文献速递技术与安全CT

基于图像质量要求的CT分类框架用于辐射剂量评估

An Image Quality-informed Framework for CT Characterization.
PubMed 文献 · Radiology · 2021-11-09

该回顾性研究利用加州大学旧金山分校国际CT剂量登记处2016-2019年成人CT检查的DICOM元数据,按身体部位和临床指征所需的图像质量将检查分为19类,并计算每类的剂量长度乘积中位数和75百分位(诊断参考水平)。

要点

  • CT剂量评估可按身体部位和图像质量要求分类,类别间剂量差异远大于类别内指征间差异。
  • 头、胸、腹、心脏的高剂量类别中位剂量显著高于低剂量类别,支持指征分类的有效性。
  • 该框架有助于标准化CT协议选择和辐射剂量比较。

局限性

  • 回顾性研究设计
  • 数据来自单一登记处

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Lack of standardization in CT protocol choice contributes to radiation dose variation. Purpose To create a framework to assess radiation doses within broad CT categories defined according to body region and clinical imaging indication and to cluster indications according to the dose required for sufficient image quality. Materials and Methods This was a retrospective study using Digital Imaging and Communications in Medicine metadata. CT examinations in adults from January 1, 2016 to December 31, 2019 from the University of California San Francisco International CT Dose Registry were grouped into 19 categories according to body region and required radiation dose levels. Five body regions had a single dose range (ie, extremities, neck, thoracolumbar spine, combined chest and abdomen, and combined thoracolumbar spine). Five additional regions were subdivided according to dose. Head, chest, cardiac, and abdomen each had low, routine, and high dose categories; combined head and neck had routine and high dose categories. For each category, the median and 75th percentile (ie, diagnostic reference level [DRL]) were determined for dose-length product, and the variation in dose within categories versus across categories was calculated and compared using an analysis of variance. Relative median and DRL (95% CI) doses comparing high dose versus low dose categories were calculated. Results Among 4.5 million examinations, the median and DRL doses varied approximately 10 times between categories compared with between indications within categories. For head, chest, abdomen, and cardiac (3 266 546 examinations [72%]), the relative median doses were higher in examinations assigned to the high dose categories than in examinations assigned to the low dose categories, suggesting the assignment of indications to the broad categories is valid (head, 3.4-fold higher [95% CI: 3.4, 3.5]; chest, 9.6 [95% CI: 9.3, 10.0]; abdomen, 2.4 [95% CI: 2.4, 2.5]; and cardiac, 18.1 [95% CI: 17.7, 18.6]). Results were similar for DRL doses (all P < .001). Conclusion Broad categories based on image quality requirements are a suitable framework for simplifying radiation dose assessment, according to expected variation between and within categories. © RSNA, 2021 See also the editorial by Mahesh in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Smith-Bindman, Yu, Wang, et al. An Image Quality-informed Framework for CT Characterization. Radiology. 2021. PMID: 34751618. doi:10.1148/radiol.2021210591

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。