文献速递神经儿科影像MR

3.0特斯拉磁共振扫描仪中孕晚期胎儿脑的正常弥散度

3.0 Tesla normative diffusivity in 3rd trimester fetal brain.
PubMed 文献 · Neuroradiology · 2021-11-25

在47例超声正常或可疑异常而结构MRI正常的单胎胎儿中,于3.0T扫描仪行DWI并测量额叶、顶叶、颞叶、基底节和脑桥的ADC值,中位孕龄30.1周(范围26-34周)。ADC值以脑叶最高(顶叶>额叶>颞叶),基底节较低,脑桥最低;基底节和脑桥ADC值随孕龄增加而下降,脑叶ADC值在本队列中保持稳定。3.0T的脑区ADC值与既往1.5T报道值可比,随孕龄变化趋势相似。

要点

  • 3.0T胎儿脑ADC值以脑叶最高,顶叶>额叶>颞叶,基底节次之,脑桥最低。
  • 基底节和脑桥ADC值随孕龄增加而下降,额叶、顶叶、颞叶ADC值在26-34周保持稳定。
  • 3.0T胎儿脑ADC值与既往1.5T报道值可比,随孕龄变化趋势相似。

核心结论

  • 3.0T扫描仪的区域脑ADC值与既往1.5T扫描仪报道值可比,随孕龄变化趋势相似。

研究设计与样本

  • 在47例超声正常或可疑异常、随后结构MRI正常的单胎胎儿中行DWI并测量ADC值,中位孕龄30.1周(范围26-34周)。

关键影像表现/征象

  • ADC值在脑叶最高(顶叶>额叶>颞叶),基底节较低,脑桥最低。
  • 基底节和脑桥ADC值随孕龄增加而下降。
  • 额叶、顶叶和颞叶ADC值在本队列中保持稳定。

诊断标准与关键数值

  • 在3.0T扫描仪测量额叶、顶叶、颞叶、基底节和脑桥的ADC值,区域对ADC值有显著影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Apparent diffusion coefficient (ADC) values in the developing fetus provide valuable information on the diagnosis and prognosis of prenatal brain pathologies. Normative ADC data has been previously established in 1.5 T MR scanners but lacking in 3.0 T scanners. Our objective was to measure ADC values in various brain areas in a cohort of normal singleton fetuses scanned in a 3.0 T MR scanner.

METHODS: DWI (diffusion-weighted imaging) was performed in 47 singleton fetuses with normal or questionably abnormal results on sonography followed by normal structural MR imaging. ADC values were measured in cerebral lobes (frontal, parietal, temporal lobes), basal ganglia, and pons. Regression analysis was used to examine gestational age-related changes in regional ADC.

RESULTS: Median gestational age was 30.1 weeks (range, 26-34 weeks). There was a significant effect of region on ADC values, whereby ADC values were highest in cerebral lobes (parietal > frontal > temporal lobes), compared with basal ganglia. The lowest values were found in the pons. On regression analysis, there was a decrease in ADC values in basal ganglia and pons with increasing gestational age. ADC values in frontal, parietal, and temporal lobes were stable in our cohort.

CONCLUSION: Regional brain ADC values in 3.0 T scanners are comparable with previously reported values in 1.5 T scanners, with similar changes over gestational age. Using 3.0 T scanners is increasing worldwide. For fetal imaging, establishing normal ADC values is critical as DWI enables a sensitive and quantitative technique to evaluate normal and abnormal brain development.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Segev, Djurabayev, Katorza, et al. 3.0 Tesla normative diffusivity in 3rd trimester fetal brain. Neuroradiology. 2021. PMID: 34820712. doi:10.1007/s00234-021-02863-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。