文献速递外周血管技术与安全MR

QISS非增强MRA在外周动脉疾病诊断准确性的Meta分析

A meta-analysis of the diagnostic performance of quiescent-interval-single-shot magnetic resonance angiography in peripheral arterial disease.
PubMed 文献 · Eur Radiol · 2021-11-12

结果显示,基于血管节段的合并敏感度为0.88(95%CI: 0.85-0.91),特异度为0.94(95%CI: 0.92-0.96),AUC为0.96(95%CI: 0.94-0.98),提示QISS具有高诊断准确性。

要点

  • QISS诊断外周动脉狭窄/闭塞的合并敏感度88%、特异度94%。
  • QISS可作为肾功能不全、孕妇及对比剂过敏患者的首选检查。
  • 研究间存在中度至显著异质性(I2=69%),需结合临床解读。
英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate by meta-analysis the diagnostic accuracy of non-contrast quiescent-interval-single-shot (QISS) magnetic resonance angiography (MRA) in patients with peripheral arterial disease (PAD) using digital subtraction angiography (DSA) or contrast-enhanced magnetic resonance angiography (CE-MRA) as reference standard.

METHODS: This study was performed and reported according to the Preferred Reporting Items for Systematic reviews and Meta-analysis guidelines. A systematic literature search of MEDLINE, Embase and Scopus was done for studies reporting the diagnostic accuracy of QISS in PAD published up to 31 May 2021. The pooled sensitivity, specificity and diagnostic accuracy of QISS were calculated on a per-segment basis for the entire arterial tree.

RESULTS: Seventeen studies including 459 patients were found eligible for the meta-analysis. There was significant heterogeneity among studies as depicted by chi-square test (p = 0.02) and moderate heterogeneity by I2 statistic (I2: 69 [95% CI: 30-100]). The pooled sensitivity and specificity of QISS on a per-segment basis with DSA/CE-MRA as reference standard was 0.88 (95% CI: 0.85-0.91) and 0.94 (95% CI: 0.92-0.96) respectively. The area under hierarchical summary receiver-operating characteristic reflected a high accuracy of 0.96 (95% CI: 0.94-0.98). There was a low likelihood of publication bias as indicated by Deeks' funnel plot.

CONCLUSIONS: The present meta-analysis has consolidated the evidence that QISS has high accuracy for identifying as well as excluding arterial stenosis/occlusions in patients with symptoms of PAD. It can thus be considered the test of choice in patients with renal failure and in "at-risk patients" including pregnant women and patients with contrast allergy.

KEY POINTS: • The pooled sensitivity and specificity of QISS magnetic resonance angiography on a per-segment basis with DSA or contrast-enhanced MRA as reference standard are 88% and 94% respectively. • The diagnostic accuracy of QISS in patients with peripheral arterial disease as reflected by area under hierarchical summary receiver-operating characteristic is high (0.96 (95% CI: 0.94-0.98)). • There is moderate to significant heterogeneity among studies as depicted by I2 statistic and chi-square test.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Verma, Pandey, Singh, et al. A meta-analysis of the diagnostic performance of quiescent-interval-single-shot magnetic resonance angiography in peripheral arterial disease. Eur Radiol. 2021. PMID: 34766201. doi:10.1007/s00330-021-08349-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。