文献速递腹部CTMR

临床实践中报告的LI-RADS 5类观察中有多少不符合LI-RADS 5类标准

What proportion of LI-RADS 5 observations reported in clinical practice do not meet LI-RADS 5 criteria?
PubMed 文献 · Eur Radiol · 2021-11-22

该回顾性研究分析了2017年4月至2020年9月使用标准化LI-RADS模板的MR和CT报告,共308个报告为LR-5的观察(234例患者)。基于报告的主要影像特征,按所用LI-RADS版本判定,v2017有6%(8/136)、v2018有3%(6/172)的LR-5观察不符合LR-5标准;最常见错误是缺乏非环状动脉期高强化。

要点

  • 临床实践中3-6%的LR-5报告基于主要影像特征不符合LR-5标准。
  • 缺乏非环状动脉期高强化是最常见的LR-5误分类原因。
  • v2017误分类中43%为10-19mm伴APHE和WO,v2018误分类中83%缺乏APHE。

核心结论

  • 根据LI-RADS版本不同,临床实践中3-6%的LR-5观察基于报告的主要影像特征不符合LR-5标准。

研究设计与样本

  • 回顾性研究,纳入2017年4月至2020年9月使用标准化LI-RADS模板的MR和CT报告,共308个LR-5观察(234例患者,67.6%男性,平均年龄66.2岁),以报告的主要影像特征按所用LI-RADS版本判定是否符合LR-5标准。

关键影像表现/征象

  • v2017的136个LR-5观察中8个(6%)不符合LR-5标准。
  • v2018的172个LR-5观察中6个(3%)不符合LR-5标准。
  • v2017的8个误分类观察中,3个(43%)缺乏动脉期高强化,1个(14%)为16mm新发观察仅伴动脉期高强化,4个(43%)为10-19mm伴动脉期高强化和廓清。
  • v2018的6个误分类观察中,5个(83%)缺乏动脉期高强化,1个(17%)小于10mm。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Liver Imaging Reporting and Data System (LI-RADS, LR) category 5 (definite hepatocellular carcinoma [HCC]) is assigned based on combinations of major imaging features (MFs): size, arterial-phase hyperenhancement (APHE), washout (WO), enhancing capsule, and threshold growth. The criteria were simplified in v2018 compared to v2017. The goal of this study is to assess the proportion of LR-5 observations reported in clinical practice with LI-RADS v2017 or v2018 that did not meet LR-5 criteria based on reported MFs.

METHODS: All MR and CT reports using a standardized LI-RADS template between April 2017 and September 2020 were identified retrospectively. For each reported LR-5 observation, size, MFs, and LI-RADS version (v2017 or v2018) were extracted. Reported MFs were used to determine whether LR-5 criteria were met using the applied version of LI-RADS. The data was summarized descriptively.

RESULTS: Three hundred eight observations in 234 patients (67.6% male, mean age 66.2 years) were reported as LR-5, including 136 (44.2%) with v2017 and 172 (55.8%) with v2018. 8/136 (6%) v2017 LR-5 observations and 6/172 (3%) v2018 LR-5 observations did not meet LR-5 criteria. Of 8 incorrectly categorized v2017 observations, 3 (43%) lacked APHE, 1 (14%) was a 16-mm new observation with APHE only, and 4 (43%) were 10-19 mm with APHE and WO. Of the 6 incorrectly categorized v2018 observations, 5 (83%) lacked APHE and 1 (17%) was < 10 mm.

CONCLUSIONS: Depending on the LI-RADS version, 3-6% of LR-5 observations reported in clinical practice do not meet LR-5 criteria based on reported MFs. Key Points • Depending on the LI-RADS version, 3-6% of LR-5 observations in clinical practice do not meet LR-5 criteria based on reported major imaging features. • Assigning LR-5 category to observations without nonrim arterial-phase hyperenhancement was the most common error.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ghadimi, Birnbaum, Kamel, et al. What proportion of LI-RADS 5 observations reported in clinical practice do not meet LI-RADS 5 criteria? Eur Radiol. 2021. PMID: 34807269. doi:10.1007/s00330-021-08389-5