MRI检测全髋关节置换术后外侧入路症状性患者髋外展肌腱撕裂
回顾性纳入36例全髋关节置换术后因疑似外展肌腱撕裂行翻修术且有术前MRI的患者,以术中所见为参考标准。MRI检测臀中肌和臀小肌部分或全层撕裂的敏感度0.86-1.00、特异度0.90-1.00、准确度0.89-1.00。肌腱缺损和转子周围积液与部分或全层撕裂显著相关。
要点
- MRI对全髋置换术后症状性患者外展肌腱撕裂诊断准确度高
- 肌腱缺损和转子周围积液与部分或全层撕裂显著相关
- Goutallier分级越高,肌腱撕裂风险越大
关键影像表现/征象
- MRI评估肌腱完整性分为完整、部分层撕裂或全层撕裂。
- 肌腱缺损与臀中肌部分或全层撕裂相关(OR=35.5,p=0.007),与臀小肌部分或全层撕裂相关(OR=30.0,p<0.001)。
- 转子周围积液与臀中肌部分或全层撕裂相关(OR=64.2,p=0.01),与臀小肌部分或全层撕裂相关(OR=74.9,p=0.01)。
- 较高Goutallier分级与臀中肌部分或全层撕裂相关(OR=2.34,p=0.03),与臀小肌部分或全层撕裂相关(OR=4.75,p=0.02)。
诊断标准与关键数值
- Reader 1检测外展肌腱撕裂的敏感度0.86-1.00、特异度0.93-1.00、准确度0.92-0.97。
- Reader 2检测外展肌腱撕裂的敏感度0.86-1.00、特异度0.90-1.00、准确度0.89-1.00。
- 参考标准为术中所见部分或全层撕裂。
临床应用与阅片要点
- 对全髋关节置换术后症状性患者,MRI可无创评估外展肌腱完整性。
- 阅片时应关注肌腱缺损、转子周围积液和Goutallier分级,这些征象与撕裂显著相关。
局限性
- 回顾性研究。
- 样本量较小(36例)。
- 为选定手术队列,结果可能不适用于所有全髋关节置换术后患者。
英文原文(摘要)· 点击展开
Eur Radiol. 2026 Oct 30. doi: 10.1007/s00330-026-12856-2. Online ahead of print. ABSTRACT OBJECTIVES: To evaluate the diagnostic accuracy of MRI for detecting clinically suspected hip abductor tendon tears in symptomatic patients after total hip arthroplasty and to evaluate the association between specific MRI features and surgically confirmed tears. MATERIALS AND METHODS: This retrospective study included 36 patients with total hip arthroplasty who underwent revision surgery for a suspected abductor tendon tear and had preoperative MRI available. Intraoperative findings served as the reference standard for the presence of partial or full-thickness tears of the gluteus medius (Gmed) and gluteus minimus (Gmin) tendons. Two readers evaluated MRI for tendon integrity (intact, partial-thickness, or full-thickness tear). Associations between tendon defects, peritrochanteric fluid, tendon signal abnormalities, and Gmed/Gmin Goutallier grades with surgical findings were analyzed using regression models to calculate odds ratios (ORs). RESULTS: For detection of abductor tendon tears, Reader 1 achieved sensitivities of 0.86-1.00, specificities of 0.93-1.00, and accuracies of 0.92-0.97, while Reader 2 achieved sensitivities of 0.86-1.00, specificities of 0.90-1.00, and accuracies of 0.89-1.00. Imaging findings associated with partial- or full-thickness tears included tendon defects (Gmed: OR = 35.5, p = 0.007; Gmin: OR = 30.0, p < 0.001), peritrochanteric fluid (Gmed: OR = 64.2, p = 0.01; Gmin: OR = 74.9, p = 0.01), and higher Goutallier grade (Gmed: OR = 2.34, p = 0.03; Gmin: OR = 4.75, p = 0.02). CONCLUSION: MRI demonstrated high diagnostic accuracy for detecting surgically confirmed hip abductor tendon tears in this selected symptomatic surgical cohort following total hip arthroplasty. Tendon defects and peritrochanteric fluid were significantly associated with partial- or full-thickness tendon tears. KEY POINTS: Question There is limited data on the diagnostic accuracy of MRI for hip abductor tendon tear detection following total hip arthroplasty. Findings MRI demonstrated high diagnostic accuracy for detecting surgically confirmed abductor tendon tears in symptomatic patients with total hip arthroplasty. Clinical relevance In symptomatic patients with clinical suspicion of an abductor tendon tear undergoing evaluation for revision surgery, MRI can be used to noninvasively assess the integrity of the abductor tendons after total hip arthroplasty. PMID: 42961652 | DOI: 10.1007/s00330-026-12856-2
引用
- European Radiology(PubMed 期刊源):MRI for the detection of hip abductor tendon tears in symptomatic patients with total hip arthroplasty following a lateral surgical approach
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。