文献速递外周血管技术与安全US

急诊床旁超声诊断近端下肢深静脉血栓准确性的系统评价与荟萃分析

Diagnostic accuracy of point-of-care ultrasound for proximal lower-extremity deep vein thrombosis in emergency settings: A systematic review and meta-analysis
RSS 订阅 · PubMed 高证据 · 超声 · 2026-10-30

该系统评价与荟萃分析纳入16项急诊成人疑似DVT研究,评估急诊医师操作超声的诊断准确性。汇总敏感度0.91(95%CI 0.85-0.95),特异度0.95(95%CI 0.91-0.97)。两点法与三点/扩展方案敏感度分别为0.87和0.92。阴性有限检查需结合临床概率和检查充分性解读。

要点

  • 急诊医师床旁超声诊断近端DVT汇总敏感度0.91、特异度0.95。
  • 阴性有限检查不能单独排除DVT,需结合临床概率与检查充分性。
  • 两点与三点方案敏感度有差异,但亚组分析为探索性,不能确立优劣。

关键影像表现/征象

  • 原文未报告具体影像征象,仅以近端下肢深静脉血栓为诊断目标。
  • 诊断准确性按两点方案与三点/扩展方案进行亚组比较,敏感度分别为0.87和0.92。

诊断标准与关键数值

  • 汇总敏感度0.91(95%CI 0.85-0.95),特异度0.95(95%CI 0.91-0.97)。
  • 两点方案敏感度0.87,三点/扩展方案敏感度0.92,均为探索性亚组结果。
  • 主分析每项研究仅纳入一个数据集以避免配对队列重复加权。

临床应用与阅片要点

  • 急诊床旁超声可用于疑似近端DVT的初步评估,但阴性有限检查需结合临床概率和检查充分性。
  • 报告时应注明所用扫描方案(两点或三点/扩展)及检查是否充分。
  • 探索性亚组结果不足以推荐某一方案或操作者组别优于其他。

局限性

  • 研究间存在异质性,降低汇总估计的置信度。
  • 源数据存在不确定性,包括Jahanian 2019重建诊断分析表和Crowhurst暂定输入。
  • 方案与操作者亚组分析为探索性,不能确立优劣。
英文原文(摘要)· 点击展开

Sci Prog. 2026 Oct-Dec;109(4):368504261503871. doi: 10.1177/00368504261503871. Epub 2026 Oct 30. ABSTRACT ObjectiveTo evaluate the diagnostic accuracy of emergency clinician-performed ultrasound for proximal lower-extremity deep vein thrombosis (DVT) and explore variation by scan protocol and operator group.MethodsThis systematic review and meta-analysis included studies of adults with suspected DVT in emergency settings. PubMed, Embase, the Cochrane Library, and Web of Science Core Collection were searched from inception to 8 April 2026, and a targeted literature update was conducted through 20 September 2026 during revision. A bivariate binomial random-effects model jointly estimated sensitivity and specificity. The primary analysis included one dataset per study to avoid duplicate weighting of paired cohorts. Risk of bias and applicability were assessed with QUADAS-2. Protocol and operator subgroup analyses were exploratory. The review was registered in PROSPERO (CRD420261361599).ResultsSixteen studies contributed quantitative data, providing 17 protocol datasets because one paired cohort was evaluated with both two-point and three-point protocols. Selecting the three-point result from that paired cohort for the primary overall model yielded 16 independent study datasets comprising 2,781 patient or limb/examination units. Pooled sensitivity was 0.91 (95% confidence interval [CI] 0.85-0.95), and specificity was 0.95 (95% CI 0.91-0.97). Sensitivity estimates for two-point and three-point/extended protocols were 0.87 and 0.92, respectively. Source-data uncertainties, including a reconstructed diagnostic-analysis table in Jahanian 2019 and a provisional Crowhurst input, were examined in sensitivity analyses. Koylu 2026 was added during the revision-stage targeted literature update.ConclusionsEmergency clinician-performed ultrasound may support proximal DVT assessment within a defined diagnostic pathway. Negative limited examinations require interpretation alongside clinical probability and examination adequacy. Heterogeneity and unresolved source data limit confidence in the pooled estimates. Exploratory subgroup findings do not establish the superiority of any protocol or operator group. PMID: 42961238 | DOI: 10.1177/00368504261503871

来源:PubMed 高证据 · 超声,查看原文。版权归原作者所有。

引用

  1. PubMed 高证据 · 超声:Diagnostic accuracy of point-of-care ultrasound for proximal lower-extremity deep vein thrombosis in emergency settings: A systematic review and meta-analysis

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。