101种非冠状动脉透视引导介入操作的辐射暴露:参考点空气比释动能与空气比释动能面积积的参考水平
该回顾性研究纳入美国一家大型三级医院放射科2016年5月至2018年10月连续非冠状动脉透视引导介入操作,基于24,911例次分析,给出101种操作的参考点空气比释动能、空气比释动能面积积和透视时间的中位数与第75百分位数,作为剂量优化研究的基准参考水平。
要点
- 研究给出101种非冠状动脉透视引导介入操作的辐射剂量参考水平(中位数与第75百分位数)。
- 参考指标包括参考点空气比释动能、空气比释动能面积积和透视时间。
- 其中至少50种操作的上述四分位数系首次报告。
核心结论
- 本研究为涵盖诊断、靶向微创介入和治疗性治疗的101种透视引导介入操作提供了参考水平(第50和第75百分位数),反映最新透视引导介入研究的整体情况。
研究设计与样本
- 回顾性研究,纳入美国一家大型三级医院放射科2016年5月至2018年10月连续非冠状动脉透视引导介入操作,基于24,911例次分析,按操作类型分类,使用与口述系统集成的院内半自动软件记录参考点空气比释动能、空气比释动能面积积和透视时间,采用R软件(v. 3.5.1,R Foundation)计算各操作类型的辐射暴露四分位数。
诊断标准与关键数值
- 对101种操作分别给出参考点空气比释动能、空气比释动能面积积和透视时间的中位数与第75百分位数作为参考水平,其中至少50种操作的上述四分位数系首次报告。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To present the median value and 75th percentile of air kerma at the reference point (Ka,r), air kerma-area product (KAP), and fluoroscopic time for a large number of fluoroscopically guided interventional (FGI) procedures.
METHODS: This retrospective study included the consecutive non-coronary FGI procedures from a Radiology department between May 2016 and October 2018 at a large tertiary-care hospital in the U.S. An in-house developed, semi-automated software, integrated with a dictation system, was used to record patient examination information, including Ka,r, KAP and fluoroscopic time. The included patient procedures were categorized into procedure types. A software package R (v. 3.5.1, R Foundation) was used to calculate procedure-specific quartiles of radiation exposure.
RESULTS: Based on analysis of 24,911 FGI cases, median value and 75th percentile are presented for each of Ka,r, KAP and fluoroscopic time for 101 procedures that can act as benchmark for comparison for dose optimization studies.
CONCLUSION: This study provides reference levels ( 50th and 75th percentiles) for a comprehensive list of FGI procedures, reflecting an overall picture of the latest FGI studies for diagnosis, targeted minimally invasive intervention, and therapeutic treatment.
ADVANCES IN KNOWLEDGE: This study provides reference levels (50th and 75th percentiles) for the largest number of fluoroscopically guided interventional procedures reported to date (101 procedures), in terms of air kerma at the reference point, air kerma-area product, and fluoroscopic time, among which these quartiles for ≥50 procedures are presented for the first time.
引用
- Li, Hirsch, Rehani, et al. Radiation exposure in 101 non-coronary fluoroscopically guided interventional procedures: reference levels of air kerma at the reference point and air kerma area product. Br J Radiol. 2021. PMID: 34826249. doi:10.1259/bjr.20211108
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。