非闭塞性肠系膜缺血(NOMI)的CT预后征象:再灌注与否是关键
本研究回顾性分析84例确诊NOMI患者的增强CT,评估血管、肠系膜、肠壁及腹膜腔的定量与二分类参数与预后的关系。结果显示再灌注征象(血管增多增粗、肠壁增厚、血供丰富)多见于预后良好者,而无灌注征象(肠系膜苍白、肠壁薄如纸、乏血供、气腹)多见于预后不良者。多因素分析中仅下腔静脉直径和肠壁强化差值(Delta HU)独立预测预后,联合AUC为0.806。
要点
- 再灌注CT征象(血管增多、肠壁增厚、血供丰富)提示NOMI预后良好。
- 无灌注征象(肠系膜苍白、肠壁薄、乏血供、气腹)提示预后不良。
- 下腔静脉直径联合肠壁强化差值可预测NOMI预后,AUC为0.806。
核心结论
- NOMI患者的CT再灌注与无灌注二分类征象及定量参数可预测预后,下腔静脉直径与肠壁强化差值联合预测准确性最高(AUC 0.806)。
研究设计与样本
- 回顾性研究,纳入84例确诊NOMI患者(37例临床和实验室确诊,47例活检或手术证实),分析增强CT的血管、肠系膜、肠壁及腹膜腔定量与二分类参数。
关键影像表现/征象
- 预后良好者更常见血管数量及直径增加、肠壁增厚和血供丰富。
- 预后不良者更常见肠系膜苍白、肠壁薄如纸、乏血供和气腹。
诊断标准与关键数值
- 单因素分析显示肠系膜上动脉、腹腔干、下腔静脉、肠系膜上静脉直径及肠壁强化差值(Delta HU)与预后显著相关。
临床应用与阅片要点
- 阅片时应关注血管直径、肠壁厚度及强化程度,识别再灌注与无灌注征象以辅助预后判断。
- 下腔静脉直径和肠壁强化差值可作为定量预测指标,但需结合临床综合评估。
局限性
- 回顾性研究,样本量有限(84例),部分病例确诊方式不一致(临床/实验室 vs 活检/手术)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Non-occlusive mesenteric ischemia (NOMI) is a misdiagnosed and dangerous condition. To our knowledge, a comprehensive evaluation of CT parameters that can predict the outcome of patients suffering from NOMI is still missing.
MATERIALS AND METHODS: Contrast-enhanced CT examination of 84 patients with a confirmed diagnosis of NOMI (37 with clinical and laboratory confirmation and 47 biopsy or surgery proven) was retrospectively reviewed by assessing vessels, mesentery, bowel, and peritoneal cavity CT quantitative and dichotomous parameters, and data were analyzed with Fisher's test. Diameter of superior mesenteric artery (SMA), celiac trunk (CT), inferior vena cava (IVC), superior mesenteric vein (SMV), and differences in CT HU (Delta HU) of the bowel wall before and after intravenous contrast media (ICM) administration were correlated to the patients' outcome using ANOVA test. Receiver operating characteristic (ROC) curves were elaborated after a binary logistic regression was performed.
RESULTS: Increased number and diameter of vessels, bowel wall thickening, and hypervascularity were more frequent in patients with good prognosis. Conversely, pale mesentery, paper thin, hypovascularity, and aeroportia were more frequent in patients with bad prognosis. A significant correlation between diameters of SMA, CT, IVC, IMA, and SMV and outcome was found at univariate analysis. Also Delta HU resulted to be correlated with the outcome. At multivariate analysis only IVC and Delta HU were significant (p = 0.038 and 0.01) and the combined AUC resulted in 0.806 (CI 0.708-0.903).
CONCLUSION: Dichotomous signs of reperfusion and quantitative CT parameters can predict the outcome of patients with NOMI. In particular the combination of IVC diameter and Delta HU of bowel wall allows to predict the prognosis with the highest accuracy.
引用
- Bagnacci, Guerrini, Gentili, et al. Non-occlusive mesenteric ischemia (NOMI) and prognostic signs at CT: reperfusion or not reperfusion that is the question! Abdom Radiol (NY). 2021. PMID: 34755202. doi:10.1007/s00261-021-03317-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。