文献速递胸部技术与安全CT

人工智能工具并行使用对放射科医生阅片时间的影响:一项前瞻性可行性研究

Impact of Concurrent Use of Artificial Intelligence Tools on Radiologists Reading Time: A Prospective Feasibility Study.
PubMed 文献 · Acad Radiol · 2021-11-17

该前瞻性可行性研究于2020年4月至5月将AI工具嵌入非增强胸部CT的PACS阅片流程,由外部观察者记录1名顾问放射科医生和1名放射科住院医师在有/无AI辅助下的阅片时间。住院医师无AI 370s vs 有AI 437s(+67s,95%CI -28s至+163s,p=0.16),顾问无AI 366s vs 有AI 380s(+13s,95%CI -57s至84s,p=0.70),均无显著差异;AI带来5/40(12.5%)例额外可操作发现,住院医师90%(18/20)例感知病例概览更好。

要点

  • AI辅助阅片未显著增加住院医师阅片时间(370s vs 437s,p=0.16)和顾问阅片时间(366s vs 380s,p=0.70)。
  • AI工具在5/40(12.5%)例中带来额外可操作发现。
  • 住院医师在18/20(90%)例中感知病例概览更好。

核心结论

  • 基于PACS的AI工具并行阅读胸部CT未增加阅片时间,同时产生额外可操作发现并使住院医师感知病例概览更好。

研究设计与样本

  • 前瞻性可行性研究,将AI工具于2020年4月至5月实施于非增强胸部CT的PACS阅片流程,由外部观察者记录1名顾问放射科医生和1名放射科住院医师的阅片时间,每位读者无AI 25例、有AI 20例。

诊断标准与关键数值

  • 采用Welch t检验进行非劣效性检验,非劣效界值定义为顾问100秒、住院医师200秒。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONAL AND OBJECTIVES: This study investigated how an AI tool impacted radiologists reading time for non-contrast chest CT exams.

MATERIALS AND METHODS: An AI tool was implemented into the PACS reading workflow of non-contrast chest CT exams between April and May 2020. The reading time was recorded for one CONSULTANT RADIOLOGIST and one RADIOLOGY RESIDENT by an external observer. After each case radiologists answered questions regarding additional findings and perceived case overview. Reading times were recorded for 25 cases without and 20 cases with AI tool assistance for each reader. Differences in reading time with and without the AI tool were assessed using Welch's t-test for non-inferiority with non-inferiority limits defined as 100 seconds for the consultant and 200 seconds for the resident.

RESULTS: The mean reading time for the radiology resident was not significantly affected by the AI tool (without AI 370s vs with AI 437s; +67s 95% CI -28s to +163s, p = 0.16). The reading time for the radiology consultant was also not significantly affected by the AI tool (without AI 366s vs with AI 380s; +13s (95% CI - -57s to 84s, p = 0.70). The AI tool led to additional actionable findings in 5/40 (12.5%) studies and better overview in 18/20 (90%) of studies for the resident.

CONCLUSION: A PACS based implementation of an AI tool for concurrent reading of chest CT exams did not increase reading time with additional actionable findings made as well as a perceived better case overview for the radiology resident.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Müller, Raaschou, Akhtar, et al. Impact of Concurrent Use of Artificial Intelligence Tools on Radiologists Reading Time: A Prospective Feasibility Study. Acad Radiol. 2021. PMID: 34801345. doi:10.1016/j.acra.2021.10.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。