深度学习图像重建算法用于降低碘剂量双能CT血管成像的初步结果
研究纳入22例行全身双能CT血管成像(对比剂碘剂量200 mg碘/kg)患者,在40 keV下比较混合迭代重建(hybrid-IR)与深度学习图像重建中、高等级(DLIR-M、DLIR-H)的图像质量。结果示DLIR-H背景噪声显著低于hybrid-IR和DLIR-M,轴位、MPR及VR图像质量显著更优,血管CT衰减值及动脉显示基本相当。
要点
- 40 keV下DLIR-H较混合迭代重建显著降低背景噪声并提升轴位、MPR及VR图像质量。
- DLIR-H与混合迭代重建的血管CT衰减值及绝大多数动脉显示无显著差异。
- 低碘剂量(200 mg碘/kg)全身双能CTA在40 keV下采用DLIR-H可维持动脉显示。
核心结论
- 与混合迭代重建相比,DLIR在40 keV双能CTA中显著降低背景噪声并改善图像质量,同时维持几乎所有动脉的显示。
研究设计与样本
- 前瞻性初步研究,纳入22例患者行全身双能CT血管成像,碘剂量200 mg碘/kg,层厚1.25 mm、重叠50%,于40 keV下分别以40%自适应统计迭代重建联合Veo(混合迭代重建组)、DLIR中等级(DLIR-M组)和高等级(DLIR-H组)重建。
关键影像表现/征象
- 三组胸主动脉、腹主动脉及髂动脉的血管CT衰减值基本相当(p=0.013–0.97)。
- DLIR-H组背景噪声显著低于混合迭代重建组和DLIR-M组(p<0.001)。
- 轴位及MPR图像上动脉显示、VR图像上几乎所有动脉的显示在三组间相当(p=0.14–1)。
- DLIR-H组轴位、MPR及VR图像质量显著优于其他两组(p<0.001–0.015)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the computed tomography (CT) attenuation values, background noise, arterial depiction, and image quality in whole-body dual-energy CT angiography (DECTA) at 40 keV with a reduced iodine dose using deep-learning image reconstruction (DLIR) and compare them with hybrid iterative reconstruction (IR).
MATERIAL AND METHODS: Whole-body DECTA with a reduced iodine dose (200 mg iodine/kg) was performed in 22 patients, and DECTA data at 1.25-mm section thickness with 50% overlap were reconstructed at 40 keV using 40% adaptive statistical iterative reconstruction with Veo (hybrid-IR group), and DLIR at medium and high levels (DLIR-M and DLIR-H groups). The CT attenuation values of the thoracic and abdominal aortas and iliac artery and background noise were measured. Arterial depiction and image quality on axial, multiplanar reformatted (MPR), and volume-rendered (VR) images were assessed by two readers. Quantitative and qualitative parameters were compared between the hybrid-IR, DLIR-M, and DLIR-H groups.
RESULTS: The vascular CT attenuation values were almost comparable between the three groups (p=0.013-0.97), but the background noise was significantly lower in the DLIR-H group than in the hybrid-IR and DLIR-M groups (p<0.001). The arterial depictions on axial and MPR images and in almost all arteries on VR images were comparable (p=0.14-1). The image quality of axial, MPR, and VR images was significantly better in the DLIR-H group (p<0.001-0.015).
CONCLUSION: DLIR significantly reduced background noise and improved image quality in DECTA at 40 keV compared with hybrid-IR, while maintaining the arterial depiction in almost all arteries.
引用
- Noda, Nakamura, Kawamura, et al. Deep-learning image-reconstruction algorithm for dual-energy CT angiography with reduced iodine dose: preliminary results. Clin Radiol. 2021. PMID: 34782114. doi:10.1016/j.crad.2021.10.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。