文献速递神经CT

24小时非增强CT上缺血性病灶体积手动分割的变异性评估

Variability assessment of manual segmentations of ischemic lesion volume on 24-h non-contrast CT.
PubMed 文献 · Neuroradiology · 2021-11-23

本研究从Prove-IT研究中随机选取50例患者,由三名评估者在24小时非增强CT上逐层手动分割缺血性病灶体积各三次,以STAPLE算法生成的参考标准评估评估者间与评估者内信度。结果显示评估者间ICC为0.83(95%CI 0.76-0.88),评估者内ICC为0.85-0.95,平均总体DSC为72.8±23.0%。结论认为尽管存在一定变异性,随访CT上的手动缺血性病灶体积测量作为影像学结局指标是可靠的。

要点

  • 三名评估者手动分割的缺血性病灶体积均值范围为88.2±91.5至135.5±119.9 ml。
  • 评估者间ICC为0.83(95%CI 0.76-0.88),评估者内ICC为0.85至0.95。
  • 三名评估者间平均DSC范围为65.5±22.9%至76.4±17.1%,平均总体DSC为72.8±23.0%。

核心结论

  • 随访CT上的手动缺血性病灶体积测量尽管存在一定变异性,但作为影像学结局指标是可靠的。

研究设计与样本

  • 从Prove-IT研究中随机选取50例患者,三名评估者在24小时非增强CT上逐层手动分割缺血性病灶体积各三次,以STAPLE算法生成的缺血性病灶体积为参考标准。

诊断标准与关键数值

  • 评估者间ICC为0.83(95%CI 0.76-0.88)。
  • 评估者内ICC范围为0.85(95%CI 0.72-0.92)至0.95(95%CI 0.91-0.97)。
  • 三名评估者间平均DSC范围为65.5±22.9%至76.4±17.1%,平均总体DSC为72.8±23.0%。
  • 参考标准平均缺血性病灶体积为92.5 ml(SD±100.9 ml),手动分割缺血性病灶体积范围为88.2±91.5至135.5±119.9 ml。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Infarct lesion volume (ILV) may serve as an imaging biomarker for clinical outcomes in the early post-treatment stage in patients with acute ischemic stroke. The aim of this study was to evaluate the inter- and intra-rater reliability of manual segmentation of ILV on follow-up non-contrast CT (NCCT) scans.

METHODS: Fifty patients from the Prove-IT study were randomly selected for this analysis. Three raters manually segmented ILV on 24-h NCCT scans, slice by slice, three times. The reference standard for ILV was generated by the Simultaneous Truth And Performance Level estimation (STAPLE) algorithm. Intra- and inter-rater reliability was evaluated, using metrics of intraclass correlation coefficient (ICC) regarding lesion volume and the Dice similarity coefficient (DSC).

RESULTS: Median age of the 50 subjects included was 74.5 years (interquartile range [IQR] 67-80), 54% were women, median baseline National Institutes of Health Stroke Scale was 18 (IQR 11-22), median baseline ASPECTS was 9 (IQR 6-10). The mean reference standard ILV was 92.5 ml (standard deviation (SD) ± 100.9 ml). The manually segmented ILV ranged from 88.2 ± 91.5 to 135.5 ± 119.9 ml (means referring to the variation between readers, SD within readers). Inter-rater ICC was 0.83 (95%CI: 0.76-0.88); intra-rater ICC ranged from 0.85 (95%CI: 0.72-0.92) to 0.95 (95%CI: 0.91-0.97). The mean DSC among the three readers ranged from 65.5 ± 22.9 to 76.4 ± 17.1% and the mean overall DSC was 72.8 ± 23.0%.

CONCLUSION: Manual ILV measurements on follow-up CT scans are reliable to measure the radiological outcome despite some variability.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Cimflova, Ospel, Marko, et al. Variability assessment of manual segmentations of ischemic lesion volume on 24-h non-contrast CT. Neuroradiology. 2021. PMID: 34812917. doi:10.1007/s00234-021-02855-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。