基于多平面重建测量纯磨玻璃结节圆度预测肺腺癌浸润性的回顾性分析
本研究回顾性分析168个经手术病理证实的纯磨玻璃结节(pGGN),使用Photoshop在薄层CT轴位、冠状位和矢状位图像上测量圆度。结果显示浸润组圆度值均显著低于前浸润组(均p<0.001),冠状位和矢状位圆度的预测价值优于轴位,其中矢状位圆度预测浸润性的AUC最高(0.870)。
要点
- 测量pGGN圆度有助于预测肺腺癌浸润性,矢状位圆度预测价值最佳。
- 浸润组pGGN圆度在各切面均显著低于前浸润组(p<0.001)。
- 冠状位和矢状位圆度预测浸润性优于常规轴位(OR分别为14.858和23.315)。
关键影像表现/征象
- 前浸润组pGGN圆度在轴位、冠状位和矢状位分别为0.8±0.049、0.816±0.05和0.818±0.043;浸润组分别为0.745±0.077、0.684±0.106和0.678±0.106,两组差异均有统计学意义(均p<0.001)。
诊断标准与关键数值
- ROC分析显示矢状位圆度预测pGGN浸润性的AUC为0.870,优于冠状位的0.832。
- 二元logistic回归显示冠状位和矢状位圆度预测浸润性的OR值分别为14.858和23.315(均p<0.001),轴位圆度无统计学意义(p>0.05)。
临床应用与阅片要点
- 阅片时应在薄层CT冠状位和矢状位多平面重建图像上测量pGGN圆度,以辅助判断浸润性。
- 矢状位圆度测量对预测pGGN浸润性价值最高,可作为报告参考指标。
局限性
- 本研究为单中心回顾性分析,结果需前瞻性多中心研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To explore the value of roundness measurement based on thin-section axial, coronal, and sagittal section computed tomography (CT) images for predicting pure ground-glass nodule (pGGN) invasiveness.
MATERIALS AND METHODS: A total of 168 pGGNs in 155 patients (44 male, 111 females; mean age, 55.74 ± 10.57 years), and confirmed by surgery and histopathology, were analysed retrospectively and divided into pre-invasive (n=72) and invasive (n=96) groups. Photoshop (CS6) software was used to measure pGGN roundness based on conventional axial section, as well as coronal and sagittal sections generated by multiplanar reformation, from thin-section (1-mm-thick) CT lung images.
RESULTS: pGGN roundness values, measured in axial, coronal, and sagittal thin-section CT sections from the pre-invasive group were 0.8 ± 0.049, 0.816 ± 0.05, and 0.818 ± 0.043, respectively, while those in the invasive group were 0.745 ± 0.077, 0.684 ± 0.106, and 0.678 ± 0.106; differences between the two groups were significant (all p<0.001). Binary logistic regression analysis showed that roundness values based on coronal and sagittal sections (p<0.001) were better than those from axial sections (p>0.05) in predicting pGGN invasiveness, with odds ratio (OR) values of 14.858 and 23.315, respectively. ROC analysis showed that evaluation of roundness measured in sagittal sections was better at predicting pGGN invasiveness than when coronal sections were used (AUC 0.870 versus 0.832).
CONCLUSION: Roundness is useful for predicting pGGN invasiveness, with measurements from coronal and sagittal sections better than those from conventional axial sections, with sagittal section images having the best predictive value.
引用
- Wang, Ba, Yin, et al. Predicting lung adenocarcinoma invasiveness by measurement of pure ground-glass nodule roundness by using multiplanar reformation: a retrospective analysis. Clin Radiol. 2021. PMID: 34772486. doi:10.1016/j.crad.2021.10.007