三维磁共振弹性成像在胆道梗阻患者中的临床应用
本研究回顾性分析201例无肝病史患者,按胆红素水平分为无黄疸、轻度梗阻性黄疸和重度梗阻性黄疸三组,并与75例经组织学证实肝纤维化的慢性乙型/丙型肝炎患者比较。三维磁共振弹性成像模型在评估梗阻性黄疸严重程度及鉴别梗阻性黄疸与肝纤维化方面显著优于肝脏剪切硬度,但在预测胆道引流结局方面两者效能相当。
要点
- 三维磁共振弹性成像模型评估梗阻性黄疸严重程度的准确率显著高于肝脏剪切硬度(0.801 vs 0.672,p < 0.001)。
- 三维磁共振弹性成像模型鉴别轻度梗阻性黄疸与F1-F2肝纤维化的C统计量显著高于肝脏剪切硬度(0.765 vs 0.641,p = 0.005)。
- 三维磁共振弹性成像模型与肝脏剪切硬度预测胆道引流结局的效能相当(C统计量0.852 vs 0.847,p = 0.48)。
核心结论
- 三维磁共振弹性成像可用于评估梗阻性黄疸严重程度、预测胆道引流结局以及鉴别梗阻性黄疸与肝纤维化。
研究设计与样本
- 回顾性研究,纳入201例无肝病史患者,按胆红素水平分组:无黄疸(≤2 mg/dL,n=75)、轻度梗阻性黄疸(>2 mg/dL且≤4 mg/dL,n=56)、重度梗阻性黄疸(>4 mg/dL,n=70);另纳入75例经组织学证实肝纤维化的慢性乙型/丙型肝炎患者作为对照;所有患者均接受60 Hz自旋回波-回波平面成像磁共振弹性成像检查,并采用三维波后处理。
诊断标准与关键数值
- 三维磁共振弹性成像模型纳入肝脏剪切硬度、损耗模量和阻尼比;评估梗阻性黄疸严重程度的准确率为0.801(肝脏剪切硬度为0.672,p < 0.001);预测胆道引流结局的C统计量为0.852(肝脏剪切硬度为0.847,p = 0.48);鉴别轻度梗阻性黄疸与F1-F2肝纤维化的C统计量为0.765(肝脏剪切硬度为0.641,p = 0.005);鉴别重度梗阻性黄疸与F3-F4肝纤维化的C统计量为0.750(肝脏剪切硬度为0.635,p = 0.031)。
临床应用与阅片要点
- 三维磁共振弹性成像的多参数模型在评估梗阻性黄疸严重程度及鉴别梗阻性黄疸与肝纤维化方面可能优于常规肝脏剪切硬度测量,但在预测胆道引流结局方面与肝脏剪切硬度效能相当。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Three-dimensional magnetic resonance elastography (3D-MRE) allows for multiparametric modeling of both elastic and viscous tissue characteristics. Our aim was to compare 3D-MRE with conventional liver shear stiffness assessment in gauging obstructive jaundice (OJ), predicting the adequacy of biliary decompression after drainage, and discriminating OJ from liver fibrosis.
METHODS: Patients with no histories of liver disease (n = 201) were studied in retrospect, grouped by bilirubin levels as no jaundice (NJ ≤ 2 mg/dL; n = 75), mild OJ (>2 mg/dL and ≤ 4 mg/dL; n = 56), and severe OJ (> 4 mg/dL; n = 70). For comparison, another 75 patients with chronic hepatitis B and C infections and histologically proven liver fibrosis were similarly analyzed. Each patient underwent spin-echo echo-planar-imaging MRE at 60 Hz with 3D wave postprocessing. Logistic regression and ordinary regression models were used to compare the 3D-MRE model with liver shear stiffness.
RESULTS: Liver shear stiffness, loss modulus, and damping ratio were incorporated into a 3D-MRE model, which significantly outperformed shear stiffness in predicting OJ severity (accuracy: 0.801 vs 0.672; p < 0.001). Both the 3D-MRE model and liver shear stiffness performed equally well in predicting the outcome of biliary drainage procedure (C-statistics: 0.852 vs 0.847; p = 0.48). The 3D-MRE model also demonstrated significantly better C-statistics than that of liver shear stiffness in discriminating mild OJ from F1-F2 liver fibrosis (0.765 vs 0.641; p = 0.005) and severe OJ from F3-F4 liver fibrosis (0.750 vs 0.635; p = 0.031).
CONCLUSIONS: 3D-MRE is an innovative imaging method for gauging OJ severity, predicting the outcome of biliary drainage procedure, and discriminating OJ from liver fibrosis.
KEY POINTS: • 3D-MR elastography achieved promising results for predicting the severity of obstructive jaundice. • Advanced parameters of 3D-MR elastography demonstrated significantly better performance than that of shear stiffness of 2D-MR elastography in discriminating obstructive jaundice from liver fibrosis caused by chronic hepatitis B/C. • Both 3D-MR elastography and 2D-MR elastography were equivalent in predicting the outcome of biliary drainage procedure.
引用
- Ma, Wang, Gao, et al. Clinical utility of 3D magnetic resonance elastography in patients with biliary obstruction. Eur Radiol. 2021. PMID: 34791513. doi:10.1007/s00330-021-08295-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。