全自动深度学习评估下肢X线片膝关节对线:横断面诊断研究
本研究评估商用AI软件在站立位全长腿X线片上测量膝关节对线及腿长差异的性能,与人工测量对比。回顾性分析295张X线片,AI输出率98.0%,整体准确率89.2%,角度sMAD 0.39-2.19°、长度1.45-5.00 mm,ICC≥0.87,非劣效性成立,平均节省130秒。结论:AI测量可重复、准确且省时。
要点
- AI可自动测量膝关节对线角度和长度,ICC≥0.87,与人工测量高度一致。
- AI整体准确率89.2%,角度偏差≤2.19°,长度偏差≤5.00 mm。
- AI平均比临床医生快130秒,有望提升阅片效率。
核心结论
- AI工具自动测量膝关节对线和长度可获得可重复、准确的结果,并比人工测量节省时间。
研究设计与样本
- 回顾性单中心横断面诊断研究,纳入2015-2020年间295张站立位全长腿X线片(284例患者,平均年龄65岁,97例男性)。
- AI软件在超过15,000张X线片上训练,用于测量多种临床角度和长度;AI与专家独立测量,以人工标注为参考标准。
诊断标准与关键数值
- AI模型在98.0%的全长腿X线片上产生输出,整体准确率为89.2%(AI输出与人工测量比较)。
- AI与观察者均值比较:角度sMAD为0.39-2.19°,长度sMAD为1.45-5.00 mm;所有长度和角度的ICC≥0.87。
- 非劣效性检验:角度等效指数γ为0.54-3.03°,长度γ为-0.70-1.95 mm。
- AI平均比临床医生快130秒。
临床应用与阅片要点
- 日常阅片时可利用AI自动测量全长腿X线片上的膝关节对线角度和长度,提高报告一致性。
- AI测量与人工测量高度一致,但需注意长度测量偏差可达5.00 mm,角度偏差可达2.19°。
局限性
- 回顾性单中心研究,样本量295张X线片,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Accurate assessment of knee alignment and leg length discrepancy is currently measured manually from standing long-leg radiographs (LLR), a process that is both time consuming and poorly reproducible. The aim was to assess the performance of a commercial available AI software by comparing its outputs with manually performed measurements.
MATERIALS AND METHODS: The AI was trained on over 15,000 radiographs to measure various clinical angles and lengths from LLRs. We performed a retrospective single-center analysis on 295 LLRs obtained between 2015 and 2020 from male and female patients over 18 years. AI and expert measurements were performed independently. Kellgren-Lawrence score and reading time were assessed. All measurements were compared and non-inferiority, mean-absolute-deviation (sMAD), and intra-class-correlation (ICC) were calculated.
RESULTS: A total of 295 LLRs from 284 patients (mean age, 65 years (18; 90); 97 (34.2%) men) were analyzed. The AI model produces outputs on 98.0% of the LLRs. Manually annotations were considered as 100% accurate. For each measurement, its divergence was calculated, resulting in an overall accuracy of 89.2% when comparing the AI outputs to the manually measured. AI vs. mean observer revealed an sMAD between 0.39 and 2.19° for angles and 1.45-5.00 mm for lengths. AI showed good reliability in all lengths and angles (ICC ≥ 0.87). Non-inferiority comparing AI to the mean observer revealed an equivalence-index (γ) between 0.54 and 3.03° for angles and - 0.70-1.95 mm for lengths. On average, AI was 130 s faster than clinicians.
CONCLUSION: Automated measurements of knee alignment and length measurements produced with an AI tool result in reproducible, accurate measures with a time savings compared to manually acquired measurements.
引用
- Simon, Schwarz, Aichmair, et al. Fully automated deep learning for knee alignment assessment in lower extremity radiographs: a cross-sectional diagnostic study. Skeletal Radiol. 2021. PMID: 34773485. doi:10.1007/s00256-021-03948-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。