文献速递腹部MR

自动全肝MRI分割评估慢性肝病脂肪变性和铁定量

Automated Whole-Liver MRI Segmentation to Assess Steatosis and Iron Quantification in Chronic Liver Disease.
PubMed 文献 · Radiology · 2021-11-16

这项前瞻性多中心横断面研究纳入165例慢性肝病患者,以肝活检为参考标准,比较自动全肝分割与手动ROI在PDFF和R2*测量中的表现;两种方法一致性极佳(ICC均为0.98),对脂肪变和铁过载的诊断效能相似,自动分割误差范围更小。

要点

  • 自动全肝分割与手动ROI的PDFF和R2*测量一致性极佳,ICC均为0.98。
  • 自动全肝分割对脂肪变和铁过载的AUC与手动ROI相似,无显著差异。
  • 自动全肝分割的PDFF和R2*估计值略高,但误差范围小于手动ROI。

核心结论

  • 自动全肝分割得出的PDFF和R2*测量对慢性肝病脂肪变和铁分级准确,且与数字病理相关;自动估计值更高,误差范围小于手动ROI。

研究设计与样本

  • 前瞻性、横断面、多中心研究,2017年1月至2021年1月招募165例接受肝活检和化学位移编码3.0-T MRI的慢性肝病患者,以肝活检(组织学分级和数字病理)为参考标准。

诊断标准与关键数值

  • 自动全肝分割与手动ROI的PDFF和R2*均值一致性ICC均为0.98。
  • PDFF中位偏差0.5%(四分位距-0.4%至1.2%),R2*中位偏差2.7 sec-1(四分位距0.2-5.3 sec-1),两者P均<.001。
  • 脂肪变诊断AUC:手动ROI 0.96 vs 自动全肝分割0.97(P=.53)。
  • 铁过载诊断AUC:手动ROI 0.85 vs 自动全肝分割0.83(P=.09)。
  • 脂肪比率与PDFF相关性:手动ROI r=0.89,自动全肝分割r=0.90(P<.001);铁比率与R2*相关性:手动ROI r=0.65,自动全肝分割r=0.64(P<.001)。

临床应用与阅片要点

  • 自动全肝分割可用于慢性肝病MRI PDFF和R2*测量,与手动ROI诊断效能相似。
  • 自动全肝分割的PDFF和R2*估计值较手动ROI略高,但误差范围更小。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Standardized manual region of interest (ROI) sampling strategies for hepatic MRI steatosis and iron quantification are time consuming, with variable results. Purpose To evaluate the performance of automatic MRI whole-liver segmentation (WLS) for proton density fat fraction (PDFF) and iron estimation (transverse relaxometry [R2*]) versus manual ROI, with liver biopsy as the reference standard. Materials and Methods This prospective, cross-sectional, multicenter study recruited participants with chronic liver disease who underwent liver biopsy and chemical shift-encoded 3.0-T MRI between January 2017 and January 2021. Biopsy evaluation included histologic grading and digital pathology. MRI liver sampling strategies included manual ROI (two observers) and automatic whole-liver (deep learning algorithm) segmentation for PDFF- and R2*-derived measurements. Agreements between segmentation methods were measured using intraclass correlation coefficients (ICCs), and biases were evaluated using Bland-Altman analyses. Linear regression analyses were performed to determine the correlation between measurements and digital pathology. Results A total of 165 participants were included (mean age ± standard deviation, 55 years ± 12; 96 women; 101 of 165 participants [61%] with nonalcoholic fatty liver disease). Agreements between mean measurements were excellent, with ICCs of 0.98 for both PDFF and R2*. The median bias was 0.5% (interquartile range, -0.4% to 1.2%) for PDFF and 2.7 sec-1 (interquartile range, 0.2-5.3 sec-1) for R2* (P < .001 for both). Margins of error were lower for WLS than ROI-derived parameters (-0.03% for PDFF and -0.3 sec-1 for R2*). ROI and WLS showed similar performance for steatosis (ROI AUC, 0.96; WLS AUC, 0.97; P = .53) and iron overload (ROI AUC, 0.85; WLS AUC, 0.83; P = .09). Correlations with digital pathology were high (P < .001) between the fat ratio and PDFF (ROI r = 0.89; WLS r = 0.90) and moderate (P < .001) between the iron ratio and R2* (ROI r = 0.65; WLS r = 0.64). Conclusion Proton density fat fraction and transverse relaxometry measurements derived from MRI automatic whole-liver segmentation (WLS) were accurate for steatosis and iron grading in chronic liver disease and correlated with digital pathology. Automated WLS estimations were higher, with a lower margin of error than manual region of interest estimations. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Moura Cunha and Fowler in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Martí-Aguado, Jiménez-Pastor, Alberich-Bayarri, et al. Automated Whole-Liver MRI Segmentation to Assess Steatosis and Iron Quantification in Chronic Liver Disease. Radiology. 2021. PMID: 34783592. doi:10.1148/radiol.2021211027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。