文献速递乳腺甲状腺与浅表US

乳腺癌患者腋窝前哨淋巴结转移术前诊断中淋巴造影增强超声与静脉增强超声的比较

Comparison of lymphatic contrast-enhanced ultrasound and intravenous contrast-enhanced ultrasound in the preoperative diagnosis of axillary sentinel lymph node metastasis in patients with breast cancer.
PubMed 文献 · Br J Radiol · 2021-11-29

该研究纳入69例乳腺癌患者,术前均行淋巴造影增强超声(LCEUS)和静脉增强超声(ICEUS),分析每例患者一枚前哨淋巴结的增强模式,以术中钢丝定位切除后的组织病理为参考标准。LCEUS、ICEUS及两者联合的敏感度分别为86.2%、82.6%、93.1%,特异度分别为95.0%、92.5%、87.5%,准确率分别为91.3%、88.4%、89.9%。LCEUS的ROC曲线下面积为0.906,三种方法间无显著差异(p=0.752)。结论提示LCEUS可能是一种术前预测前哨淋巴结转移的准确方法,在LCEUS基础上加做ICEUS似乎不必要。

要点

  • LCEUS诊断腋窝前哨淋巴结转移的敏感度86.2%、特异度95.0%、准确率91.3%。
  • LCEUS、ICEUS及两者联合的ROC曲线下面积无显著差异(p=0.752)。
  • 在LCEUS基础上加做ICEUS似乎不必要。

核心结论

  • LCEUS可能是一种术前准确预测前哨淋巴结转移的方法。
  • 研究结果提示,在乳腺癌患者前哨淋巴结评估中,LCEUS加做ICEUS似乎不必要。

研究设计与样本

  • 本研究为术前招募69例乳腺癌患者的研究,所有患者均先行LCEUS后行ICEUS,分析每例患者一枚前哨淋巴结的增强模式。
  • 目标前哨淋巴结以钢丝标记并在术中切除,影像诊断与组织病理结果进行比较。
  • 比较LCEUS、ICEUS及LCEUS与ICEUS联合三种方法的诊断效能。

关键影像表现/征象

  • 原文未报告具体的影像征象描述,仅分析每例患者一枚前哨淋巴结的增强模式。

诊断标准与关键数值

  • LCEUS诊断前哨淋巴结转移的敏感度为86.2%、特异度为95.0%、准确率为91.3%。
  • ICEUS诊断前哨淋巴结转移的敏感度为82.6%、特异度为92.5%、准确率为88.4%。
  • LCEUS与ICEUS联合诊断前哨淋巴结转移的敏感度为93.1%、特异度为87.5%、准确率为89.9%。
  • LCEUS的ROC曲线下面积为0.906,LCEUS、ICEUS及两者联合间无显著差异(p=0.752)。

临床应用与阅片要点

  • 原文未据此给出具体的阅片或报告推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to compare diagnostic efficiency for axillary sentinel lymph node (SLN) metastasis between lymphatic contrast-enhanced ultrasound (LCEUS) and intravenous contrast-enhanced ultrasound (ICEUS) in patients with breast cancer. We also examined whether adding ICEUS to LCEUS could improve the diagnostic accuracy of LCEUS.

METHODS: Sixty-nine patients with breast cancer were recruited preoperatively. All patients underwent LCEUS followed by ICEUS, and the enhancement pattern of one SLN was analysed for each patient. The targeted SLN was marked with wire and excised during surgery. The imaging diagnosis was compared with the histopathological result. Diagnostic efficiency was compared among LCEUS, ICEUS, and the combination of LCEUS and ICEUS.

RESULTS: The sensitivity values for LCEUS, ICEUS, and the combination of LCEUS and ICEUS were 86.2%, 82.6% and 93.1%, respectively. Specificity values for the three methods were 95.0%, 92.5% and 87.5%, respectively. Accuracy values for the three methods were 91.3%, 88.4% and 89.9%, respectively. The area under the receiver operating characteristic (ROC) curve for LCEUS was 0.906, and there was no significant difference among LCEUS, ICEUS, and the combination of LCEUS and ICEUS (p = 0.752).

CONCLUSIONS: LCEUS may represent an accurate method for predicting SLN metastasis preoperatively. Our findings suggest that adding ICEUS to LCEUS for SLN evaluation in patients with breast cancer is unnecessary.

ADVANCES IN KNOWLEDGE: This is the first study in which both LCEUS and ICEUS were performed for the same lymph node and the first to compare the diagnostic efficiency of LCEUS, ICEUS, and the combination of LCEUS + ICEUS.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhuang, Ming, Liu, et al. Comparison of lymphatic contrast-enhanced ultrasound and intravenous contrast-enhanced ultrasound in the preoperative diagnosis of axillary sentinel lymph node metastasis in patients with breast cancer. Br J Radiol. 2021. PMID: 34797694. doi:10.1259/bjr.20210897

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。