外院颈椎CT报告在钝性创伤中的准确性与临床效用
总体不一致率为6.5%,其中2.8%的颈椎损伤在外院判读中未被发现。经两位资深神经放射学家裁定,二次判读将颈椎骨折检测的敏感度从95.7%提升至99.3%,特异度从91.7%提升至99.1%(P < .001)。
要点
- 外院与接收医院颈椎CT判读不一致率为6.5%,其中2.8%为漏诊颈椎损伤。
- 二次判读显著提高颈椎骨折检测敏感度(99.3% vs 95.7%)和特异度(99.1% vs 91.7%)。
- 对转诊钝性创伤患者,接收医院重新判读颈椎CT具有临床获益。
诊断标准与关键数值
- 次级判读检测颈椎骨折的敏感度为99.3%,初级判读为95.7%。
- 次级判读检测颈椎骨折的特异度为99.1%,初级判读为91.7%。
- 敏感度和特异度差异的P值均小于.001。
临床应用与阅片要点
- 对转诊的钝性创伤患者,接收医院应重新判读外院颈椎CT,以减少漏诊颈椎骨折。
- 外院报告无骨折但存在临床疑虑时,需警惕2.8%的漏诊率,考虑二次判读。
局限性
- 回顾性研究设计。
- 单中心研究,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Multidetector CT is the workhorse for detecting blunt cervical spine injury. There is no standard of care for re-interpretation of radiology images for patients with blunt trauma transferred to a higher level of care. The clinical impact of discrepancies of cervical spine CT reads remains unclear. We evaluated the discordance between primary (from referring hospitals) and secondary radiology interpretations (from a receiving level I tertiary trauma center) of cervical spine CT scans in patients with blunt trauma and assessed the clinical implications of missed cervical spine fractures.
MATERIALS AND METHODS: Medical records of patients with blunt trauma transferred to our institution between 2008 and 2015 were reviewed. Primary and secondary interpretations were compared and categorized as concordant and discordant. Two senior neuroradiologists adjudicated discordant reports. The benefit of re-interpretation was determined. For discordant cases, outcomes at discharge, injury severity pattern, treatment, and arrival in a cervical collar were assessed.
RESULTS: Six hundred fifty patients were included; 608 (94%) presented with concordant reports: 401 (61.7%) with fractures and 207 (31.8%) with no fractures. There were 42 (6.5%) discordant reports; 18 (2.8%) were cervical spine injuries undetected on the primary interpretation. Following adjudication, the secondary interpretation improved the sensitivity (99.3% versus 95.7%) and specificity (99.1% versus 91.7%) in detecting cervical spine fractures compared with the primary interpretation alone (P < .001).
CONCLUSIONS: There was an overall 6.5% discordance rate between primary and secondary interpretations of cervical spine CT scans. The secondary interpretation of the cervical spine CT increased the sensitivity and specificity of detecting cervical spine fractures in patients with blunt trauma transferred to higher-level care.
引用
- Rao, Engelbart, Yanik, et al. Accuracy and Clinical Utility of Reports from Outside Hospitals for CT of the Cervical Spine in Blunt Trauma. AJNR Am J Neuroradiol. 2021. PMID: 34737184. doi:10.3174/ajnr.A7337
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。