文献速递骨肌MR

常规磁共振成像按照Yoo和Rhee分类系统在肩关节镜肩袖手术患者中检测和分级肩胛下肌腱撕裂的诊断效能

Diagnostic performance of conventional magnetic resonance imaging for detection and grading of subscapularis tendon tear according to Yoo and Rhee classification system in patients underwent arthroscopic rotator cuff surgery.
PubMed 文献 · Skeletal Radiol · 2021-11-26

本研究纳入179例接受MRI后行关节镜肩袖手术的患者,由两名肌骨放射科医师按Yoo和Rhee分类评估肩胛下肌腱撕裂,以关节镜所见为参考标准。常规MRI检测IIA级及以上撕裂的平均准确率为82.5%,检测IIB级及以上(手术候选)撕裂的平均准确率为78.5%,分级观察者间一致性极好(κ=0.86)。

要点

  • 常规MRI检测肩胛下肌腱撕裂(IIA级及以上)的敏感度85%-89%、特异度70%-75%、准确率82%-83%。
  • 检测需手术的撕裂(IIB级及以上)敏感度均为77%,特异度75%-83%,准确率75%-82%。
  • 分级观察者间一致性极好(κ=0.86),撕裂存在与手术候选组的一致性均为显著(κ=0.70、0.68)。

核心结论

  • 常规MRI应用Yoo和Rhee分类诊断肩胛下肌腱撕裂,检测IIA级及以上和IIB级及以上撕裂的平均准确率分别为82.5%和78.5%,分级观察者间一致性极好。

研究设计与样本

  • 共纳入179例接受MRI后行关节镜肩袖手术的患者,两名肌骨放射科医师依据Yoo和Rhee分类在轴位、斜矢状位和斜冠状位MRI上评估肩胛下肌腱,以关节镜所见为参考标准。

诊断标准与关键数值

  • 关节镜证实I型35例、IIA型70例、IIB型35例、III型9例、IV型9例、V型0例。
  • 读者1检测撕裂(IIA级及以上)的敏感度85%、特异度75%、准确率82%;读者2分别为89%、70%、83%。
  • 读者1检测手术候选(IIB级及以上)的敏感度77%、特异度75%、准确率75%;读者2分别为77%、83%、82%。
  • 检测肩胛下肌腱撕裂存在的观察者间一致性为显著(κ=0.70),检测手术候选组为显著(κ=0.68),分级为极好(κ=0.86)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the diagnostic accuracy of conventional MRI for detecting and grading subscapularis (SSC) tears by applying the Yoo and Rhee classification.

MATERIALS AND METHODS: A total of 179 patients who underwent MRI followed by arthroscopic rotator cuff surgery were enrolled. Two musculoskeletal radiologists evaluated the SSC using axial, oblique sagittal, and oblique coronal MRI according to the Yoo and Rhee classification. Using arthroscopic findings as the reference standard, the sensitivity, specificity, accuracy, and interobserver agreement of SSC tears were analyzed.

RESULTS: Arthroscopy confirmed that the numbers of type I, IIA, IIB, III, IV, and V tears were 35, 70, 35, 9, 9, and 0, respectively. The sensitivity, specificity, and accuracy of readers 1 and 2 for the detection of tears (type IIA or higher) were 85%, 75%, and 82%, and 89%, 70%, and 83%, respectively, while those for the detection of surgical candidates (type IIB or higher) were 77%, 75%, and 75%, and 77%, 83%, and 82%, respectively. The interobserver agreement for detecting SSC tear presence was substantial (κ = 0.70) for reader 1 vs. reader 2, and those for detecting the surgical candidate group was substantial (κ = 0.68) for reader 1 vs. reader 2. The interobserver agreement for grading SSC tears was excellent (κ = 0.86) for reader 1 vs. reader 2.

CONCLUSION: Conventional MRI showed 82.5% and 78.5% average accuracy in detecting IIA and IIB or higher tears by applying the Yoo and Rhee classification for the diagnosis of SSC tears with an excellent interobserver agreement in tear grading.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Ahn, Yoon, Yoo, et al. Diagnostic performance of conventional magnetic resonance imaging for detection and grading of subscapularis tendon tear according to Yoo and Rhee classification system in patients underwent arthroscopic rotator cuff surgery. Skeletal Radiol. 2021. PMID: 34825259. doi:10.1007/s00256-021-03958-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。