文献速递胸部CT

随访肺癌筛查CT中新发与既有结节的肺癌风险

Cancer Risk in Nodules Detected at Follow-Up Lung Cancer Screening CT.
PubMed 文献 · AJR Am J Roentgenol · 2021-11-10

该回顾性研究纳入185例有既往CT的肺癌筛查患者,比较Lung-RADS与NELSON分类对随访CT检出结节的评估效能。结果显示临床Lung-RADS的AUC达0.96,优于严格Lung-RADS(0.81)和NELSON算法(0.71-0.84),新发结节的最佳直径阈值(6mm)小于既有结节(8mm)。

要点

  • 临床实际应用的Lung-RADS在随访筛查中表现优异,AUC达0.96。
  • 新发结节的最佳直径阈值为6mm,小于既有结节的8mm。
  • 严格按Lung-RADS v1.1标准会将部分癌症降级为2类,需警惕。

关键影像表现/征象

  • 加权癌症风险:新发结节5%,稳定既有结节1%,增大的既有结节44%。
  • 临床Lung-RADS 2类结节中无癌症。
  • 严格Lung-RADS v1.1标准将34个结节(含7个癌症)降级为2类。

诊断标准与关键数值

  • 临床Lung-RADS诊断癌症的AUC为0.96,严格Lung-RADS为0.81,NELSON算法(两名读者)为0.71-0.84,结节直径测量为0.89。
  • 临床Lung-RADS全样本加权敏感度100%、特异度85%;新发结节敏感度100%、特异度41%;既有结节敏感度100%、特异度94%。
  • 既有结节最佳直径阈值为8mm,新发结节为6mm。

临床应用与阅片要点

  • 随访筛查中应区分新发与既有结节,新发结节采用更小尺寸阈值(6mm)判断风险。
  • 临床Lung-RADS分类在随访中效能高,但严格按v1.1标准可能将部分癌症降为2类,报告时需结合临床实际分类。
  • 体积评估(NELSON)在随访场景中效能低于临床Lung-RADS,阅片时不应单独依赖体积分类。

局限性

  • 回顾性单中心研究,样本经分层随机抽样富集可疑结节,可能影响结果外推。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Nodules may have different lung cancer risks when new on follow-up CT versus when present on previously performed CT (i.e., existing nodules). Diameter-based Lung-RADS and volume-based NELSON (Nederlands-Leuvens Longkanker Screenings ONderzoek trial) categories have shown variable performance in nodule risk assessment. OBJECTIVE. The purpose of this study was to assess Lung-RADS and NELSON classifications of nodules detected on follow-up lung cancer screening CT examinations. METHODS. This retrospective study included 185 patients (100 women and 85 men; median age, 66 years) who underwent a lung cancer screening CT examination for which a prior CT examination was available. Stratified random sampling was performed to enrich the sample with suspicious nodules, yielding 50, 45, 47, 30, and 13 nodules with Lung-RADS categories 2, 3, 4A, 4B, and 4X, respectively. Lung-RADS categories were recorded from clinical reports. The linear measurements of the nodules were extracted from clinical reports to generate Lung-RADS categories by use of strict criteria from Lung-RADS version 1.1. Two radiologists used a semiautomated tool to obtain nodule volumes, which were used to generate NELSON categories. Lung cancer risk was assessed. ROC analysis was performed. Percentages and AUCs were weighted on the basis of Lung-RADS category frequencies in the underlying screening cohort. RESULTS. Twenty-nine cancers were diagnosed. The weighted cancer risk was 5% for new nodules, 1% for stable existing nodules, and 44% for growing existing nodules. None of the clinical Lung-RADS category 2 nodules were cancer. With use of strict Lung-RADS version 1.1 criteria, 34 nodules, including seven cancers, were downgraded to category 2. The AUC for cancer was 0.96 for clinical Lung-RADS, 0.81 for strict Lung-RADS, 0.71-0.84 for the NELSON algorithm (two readers), and 0.89 for nodule diameter measurement. Clinical Lung-RADS achieved weighted sensitivity and specificity, respectively, of 100% and 85% for the entire sample, 100% and 41% for new nodules, and 100% and 94% for existing nodules. The optimal diameter threshold was 8 mm for existing nodules versus 6 mm for new nodules. CONCLUSION. Lung-RADS, as applied by radiologists in clinical practice, achieved excellent performance on follow-up screening examinations. Strict Lung-RADS resulted in the downgrading of some cancers to category 2. Volumetric assessments had weaker performance than clinical Lung-RADS. New nodules warrant smaller size thresholds than existing nodules. CLINICAL IMPACT. The findings of the present study provide insight into radiologists' management of nodules detected on follow-up screening examinations.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Hammer, Byrne. Cancer Risk in Nodules Detected at Follow-Up Lung Cancer Screening CT. AJR Am J Roentgenol. 2021. PMID: 34755524. doi:10.2214/AJR.21.26927

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。