锥形束CT血管造影显示视网膜中央动脉
这项回顾性研究纳入2019年10月至2020年10月间接受导管DSA且CBCT血管造影视野包含眼眶的患者,对后眼球为中心的小视野数据集以最高0.2 mm分辨率后处理,评估视网膜中央动脉的起源、走行、穿入视神经鞘点及乳头部分叉等。21例患者24个眼眶中视网膜中央动脉均被识别,神经内段平均长度10.6 mm(范围7-18 mm),24个眼眶中6个识别出视网膜中央静脉。
要点
- CBCT血管造影可在诊断性脑血管造影中一致显示视网膜中央动脉。
- 神经内段平均长度10.6 mm(范围7-18 mm)。
- 24个眼眶中仅6个识别出视网膜中央静脉。
核心结论
- 在诊断性血管造影期间行锥形束CT可一致显示活体视网膜中央动脉,在多种诊断和治疗应用方面显示出良好潜力。
研究设计与样本
- 回顾性研究,纳入2019年10月至2020年10月间接受导管DSA且CBCT血管造影视野包含眼眶的患者21例(24个眼眶,平均年龄55岁±15,14名女性),CBCT血管造影数据集以后眼球为中心的小视野容积后处理至最高分辨率0.2 mm,行描述性统计分析。
关键影像表现/征象
- 视网膜中央动脉在所有眼眶中均被识别,其起源、走行、穿入视神经鞘点及乳头内终止在所有眼眶中均可见。
- 神经内段平均长度10.6 mm(范围7-18 mm)。
- 视网膜中央静脉在24个眼眶中的6个被识别。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background There are multiple tools available to visualize the retinal and choroidal vasculature of the posterior globe. However, there are currently no reliable in vivo imaging techniques that can visualize the entire retrobulbar course of the retinal and ciliary vessels. Purpose To identify and characterize the central retinal artery (CRA) using cone-beam CT (CBCT) images obtained as part of diagnostic cerebral angiography. Materials and Methods In this retrospective study, patients with catheter DSA performed between October 2019 and October 2020 were included if CBCT angiography included the orbit in the field of view. The CBCT angiography data sets were postprocessed with a small field-of-view volume centered in the posterior globe to a maximum resolution of 0.2 mm. The following were evaluated: CRA origin, CRA course, CRA point of penetration into the optic nerve sheath, bifurcation of the CRA at the papilla, visualization of anatomic variants, and visualization of the central retinal vein. Descriptive statistical analysis was performed. Results Twenty-one patients with 24 visualized orbits were included in the analysis (mean age, 55 years ± 15; 14 women). Indications for angiography were as follows: diagnostic angiography (n = 8), aneurysm treatment (n = 6), or other (n = 7). The CRA was identified in all orbits; the origin, course, point of penetration of the CRA into the optic nerve sheath, and termination in the papilla were visualized in all orbits. The average length of the intraneural segment was 10.6 mm (range, 7-18 mm). The central retinal vein was identified in six of 24 orbits. Conclusion Cone-beam CT, performed during diagnostic angiography, consistently demonstrated the in vivo central retinal artery, demonstrating excellent potential for multiple diagnostic and therapeutic applications. © RSNA, 2021 Online supplemental material is available for this article.
引用
- Raz, Shapiro, Shepherd, et al. Central Retinal Artery Visualization with Cone-Beam CT Angiography. Radiology. 2021. PMID: 34783593. doi:10.1148/radiol.2021210520