MRI评估幼年特发性关节炎儿童颞下颌关节关节炎:新制定评分系统的可重复性
研究基于挪威NorJIA研究86例受试者的MRI数据集,由两名有经验放射科医生评估颞下颌关节25项影像特征,以Cohen线性或加权Kappa及Bland-Altman 95%一致性界限衡量观察者间与观察者内一致性。骨软骨域6项序数变量和炎症域4项序数变量Kappa均高于0.5,连续测量一致性差、一致性界限宽。作者提出由骨软骨域7项变量和炎症域4项变量组成的MRI评分系统,并指出需进一步检验其临床有效性。
要点
- 骨软骨域「髁突体积丢失」「髁突形态」「髁突不规则」「关节结节/窝形态」「关节盘异常」「髁突倾斜度」观察者间与观察者内Kappa均高于0.5。
- 炎症域「关节液」「炎症总体印象」「滑膜强化」「骨髓水肿」观察者间与观察者内Kappa均高于0.5。
- 连续测量一致性差、一致性界限宽,作者提出含骨软骨域7项和炎症域4项变量的评分系统。
核心结论
- 作者提出一个用于评估幼年特发性关节炎患儿颞下颌关节的MRI评分系统,由骨软骨域7项变量和炎症域4项变量组成,并指出需进一步检验这些变量的临床有效性。
研究设计与样本
- 基于挪威幼年特发性关节炎研究(NorJIA研究)的临床数据与影像,86例受试者的颞下颌关节MRI数据集由两名有经验放射科医生评估25项影像特征的观察者间与观察者内一致性。
诊断标准与关键数值
- 序数变量一致性用Cohen线性或加权Kappa衡量,连续测量用Bland-Altman 95%一致性界限评估;骨软骨域「髁突体积丢失」「髁突形态」「髁突不规则」「关节结节/窝形态」「关节盘异常」「髁突倾斜度」及炎症域「关节液」「炎症总体印象」「滑膜强化」「骨髓水肿」观察者间与观察者内Kappa均高于0.5。
临床应用与阅片要点
- 作者提出由骨软骨域7项变量和炎症域4项变量组成的MRI评分系统,其中骨软骨域6项序数变量与炎症域4项序数变量观察者间和观察者内Kappa均高于0.5。
局限性
- 原文指出需进一步检验这些变量的临床有效性。
- 连续测量一致性差、一致性界限宽。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The temporomandibular joint (TMJ) is commonly involved in children with juvenile idiopathic arthritis. The diagnosis and evaluation of the disease progression is dependent on medical imaging. The precision of this imaging is under debate. Several scoring systems have been proposed but transparent testing of the precision of the constituents of the scoring systems is lacking. The present study aims to test the precision of 25 imaging features based on magnetic resonance imaging (MRI).
MATERIALS AND METHODS: Clinical data and imaging were obtained from the Norwegian juvenile idiopathic arthritis study, The NorJIA study. Twenty-five imaging features of the TMJ in MRI datasets from 86 study participants were evaluated by two experienced radiologists for inter- and intraobserver agreement. Agreement of ordinal variables was measured with Cohen´s linear or weighted Kappa as appropriate. Agreement of continuous measurements was assessed with 95% limit of agreement according to Bland-Altman.
RESULTS: In the osteochondral domain, the ordinal imaging variables "loss of condylar volume," "condylar shape," "condylar irregularities," "shape of the eminence/fossa," "disk abnormalities," and "condylar inclination" showed inter- and intraobserver agreement above Kappa 0.5. In the inflammatory domain, the ordinal imaging variables "joint fluid," "overall impression of inflammation," "synovial enhancement" and "bone marrow oedema" showed inter- and intraobserver agreement above Kappa 0.5. Continuous measurements performed poorly with wide limits of agreement.
CONCLUSION: A precise MRI-based scoring system for assessment of TMJ in JIA is proposed consisting of seven variables in the osteochondral domain and four variables in the inflammatory domain. Further testing of the clinical validity of the variables is needed.
引用
- Angenete, Augdal, Rygg, et al. MRI in the Assessment of TMJ-Arthritis in Children with JIA; Repeatability of a Newly Devised Scoring System. Acad Radiol. 2021. PMID: 34802906. doi:10.1016/j.acra.2021.09.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。