双能CT灌注评估非小细胞肺癌侵袭性肿瘤前沿
前瞻性研究于2016-2017年纳入可手术非小细胞肺癌患者,行双期双能CT灌注,计算整体肿瘤及自动分割的三层外周2mm厚同心亚体积的首过和延迟碘浓度及归一化碘摄取,并与肿瘤标本膜性碳酸酐酶IX表达对照。33例mCA IX阳性与16例阴性肿瘤中,延迟期整体归一化碘摄取高于首过(0.35±0.17 vs 0.13±0.15,P<.001);肿瘤边缘单层在mCA IX阳性者首过碘浓度(中位0.53 mg/mL vs 0.21 mg/mL,P=.03)和归一化碘摄取(0.04 vs 0.02,P=.03)更高。
要点
- 双期双能CT可显示缺氧肿瘤边缘与肺实质之间灌注更高。
- 肿瘤边缘单层首过碘浓度在mCA IX阳性肿瘤更高(中位0.53 mg/mL vs 0.21 mg/mL)。
- 该层内23/33(70%)mCA IX阳性肿瘤呈新生血管功能型,其中位mCA IX评分高于非功能型(20 vs 2)。
核心结论
- 双期双能CT检查可显示缺氧肿瘤边缘与肺实质之间灌注更高。
研究设计与样本
- 前瞻性研究,2016-2017年,连续纳入可手术非小细胞肺癌患者,行两期双能CT协议,以肿瘤标本膜性碳酸酐酶IX表达为参考,共33例mCA IX阳性与16例mCA IX阴性肿瘤。
关键影像表现/征象
- 整个肿瘤延迟期平均归一化碘摄取高于首过(0.35±0.17 vs 0.13±0.15,P<.001)。
- 位于肿瘤边缘的单层在mCA IX阳性较阴性肿瘤首过碘浓度更高(中位0.53 mg/mL vs 0.21 mg/mL,P=.03)。
- 同层首过归一化碘摄取在mCA IX阳性较阴性肿瘤更高(0.04 vs 0.02,P=.03)。
- 该层内23/33(70%)mCA IX阳性肿瘤呈新生血管功能型,其中位mCA IX评分高于非功能型肿瘤(20 vs 2,P=.03)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Active endothelial cell proliferation occurs at the tumor edge, known as the invading-tumor front. This study focused on perfusion analysis of non-small cell lung cancers. Purpose To analyze dual-phase, dual-energy CT perfusion according to the degree of tumor hypoxia. Materials and Methods This prospective study was performed 2016-2017. A two-phase dual-energy CT protocol was obtained for consecutive participants with operable non-small cell lung cancer. The first pass and delayed iodine concentration within the tumor and normalized iodine uptake, corresponding to the iodine concentration within the tumor normalized to iodine concentration within the aorta, were calculated for the entire tumor and within three peripheral layers automatically segmented (ie, 2-mm-thick concentric subvolumes). The expression of the membranous carbonic anhydrase (mCA) IX, a marker of tumor hypoxia, was assessed in tumor specimens. Comparative analyses according to the histologic subtypes, type of resected tumors, and mCA IX expression were performed. Results There were 33 mCA IX-positive tumors and 16 mCA IX-negative tumors. In the entire tumor, the mean normalized iodine uptake was higher on delayed than on first-pass acquisitions (0.35 ± 0.17 vs 0.13 ± 0.15, respectively; P < .001). A single layer, located at the edge of the tumor, showed higher values of the iodine concentration (median, 0.53 mg/mL vs 0.21 mg/mL, respectively; P = .03) and normalized iodine uptake (0.04 vs 0.02, respectively; P = .03) at first pass in mCA IX-positive versus mCA IX-negative tumors. Within this layer, a functional profile of neovascularization was found in 23 of 33 (70%) of mCA IX-positive tumors, and the median mCA IX score of these tumors was higher than in tumors with a nonfunctional profile of neovascularization (median mCA IX score, 20 vs 2, respectively; P = .03). Conclusion A two-phase dual-energy CT examination depicted higher perfusion between the tumor edge and lung parenchyma in hypoxic tumors. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Murphy and Ryan in this issue.
引用
- Dewaguet, Copin, Duhamel, et al. Dual-Energy CT Perfusion of Invasive Tumor Front in Non-Small Cell Lung Cancers. Radiology. 2021. PMID: 34783594. doi:10.1148/radiol.2021210600
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。