前脉络膜动脉动脉瘤弹簧圈栓塞术中运动诱发电位监测的可行性
本研究回顾性分析2014年1月至2018年12月在本机构接受未破裂前脉络膜动脉动脉瘤弹簧圈栓塞的连续患者,比较有无术中运动诱发电位(MEP)监测的临床与血管造影数据。11例接受MEP监测的患者中3例出现MEP波幅降低或消失,但此时血管造影均显示前脉络膜动脉充盈无变化;另1例前脉络膜动脉充盈消失但MEP无变化,可能源于与外侧后脉络膜动脉吻合后的逆行充盈。作者认为术中MEP监测可能可行,但血管造影所示前脉络膜动脉血流并不总是反映MEP状态。
要点
- 前脉络膜动脉动脉瘤栓塞术中,血管造影显示动脉充盈良好时MEP仍可能降低或消失。
- 血管造影显示前脉络膜动脉充盈消失时MEP也可无变化,可能因吻合支逆行充盈。
- 有MEP监测组的弹簧圈栓塞体积比显著优于无监测组。
核心结论
- 前脉络膜动脉动脉瘤血管内弹簧圈栓塞术中行MEP监测可能可行。
- 血管造影检测的前脉络膜动脉血流并不总是反映MEP状态。
研究设计与样本
- 回顾性分析2014年1月至2018年12月在本机构接受弹簧圈栓塞的未破裂前脉络膜动脉瘤连续患者的临床与血管造影数据。
- 共治疗23个未破裂前脉络膜动脉瘤,其中11例接受术中MEP监测。
- 比较有无MEP监测两组的临床与血管造影资料。
关键影像表现/征象
- 11例MEP监测患者中3例出现术中MEP波幅降低或消失,但此3例血管造影均显示前脉络膜动脉充盈无变化。
- 1例MEP监测患者出现前脉络膜动脉充盈消失,但MEP无变化,可能因前脉络膜动脉经与外侧后脉络膜动脉的吻合支逆行充盈所致。
诊断标准与关键数值
- MEP监测组与非监测组比较,弹簧圈栓塞体积比在MEP组显著更优。
临床应用与阅片要点
- 血管造影所示前脉络膜动脉血流并不总是反映MEP状态,阅片与报告中需结合MEP监测结果综合判断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Intraoperative motor-evoked potential (MEP) monitoring is widely used in the neck clipping of cerebral aneurysms. Little is known regarding the usefulness of intraoperative MEP monitoring in endovascular aneurysm surgery. The purpose of this study was to validate the feasibility of intraoperative MEP monitoring during the coil embolization of anterior choroidal artery (AChA) aneurysms.
METHODS: Clinical and angiographic data of consecutive patients who underwent coil embolization for unruptured AChA aneurysms with or without intraoperative MEP monitoring between January 2014 and December 2018 at our institute were abstracted and analyzed retrospectively.
RESULTS: Twenty-three unruptured AChA aneurysms were treated. Eleven patients received MEP monitoring, and three of them experienced intraoperative reduction or disappearance of the MEP wave. Even during MEP changes, AChA filling showed no change in any of the three cases. Although one case with MEP monitoring encountered the disappearance of AChA filling, there was no change in MEP. This might be due to retrograde filling of the AChA from the anastomosis with the lateral posterior choroidal artery. AChA blood flow detected by angiography did not always reflect MEP status. When comparing the presence or absence of MEP monitoring, the volume embolization ratio of coiled aneurysms was significantly better in the MEP group.
CONCLUSION: Intraoperative MEP monitoring during endovascular coiling for AChA aneurysms may be feasible. AChA blood flow detected by angiography does not always reflect MEP status.
引用
- Ito, Sato, Niizuma, et al. Intraoperative motor-evoked potential monitoring during coil embolization for anterior choroidal artery aneurysms. Neuroradiology. 2021. PMID: 34791541. doi:10.1007/s00234-021-02847-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。