文献速递妇产影像US

低置胎盘妊娠中胎盘植入谱系疾病的第一孕期超声诊断特征

First-trimester ultrasound diagnostic features of placenta accreta spectrum in low-implantation pregnancy.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-03-10

回顾性病例对照研究纳入2009—2019年在本机构分娩、第一孕期超声显示低置胎盘妊娠的产妇,比较21例发生胎盘植入谱系疾病(PAS)者与46例持续性前置胎盘但无PAS者;第一孕期胎盘腔隙、腔隙漩涡征、异常子宫胎盘界面及子宫下段血供增多在PAS病例中更常见,作者认为高危孕妇第一孕期即可评估PAS超声标志。

要点

  • 低置胎盘妊娠第一孕期出现胎盘腔隙时,PAS风险显著升高(OR 33.4,95%CI 7.7-144.4,P<0.001)。
  • 腔隙漩涡征和异常子宫胎盘界面仅见于PAS病例,可作为第一孕期鉴别线索。
  • 子宫下段血供增多在PAS病例中占14/14(100%),对照组仅1/12(8.3%)。

核心结论

  • 在有PAS风险的孕妇中,PAS的超声标志最早可在第一孕期评估;使用第一孕期产前超声筛查方案和标准化检查方法可能有助于提高PAS检出并为受累妊娠的最佳管理提供规划。

研究设计与样本

  • 2009—2019年单中心回顾性病例对照研究;病例为因PAS行剖宫产子宫切除且第一孕期超声显示低置胎盘者21例,对照为无PAS、无产后出血经剖宫产分娩且第一孕期超声显示低置胎盘的持续性前置胎盘者46例;由对妊娠结局和超声报告设盲的研究者复习超声图像。

关键影像表现/征象

  • 胎盘腔隙在病例组18/21(85.7%)中出现,对照组7/46(15.2%)中出现。
  • 腔隙数量病例组中位数5个,对照组中位数1个,病例组高于对照组(P<0.001)。
  • 腔隙大小病例组中位数10.03 mm(IQR 7.3-12.05),对照组4.15 mm(IQR 4.05-5.05),病例组大于对照组(P=0.001)。
  • 腔隙漩涡征仅见于PAS病例,灰阶超声10/12(83.3%)可见,彩色多普勒12/12(100%)可见(P<0.001)。
  • 异常子宫胎盘界面仅见于PAS病例,占17/20(85.0%)(P<0.001);子宫下段(子宫膀胱、胎盘下和/或胎盘内)血供增多在病例组14/14(100%)、对照组1/12(8.3%)中出现(P<0.001)。

诊断标准与关键数值

  • 胎盘腔隙与PAS的关联:OR 33.4(95%CI 7.7-144.4),P<0.001。
  • 腔隙数量病例组中位数5个 vs 对照组中位数1个(P<0.001)。
  • 腔隙大小病例组中位数10.03 mm(IQR 7.3-12.05)vs 对照组4.15 mm(IQR 4.05-5.05)(P=0.001)。

临床应用与阅片要点

  • 对有PAS风险的孕妇,第一孕期超声即可评估胎盘腔隙、腔隙漩涡征、异常子宫胎盘界面及子宫下段血供增多等标志。
  • 作者认为使用第一孕期产前超声筛查方案和标准化检查方法可能有助于提高PAS检出并为受累妊娠的最佳管理提供规划。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Low-implantation pregnancy (LIP) is an important marker for the diagnosis of placenta accreta spectrum (PAS) in the first trimester. Many grayscale and color Doppler ultrasound markers of PAS have been defined in the second and third trimesters of pregnancy, but have not been studied in the first trimester. The aim of this study was to determine whether PAS sonographic markers could be used in the first trimester to differentiate patients with LIP who develop PAS from those who do not.

METHODS: This was a retrospective case-control study of women who delivered at our institution between 2009 and 2019. Cases were women with PAS who delivered by Cesarean hysterectomy and who had undergone first-trimester ultrasound demonstrating LIP. Controls were women with persistent placenta previa without PAS who delivered by Cesarean section without postpartum hemorrhage and who had undergone first-trimester ultrasound demonstrating LIP. Sonographic images were reviewed by an investigator blinded to pregnancy outcome and ultrasound reports. Images were reviewed for presence of abnormal uteroplacental interface, increased lower uterine segment hypervascularity and placental lacunae, with or without swirling on grayscale or color Doppler ultrasound.

RESULTS: Following review of the electronic health records, 21 cases and 46 controls met the inclusion criteria. Placental lacunae were present in 18/21 (85.7%) cases and 7/46 (15.2%) controls (odds ratio (OR), 33.4; 95% CI, 7.7-144.4; P < 0.001). The number of lacunae was significantly higher in cases compared with controls, with a median of five lacunae present in cases compared with a median of one lacuna in controls (P < 0.001). The median size of the lacunae was also significantly larger in cases compared with controls, measuring 10.03 (interquartile range (IQR), 7.3-12.05) mm and 4.15 (IQR, 4.05-5.05) mm, respectively (P = 0.001). Lacunae swirling on grayscale or color Doppler ultrasound was noted only in PAS cases, with 10/12 (83.3%) having swirling on grayscale ultrasound and 12/12 (100%) having swirling on color Doppler (P < 0.001). Presence of an abnormal uteroplacental interface was also observed only in PAS cases, at a rate of 17/20 (85.0%) (P < 0.001). Lower uterine segment (uterovesical, subplacental and/or intraplacental) hypervascularity was present in 14/14 (100%) cases and only 1/12 (8.3%) controls (P < 0.001).

CONCLUSION: In women at risk of PAS, ultrasound markers of PAS can and should be assessed as early as in the first trimester. The use of a first-trimester prenatal ultrasound screening protocol and standardized approach to ultrasound examination in at-risk mothers may help increase detection of PAS and enable planning for optimal management of affected pregnancies. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。