对比增强超声特征与乳腺癌分子亚型之间的关联
本研究纳入116例经病理确诊的乳腺癌患者(116个病灶),术前接受常规超声和对比增强超声(CEUS),分析CEUS定性和定量特征与术后免疫组化确定的Luminal A、Luminal B、HER2过表达和三阴性亚型之间的关联。结果显示四种亚型在增强速度、增强程度、曲线下面积(AUC)、达峰时间(TTP)和峰值强度(PI)上存在显著差异,提示CEUS特征可能有助于预测乳腺癌分子亚型。
要点
- LA亚型AUC(305.1±188.4)显著小于H2(535.7±222.0,P=.007)和TN(496.6±254.7,P=.019)。
- H2亚型TTP(19.8±4.9)显著短于LA(26.3±7.2,P=.008)和LB(23.1±6.7,P=.036)。
- LA亚型PI(4.7±2.3)显著低于LB(6.6±2.3,P=.027)、H2(7.4±2.2,P=.005)和TN(6.9±2.6,P=.014)。
核心结论
- 不同分子亚型乳腺癌的CEUS特征存在显著差异,增强模式和参数可能是预测不同亚型的重要特征。
研究设计与样本
- 本研究为单中心研究,纳入116例经病理确诊的乳腺癌患者(116个病灶),术前接受常规超声和CEUS检查;以术后病理和免疫组化确定的分子亚型(LA、LB、H2过表达、TN)为参考标准。
关键影像表现/征象
- 四种亚型在增强速度和增强程度上存在显著差异(P<.05)。
- LA亚型AUC(305.1±188.4)显著小于H2(535.7±222.0,P=.007)和TN(496.6±254.7,P=.019)。
- H2亚型TTP(19.8±4.9)短于其他亚型,且显著短于LA(26.3±7.2,P=.008)和LB(23.1±6.7,P=.036)。
- LA亚型PI(4.7±2.3)显著低于LB(6.6±2.3,P=.027)、H2(7.4±2.2,P=.005)和TN(6.9±2.6,P=.014)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aimed to investigate the correlation between contrast-enhanced ultrasound (CEUS) features and molecular subtypes of breast cancer (BC).
METHODS: A total of 116 patients (116 lesions) with pathologically diagnosed BC who received conventional ultrasound and CEUS before surgery were enrolled in this study. BC molecular subtypes were identified by postoperative pathological and immunohistochemical analysis as Luminal A (LA), Luminal B (LB), HER2 (H2) over-expression, and triple-negative (TN). Qualitative and quantitative CEUS characteristics were analyzed by one-way analysis of variance (continuous variables) or Pearson's χ2 test or Fisher's exact probability method (categorical variables).
RESULTS: There were significant differences in enhancement speed and enhancement degree among the four subtypes (P < .05). The area under the curve (AUC), time to peak (TTP), and peak intensity (PI) differed among the four subtypes (P < .05). The AUC of the LA subtype (305.1 ± 188.4) was significantly smaller compared with the H2 (535.7 ± 222.0, P = .007) and TN subtypes (496.6 ± 254.7, P = .019). In addition, TTP was shorter in the H2 subtype (19.8 ± 4.9) compared with the other subtypes, and was significantly shorter than in the LA subtype (26.3 ± 7.2, P = .008) and LB subtype (23.1 ± 6.7, P = .036). The PI of the LA subtype (4.7 ± 2.3) was significantly lower than that of the LB (6.6 ± 2.3, P = .027), H2 (7.4 ± 2.2, P = .005), and TN subtypes (6.9 ± 2.6, P = .014).
CONCLUSIONS: CEUS features differed significantly among different molecular subtypes of BC. The enhancement patterns and parameters may be important predictive features of different subtypes of BC.
引用
- Wen, Kong, Zhang, et al. Association Between Contrast-Enhanced Ultrasound Characteristics and Molecular Subtypes of Breast Cancer. J Ultrasound Med. 2021. PMID: 34837655. doi:10.1002/jum.15886
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。