between benign and malignant breast lesions and the adjustment of ultrasound Breast Imaging Reporting and Data System classifications. Clin Radiol. 2021. PMID: 34836632. doi:10.1016/j.crad.2021.10.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。