先进CT技术用于肝脏微波消融区监测与随访
本研究评估了高约束反投影(HYPR)和双能CT(DECT)在肝脏微波消融术中及术后监测中的效用。动物实验和初步人体研究表明,这些技术可提高图像质量、对比噪声比和消融区锐利度,但DECT辐射剂量较高。
要点
- 术中CT监测时,消融产生的气体可提供高对比噪声比,4分钟时最佳。
- DECT(51 keV和碘密度图)可改善术后消融区的对比噪声比和诊断信心。
- DECT辐射剂量较常规CT略高,需权衡获益与风险。
关键影像表现/征象
- 术中微波消融产生的气体导致所有术中CT数据集的高对比噪声比(CNR)。
- 术后DECT图像(碘密度图/51 keV)在所有时间点均显示比常规CT更高的CNR,无论全剂量还是半剂量对比剂。
- 人体研究中,51 keV和碘密度图的CNR和SNR均高于常规CT,消融区锐利度和诊断信心也更高。
诊断标准与关键数值
- 术中4分钟时CNR:低剂量常规CT 6.7,低剂量常规CT+HYPR 15.5,DECT 15.9,DECT+HYPR 21.5(p < 0.001)。
- 半剂量对比剂术后猪模型CNR:常规CT 1.5,DECT 3.2,DECT+HYPR 4.6(p < 0.001)。
- 人体研究CNR:51 keV 5.8,碘密度图 4.8,常规CT 4.0(p < 0.001);SNR:51 keV 3.7,碘密度图 5.9,常规CT 2.8。
- 消融区锐利度评分:常规CT 3.0 ± 0.7,DECT 3.5 ± 0.5;诊断信心评分:常规CT 2.3 ± 0.9,DECT 2.6 ± 0.8。
- DECT平均DLP 905.7 ± 606 mGy-cm,CTDIvol 37.5 ± 21.2 mGy,有效剂量13.6 ± 9.1 mSv。
临床应用与阅片要点
- 术中监测可利用消融产生的气体作为天然对比,4分钟时图像质量最佳。
- 术后随访推荐使用DECT(51 keV或碘密度图)以提高消融区显示清晰度和诊断信心。
- 需注意DECT辐射剂量较高,应合理选择扫描方案。
局限性
- 动物实验样本量小(4只猪),人体研究样本量有限(12例患者)。
- 研究为前瞻性但非随机,且未报告长期随访结果。
- DECT辐射剂量较高,可能限制其广泛应用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate utility of advanced CT techniques including HighlY constrained back-projection and dual-energy CT for intra- and post-procedure hepatic microwave ablation zone monitoring.
METHODS: 8 hepatic microwave ablations were performed in 4 adult swine (5 min/65 W). Low-dose routine CECT and dual-energy CT images were obtained every 1 min during ablation. Images were reconstructed ± HYPR. Image quality and dose metrics were collected. 21 MWA were performed in 4 adult swine. Immediate post-procedure CECT was performed in the arterial, portal venous, and delayed phases using both routine and DECT imaging with full-dose weight-based IV contrast dosing. An additional 16 MWA were subsequently performed in 2 adult swine. Immediate post-procedure CT was performed with half-dose IV contrast using routine and DECT. 12 patients (10 M/2F, mean age 62.4 yrs) with 14 hepatic tumors (4 HCC, 10 metastatic lesions) treated with MWA were prospectively imaged with DECT 1 month post-procedure. 120 kV equivalent images were compared to DECT [51 keV, iodine material density]. Image quality and dose metrics were collected.
RESULTS: Gas created during MWA led to high CNR in all intraprocedural CT datasets. Optimal CNRs were noted at 4 min with CNR 6.7, 15.5,15.9, and 21.5 on LD-CECT, LD-CECT + HYPR, DECT, and DECT + HYPR, respectively (p < 0.001). Image quality scores at 4 min were 1.8, 2.8, 2.4, and 3, respectively (p < 0.001). Mean radiation dose (CTDIvol) was eightfold higher for the DECT series. For swine, post-procedural DECT images (IMD/51 keV) showed improved CNR compared to routine CT at all time points with full and with reduced dose contrast (CNR 4.6, 3.2, and 1.5, respectively, at half-contrast dose, p < 0.001). For human subjects, the 51 keV and IMD images showed higher CNRs (5.8, 4.8 vs 4.0, p < 0.001) and SNRs (3.7, 5.9 vs 2.8). Ablation zone sharpness was improved with DECT (routine 3.0 ± 0.7, DECT 3.5 ± 0.5). Diagnostic confidence was higher with DECT (routine 2.3 ± 0.9, DECT 2.6 ± 0.8). Mean DLP for DECT was 905.7 ± 606 mGy-cm, CTDIvol 37.5 ± 21.2 mGy, and effective dose 13.6 ± 9.1 mSv, slightly higher than conventional CT series.
CONCLUSION: Advanced CT techniques can improve CT image quality in peri-procedural hepatic microwave ablation zone evaluation.
引用
- Lubner, Ziemlewicz, Wells, et al. Advanced CT techniques for hepatic microwave ablation zone monitoring and follow-up. Abdom Radiol (NY). 2021. PMID: 34731282. doi:10.1007/s00261-021-03333-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。