文献速递乳腺乳腺X线

数字乳腺断层摄影与数字乳腺X线摄影评估乳腺密度的比较:乳腺癌症监测联盟

Comparing Mammographic Density Assessed by Digital Breast Tomosynthesis or Digital Mammography: The Breast Cancer Surveillance Consortium.
PubMed 文献 · Radiology · 2021-11-23

该前瞻性队列研究二次分析纳入40-79岁接受数字乳腺X线摄影(DM)或数字乳腺断层摄影(DBT)筛查的女性,评估BI-RADS乳腺密度报告的一致性及密度作为乳腺癌风险因素的效应。共分析403 326对乳腺影像,DM与DBT混合对、两DM对、两DBT对的密度评估一致率分别为77%、79%、77%,κ值分别为0.64、0.67、0.65,无显著差异;DM与DBT评估的密度风险比相似(交互作用P=0.45)。结论认为放射科医生基于DBT与DM报告的BI-RADS密度无差异。

要点

  • DBT与DM报告的BI-RADS乳腺密度一致率与重复DM检查相当,κ值0.64-0.67。
  • 乳腺密度作为乳腺癌风险因素的HR在DM与DBT间无显著交互作用(P=0.45)。
  • 日常阅片中DBT的密度报告可直接沿用DM的BI-RADS密度分类经验。

核心结论

  • 放射科医生使用DBT获得的BI-RADS密度报告与使用DM获得的报告无差异,且密度作为乳腺癌风险因素的效应在两种检查间相似。

研究设计与样本

  • 乳腺癌症监测联盟前瞻性队列研究的二次分析,纳入40-79岁、两次筛查乳腺摄影间隔小于36个月、接受DM或DBT的女性,共分析403 326对乳腺影像(来自342 149名女性);采用Cox比例风险回归计算侵袭性乳腺癌的风险比(HR)。

诊断标准与关键数值

  • DM与DBT混合对(57 516/74 729)的BI-RADS密度评估一致率为77%,κ=0.64。
  • 两DM对(238 678/301 743)的BI-RADS密度评估一致率为79%,κ=0.67。
  • 两DBT对(20 763/26 854)的BI-RADS密度评估一致率为77%,κ=0.65。
  • 限制为同一放射科医生阅片时结果相似。
  • DM与DBT的密度HR交互作用P=0.45;几乎全脂肪HR分别为0.55(95%CI:0.49,0.63)与0.37(95%CI:0.21,0.66),不均匀致密HR分别为1.47(95%CI:1.37,1.58)与1.36(95%CI:1.02,1.82),极度致密HR分别为1.72(95%CI:1.54,1.93)与2.05(95%CI:1.25,3.36)。

临床应用与阅片要点

  • 基于DBT筛查的BI-RADS密度报告可与DM报告同等用于乳腺癌风险评估和补充筛查决策。
  • 同一放射科医生阅片时DM与DBT密度报告一致性相似,提示阅片者内部一致性不受检查方式显著影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Consistency in reporting Breast Imaging Reporting and Data System (BI-RADS) breast density on mammograms is important because breast density is used for breast cancer risk assessment and is reported directly to women and clinicians to inform decisions about supplemental screening. Purpose To assess the consistency of BI-RADS density reporting between digital breast tomosynthesis (DBT) and digital mammography (DM) and evaluate density as a breast cancer risk factor when assessed using DM versus DBT. Materials and Methods The Breast Cancer Surveillance Consortium is a prospective cohort study of women undergoing mammography with DM or DBT. This secondary analysis included women aged 40-79 years who underwent at least two screening mammography examinations less than 36 months apart. Percentage agreement and κ statistic were estimated for pairs of BI-RADS density assessments. Cox proportional hazards regression was used to calculate hazard ratios (HRs) of breast density as a risk factor for invasive breast cancer. Results A total of 403 326 pairs of mammograms from 342 149 women were evaluated. There were no significant differences in breast density assessment in pairs consisting of one DM and one DBT examination (57 516 of 74 729 [77%]; κ = 0.64), two DM examinations (238 678 of 301 743 [79%]; κ = 0.67), and two DBT examinations (20 763 of 26 854 [77%]; κ = 0.65). Results were similar when restricting the analyses to pairs read by the same radiologist. The breast cancer HRs for breast density were similar for DM and DBT (P = .45 for interaction). The HRs for density acquired using DM and DBT, respectively, were 0.55 (95% CI: 0.49, 0.63) and 0.37 (95% CI: 0.21, 0.66) for almost entirely fat, 1.47 (95% CI: 1.37, 1.58) and 1.36 (95% CI: 1.02, 1.82) for heterogeneously dense, and 1.72 (95% CI: 1.54, 1.93) and 2.05 (95% CI: 1.25, 3.36) for extremely dense breasts. Conclusion Radiologist reporting of Breast Imaging Reporting and Data System density obtained with digital breast tomosynthesis did not differ from that obtained with digital mammography. © RSNA, 2021 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Tice, Gard, Miglioretti, et al. Comparing Mammographic Density Assessed by Digital Breast Tomosynthesis or Digital Mammography: The Breast Cancer Surveillance Consortium. Radiology. 2021. PMID: 34812671. doi:10.1148/radiol.2021204579

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。