文献速递心血管胸部CT

基于人工智能的冠状动脉钙化积分在非门控胸部CT中的性能评估

Performance of artificial intelligence-based coronary artery calcium scoring in non-gated chest CT.
PubMed 文献 · Eur J Radiol · 2021-11-16

研究纳入901例在3个月内接受胸部CT和心电门控非增强心脏CT的患者,以手工法为参考标准,评估基于深度学习的人工智能冠状动脉钙化积分(AI-CACS)软件在三种CT机型上的风险分类性能。AI-CACS与手工CACS相关性ρ=0.893,风险分类一致率80.6%,κ=0.679,三种机型风险分类无显著差异(p=0.7543)。

要点

  • AI-CACS与手工CACS风险分类一致率80.6%,κ=0.679,相关性ρ=0.893。
  • 以0、100、400为二分界值时,AI-CACS准确率分别为88.6%、92.9%、97.9%。
  • 三种不同厂商CT机型的AI-CACS风险分类无显著差异(p=0.7543)。

核心结论

  • AI-CACS与手工CACS在风险分类方面具有良好的相关性和一致性,基于非门控胸部CT数据用AI软件可在短时间内获得CACS而不增加辐射剂量或经济负担,该算法具有良好临床普适性,可应用于不同厂商的CT机型。

研究设计与样本

  • 研究纳入901例在3个月内使用同一设备接受胸部CT和心电门控非增强心脏CT的患者,以手工法从心脏CT数据获得的CACS为标准,AI-CACS软件基于深度学习算法,用来自胸部CT数据库的多厂商、多扫描仪、多医院匿名数据训练,从胸部CT数据自动获得AI-CACS。

诊断标准与关键数值

  • AI-CACS与手工CACS相关性ρ=0.893(p<0.001),Bland-Altman图(AI-CACS减手工CACS)平均差异-27.2,95%一致性界限-290.0至235.6;风险分类一致性κ=0.679(p<0.001),一致率80.6%;以0、100、400为二分界值时,AI-CACS的准确率分别为88.6%、92.9%、97.9%,κ值分别为0.77、0.77、0.83,AUC分别为0.885、0.964、0.981。

临床应用与阅片要点

  • 原文结论认为基于非门控胸部CT数据用AI软件可在短时间内获得CACS而不增加辐射剂量或经济负担,且算法具有良好临床普适性,可应用于不同厂商的CT机型。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the risk category performance of artificial intelligence-based coronary artery calcium score (AI-CACS) software used in non-gated chest computed tomography (CT) on three types of CT machines, considering the manual method as the standard.

METHODS: A total of 901 patients who underwent both chest CT and electrocardiogram (ECG)-gated non-contrast-enhanced cardiac CT with the same equipment within a 3-month period were enrolled in the study. AI-CACS software was based on a deep learning algorithm and was trained on multi-vendor, multi-scanner, and multi-hospital anonymized data from the chest CT database. The AI-CACS was automatically obtained from chest CT data by the AI-CACS software, while the manual CACS was obtained from cardiac CT data by the manual method. The correlation of the AI-CACS and manual CACS, concordance rate and kappa value of the risk categories determined by the two methods were calculated. The chi-square test was used to evaluate the differences in risk categories among the three types of CT machines from different manufacturers. The risk category performance of the AI-CACS for dichotomous risk categories bounded by 0, 100 and 400 was assessed.

RESULTS: The correlation of the AI-CACS with the manual CACS was ρ = 0.893 (p < 0.001). The Bland-Altman plot (AI-CACS minus manual CACS) showed a mean difference of -27.2 and 95% limits of agreement of -290.0 to 235.6. The agreement of risk categories for the CACS was kappa (κ) = 0.679 (p < 0.001), and the concordance rate was 80.6%. The risk categories determined by the AI-CACS software on three types of CT machines were not significantly different (p = 0.7543). As dichotomous risk categories bounded by 0, 100 and 400, the accuracy, kappa value, and area under the curve of the AI-CACS were 88.6% vs. 92.9% vs. 97.9%, 0.77 vs. 0.77 vs. 0.83, and 0.885 vs. 0.964 vs. 0.981, respectively.

CONCLUSIONS: There was good correlation and agreement between the AI-CACS and manual CACS in terms of the risk category. It is feasible to obtain the CACS using AI software based on non-gated chest CT data in a short time without increasing the radiation dose or economic burden. The AI-CACS software algorithm has good clinical universality and can be applied to CT machines from different manufacturers.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Xu, Liu, Guo, et al. Performance of artificial intelligence-based coronary artery calcium scoring in non-gated chest CT. Eur J Radiol. 2021. PMID: 34837795. doi:10.1016/j.ejrad.2021.110034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。