术后1小时搏动指数独立预测机械取栓成功再通后的无效再通
单中心前瞻性队列纳入122例前循环大血管闭塞成功再通(mTICI≥2b)患者,术后1小时症状侧搏动指数(PI)在无效再通组显著升高(1.23 vs 0.81),ROC分析显示PI>0.99时敏感度91.7%、特异度89.2%,多因素分析中1小时PI与入院NIHSS为独立预测因子。
要点
- 取栓成功再通后1小时床旁经颅多普勒测症状侧PI>0.99提示无效再通高风险。
- 无效再通组PI(1.23)明显高于有效再通组(0.81),PI单独判别AUC高。
- 术前超声ONSD在无效再通组更高(5.2 vs 4.7 mm,AUC 0.785),可辅助风险分层。
核心结论
- 术后1小时症状侧搏动指数与无效再通独立相关,判别效能高。
- 术前视神经鞘直径可能提供补充性风险分层信息。
- 结论尚需多中心外部验证。
研究设计与样本
- 单中心前瞻性观察性研究,2025年10月至2026年4月连续纳入122例成功再通(mTICI≥2b;2b病例均为eTICI 2b67)的前循环大血管闭塞患者。
- 术前用超声测量视神经鞘直径(ONSD)。
- 术后由未参与手术且对取栓技术和血管造影再通结果设盲的研究者行经颅彩色多普勒测量。
- 无效再通定义为90天mRS 3-6。
- 采用ROC分析及DeLong比较评估判别效能,多因素logistic回归(5000次bootstrap重采样)筛选独立预测因子。
关键影像表现/征象
- 无效再通组术后1小时症状侧搏动指数显著升高(1.23 vs 0.81,p<0.001)。
- 无效再通组术前视神经鞘直径更高(5.2 vs 4.7 mm,p<0.001,AUC 0.785)。
诊断标准与关键数值
- 1小时症状侧PI判别无效再通:阈值>0.99时敏感度91.7%(95%CI 80.4-96.7%),特异度89.2%(95%CI 80.1-94.4%)。
- 术前ONSD判别无效再通的AUC为0.785。
- PI联合ONSD等指标的组合模型AUC达0.934,较PI单独无显著增量获益(p=0.062)。
- 多因素分析:1小时PI的OR 2.929(p<0.001),入院NIHSS的OR 1.457(p=0.009)。
- 局部麻醉亚组预测效能保持,AUC 0.895。
临床应用与阅片要点
- 取栓成功再通后可行床旁经颅多普勒测量症状侧PI,辅助早期识别无效再通高风险患者。
- 术前超声ONSD测量简便,可作为补充性风险分层指标。
- PI阈值>0.99判别效能高,但需注意本研究为单中心,阈值外推需谨慎。
局限性
- 单中心研究,样本量有限(122例),结论需多中心外部验证。
- 无效再通定义为90天mRS 3-6,属功能性结局而非影像学再通评估。
英文原文(摘要)· 点击展开
Neuroradiology . 2026 Oct 30. doi: 10.1007/s00234-026-04245-9. Online ahead of print. ABSTRACT BACKGROUND: Futile recanalization (FR) - poor functional outcome despite successful mechanical thrombectomy - affects approximately 40% of patients with anterior circulation large vessel occlusion. Reliable bedside predictors of FR at the time of recanalization remain lacking. METHODS: This single-center prospective observational study enrolled 122 consecutive patients with successful thrombectomy (mTICI ≥2b; all mTICI 2b cases corresponded to eTICI 2b67) between 1 October 2025 and 12 April 2026. Pre-procedural optic nerve sheath diameter (ONSD) was measured by ultrasound, and post-procedural transcranial color-coded Doppler measurements were obtained by an investigator who was not involved in the endovascular procedure and was blinded to the thrombectomy technique and angiographic reperfusion findings. FR was defined as 90-day mRS 3-6. Discriminative performance was assessed by ROC analysis with DeLong comparison; independent predictors by multivariable logistic regression with bootstrap validation (5000 resamples). RESULTS: FR occurred in 48 patients (39.3%). The 1-hour symptomatic-hemisphere pulsatility index (PI) was markedly elevated in FR patients (1.23 vs. 0.81; p 0.99, sensitivity was 91.7% (95% CI: 80.4-96.7%) and specificity 89.2% (95% CI: 80.1-94.4%).Preoperative ONSD was also higher in FR patients (5.2 vs. 4.7 mm; p < 0.001; AUC 0.785). The combined model reached AUC 0.934, without significant incremental gain over PI alone (p = 0.062). On multivariable analysis, 1-hour PI (OR 2.929; p < 0.001) and admission NIHSS (OR 1.457; p = 0.009) were independent predictors. Predictive accuracy was preserved in the local anesthesia subgroup (AUC 0.895). CONCLUSIONS: The 1-hour symptomatic PI was independently associated with futile recanalization and showed high discriminatory performance after thrombectomy. Preoperative ONSD may provide complementary risk stratification. Multicenter external validation is warranted. PMID: 42961455 | DOI: 10.1007/s00234-026-04245-9
引用
- Neuroradiology(PubMed 期刊源):One-hour pulsatility index as an independent predictor of futile recanalization after successful mechanical thrombectomy: A prospective observational study
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。