文献速递骨肌DRMR

髌骨不稳患者与无髌骨不稳患者髌骨高度测量在X线平片与磁共振成像上的观察者间与观察者内可靠性

Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging.
PubMed 文献 · Skeletal Radiol · 2021-10-31

该病例对照研究比较复发性髌骨不稳患者与对照组,由两名观察者在X线平片和MRI上测量六种经验证的髌骨高度指数,评估观察者间与观察者内可靠性。结果显示多数指数在两组间及两种影像模态间存在显著差异(p < 0.05),Insall-Salvati比率在X线和MRI上观察者间可靠性最高(ICC = 0.79至0.97;p < 0.001)(k = 0.50至1.00;p < 0.001)。作者认为X线与MRI测量的髌骨高度指数显著不同,可能提示每种影像模态需要不同的正常参考值。

要点

  • Insall-Salvati比率在X线和MRI上观察者间可靠性最高(ICC = 0.79至0.97;p < 0.001)。
  • 多数髌骨高度指数在髌骨不稳组与对照组间存在显著差异(p < 0.05)。
  • 多数髌骨高度指数在X线与MRI两种模态间存在显著差异(p < 0.05)。

核心结论

  • 髌骨高度指数在X线与MRI上测量结果显著不同,可能提示每种影像模态需要不同的正常参考值;Insall-Salvati比率整体表现最佳,在X线和MRI上均显示高度的观察者内与观察者间可靠性。

研究设计与样本

  • 病例对照研究,比较复发性髌骨不稳组(髌骨组)与对照组;髌骨组44例,对照组50例;两名观察者在两个不同时间点于X线平片和MRI上测量六种经验证的髌骨高度指数;采用组内相关系数(ICC)和kappa一致性检验评估观察者间与观察者内可靠性。

诊断标准与关键数值

  • Insall-Salvati比率在X线和MRI上观察者间可靠性最高(ICC = 0.79至0.97;p < 0.001)(k = 0.50至1.00;p < 0.001)。
  • 多数髌骨高度指数在髌骨组与对照组间存在显著差异(p < 0.05)。
  • 多数髌骨高度指数在X线与MRI两种模态间存在显著差异(p < 0.05)。

临床应用与阅片要点

  • 作者提出X线与MRI可能需要各自不同的髌骨高度正常参考值。
  • Insall-Salvati比率在X线和MRI上均显示高度的观察者内与观察者间可靠性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: Many patella height indices exist in the literature. There is no single universally accepted radiological assessment for measuring patella height. The aims of this study were to determine which of the commonly used indices can most reliably measure patella height and compare the findings on both plain X-ray and magnetic resonance imaging (MRI) of the knee.

METHODS: This case-controlled study compared patients with recurrent patella instability (patella group) to a control group. Two observers measured six validated patella height indices on X-ray and MRI of both groups at two separate time periods. Between-group and within-group statistical analysis was undertaken of the data. The inter- and intra-observer reliability was assessed using the intraclass correlation coefficient (ICC) and the kappa measure of agreement (k).

RESULTS: Forty-four patients comprised the patella group and 50 patients the control group. There was a significant difference of most indices between the two groups (p < 0.05). There was a significant difference of most indices between the two imaging modalities (p < 0.05). The Insall-Salvati ratio had the greatest inter-observer reliability for both X-ray and MRI (ICC = 0.79 to 0.97; p < 0.001) (k = 0.50 to 1.00; p < 0.001).

CONCLUSION: Patella height indices significantly differ when measured on X-ray as compared to MRI. This may infer that a different set of normative values are required for each radiological modality, which we have proposed in this study. Overall, the Insall-Salvati ratio performed best and shows a high degree of intra- and inter-observer reliability on both X-ray and MRI.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Picken, Summers, Al-Dadah, et al. Inter- and intra-observer reliability of patellar height measurements in patients with and without patellar instability on plain radiographs and magnetic resonance imaging. Skeletal Radiol. 2021. PMID: 34718849. doi:10.1007/s00256-021-03937-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。