文献速递心血管外周血管MRCT

壁面剪切应力预测二叶式主动脉瓣患者的主动脉扩张

Wall Shear Stress Predicts Aortic Dilation in Patients With Bicuspid Aortic Valve.
PubMed 文献 · JACC Cardiovasc Imaging · 2021-11-17

本研究前瞻性纳入47例无瓣膜功能障碍的二叶式主动脉瓣患者,用4D flow心脏磁共振计算壁面剪切应力(WSS),并以随访CT血管造影评估升主动脉生长率。中位随访43个月,升主动脉中段生长率为0.24 mm/年,WSS及其周向分量与生长率独立相关,提示WSS可用于预测主动脉扩张。

要点

  • 二叶式主动脉瓣患者升主动脉中段生长率中位为0.24 mm/年,生长呈不均匀分布。
  • WSS及周向WSS与升主动脉中段生长率独立相关,周向分量关联更强。
  • 在生长最快区域,周向WSS而非WSS幅值与生长率呈正相关。

核心结论

  • 4D flow心脏磁共振衍生的WSS、尤其是其周向分量,可预测二叶式主动脉瓣患者升主动脉的进行性扩张;作者认为随访中可考虑评估WSS。

研究设计与样本

  • 前瞻性研究,纳入47例无瓣膜功能障碍的二叶式主动脉瓣患者,行4D flow心脏磁共振计算WSS,并随访2次心电图门控高分辨率增强CT血管造影评估生长率。

关键影像表现/征象

  • 升主动脉生长率在升主动脉内呈不均匀分布,生长最快区域与周向WSS正相关。

诊断标准与关键数值

  • WSS与升主动脉中段生长率双变量分析P=0.049,校正每搏输出量和基线升主动脉直径后多变量分析P=0.046,校正z-score后P=0.036。
  • 周向WSS与升主动脉中段生长率双变量分析P=0.014,校正每搏输出量和基线升主动脉直径后多变量分析P=0.014,校正z-score后P=0.012。

临床应用与阅片要点

  • 作者认为,二叶式主动脉瓣患者随访中可考虑评估WSS。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study sought to assess the predictive value of wall shear stress (WSS) for colocalized ascending aorta (AAo) growth rate (GR) in patients with bicuspid aortic valve (BAV).

BACKGROUND: BAV is associated with AAo dilation, but there is limited knowledge about possible predictors of aortic dilation in patients with BAV. An increased WSS has been related to aortic wall damage in patients with BAV, but no previous prospective study tested its predictive value for dilation rate. Recently, a registration-based technique for the semiautomatic mapping of aortic GR has been presented and validated.

METHODS: Forty-seven patients with BAV free from valvular dysfunction prospectively underwent 4-dimensional flow cardiac magnetic resonance to compute WSS and subsequent follow-up with 2 electrocardiogram-gated high-resolution contrast-enhanced computed tomography angiograms for GR assessment.

RESULTS: During a median follow-up duration of 43 months, mid AAo GR was 0.24 mm/year. WSS and its circumferential component showed statistically significant association with mid AAo GR in bivariate (P = 0.049 and P = 0.014, respectively) and in multivariate analysis corrected for stroke volume and either baseline AAo diameter (P = 0.046 and P = 0.014, respectively) or z-score (P = 0.036 and P = 0.012, respectively). GR mapping further detailed that GR was heterogeneous in the AAo and that circumferential WSS, but not WSS magnitude, showed statistically significant positive associations with GR in the regions with the fastest growth.

CONCLUSIONS: 4D flow cardiac magnetic resonance-derived WSS and, in particular, its circumferential component predict progressive dilation of the ascending aorta in patients with BAV. Thus, the assessment of WSS may be considered in the follow-up of these patients.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Guala, Dux-Santoy, Teixido-Tura, et al. Wall Shear Stress Predicts Aortic Dilation in Patients With Bicuspid Aortic Valve. JACC Cardiovasc Imaging. 2021. PMID: 34801463. doi:10.1016/j.jcmg.2021.09.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。