文献速递胸部技术与安全CT

光子计数CT虚拟平扫与真实平扫肺定量对比

Quantitative Comparison of Virtual and True Noncontrast Lung Images in Photon-counting CT: Global and Regional Attenuation Assessment.
PubMed 文献 · Radiology · 2026-01-01

本回顾性研究纳入83例同日行平扫及增强胸部光子计数CT的患者,从增强扫描重建虚拟平扫(VNC)图像。比较VNC与真实平扫(TNC)的全肺及区域衰减参数,结果显示两者肺体积、平均衰减一致,吸气深度是衰减变异的主要来源。

要点

  • VNC与TNC肺体积、平均衰减无显著差异,可用于减少一次平扫辐射。
  • VNC图像肺气肿区域比例略被低估,正常衰减区略被高估。
  • 吸气深度对肺衰减测量影响大于重建方式,阅片时需注意呼吸配合。

核心结论

  • VNC与TNC在全肺及区域肺衰减测量上具有良好一致性,吸气深度是衰减变异的主要来源。

研究设计与样本

  • 回顾性研究,纳入2021年11月至2024年1月期间83例同日行平扫及增强胸部光子计数CT的患者。
  • 平均年龄60.0岁±15.0,其中47例为男性。
  • 从增强扫描数据重建VNC,与同次TNC进行配对比较。

关键影像表现/征象

  • VNC与TNC平均肺体积分别为4143 mL±1375和4111 mL±1384,差异无统计学意义。
  • VNC与TNC平均肺衰减分别为-799 HU±56和-798 HU±56,差异无统计学意义。
  • 配准后体素级分析显示肺实质内VNC与TNC衰减差仅为0.6 HU±15.1,解剖界面处差异更明显。

诊断标准与关键数值

  • 调整吸气深度后VNC与TNC平均差为-0.8 HU±19.5,95%一致限为-39.1至37.5 HU。
  • 肺气肿区域在VNC上轻度低估,中位差-0.4%(IQR -1.4%至0.1%)。
  • 正常衰减肺区在VNC上轻度高估,中位差+0.8%(IQR -1.3%至1.7%)。
  • 高密度类别分布差异无统计学意义。

临床应用与阅片要点

  • VNC图像可用于肺体积与平均衰减的定量评估,减少平扫序列的辐射剂量。
  • 评价肺气肿比例时需注意VNC可能轻微低估,判读正常肺区时需注意轻微高估趋势。
  • 肺衰减测量比较时,优先校正吸气深度,否则变异可能掩盖真实差异。

局限性

  • 单中心回顾性设计。
  • 体素级分析仅在一部分患者中完成。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Use of virtual noncontrast (VNC) images from photon-counting CT (PCCT) may reduce radiation dose and support quantitative lung analysis by obviating the need for separate true noncontrast (TNC) acquisitions. Their accuracy for lung densitometry, however, has not been systematically assessed. Purpose To evaluate agreement between VNC and TNC images for global and regional lung attenuation measurements in thoracic PCCT. Materials and Methods This retrospective study included patients who underwent same-day unenhanced and contrast-enhanced thoracic PCCT between November 2021 and January 2024. VNC datasets were reconstructed from contrast-enhanced scans. Lung volume, mass, and attenuation were compared using paired t tests, Wilcoxon signed-rank tests, and Bland-Altman analysis. Inspiratory depth effects were assessed with linear regression. Density class distributions were compared, and voxel-wise attenuation differences were evaluated in a subset of patients after nonlinear registration. Results This study included 83 patients (mean age, 60.0 years ± 15.0 [SD]; 47 men). Mean lung volume (4143 mL ± 1375 vs 4111 mL ± 1384; P = .41) and mean attenuation (-799 HU ± 56 vs -798 HU ± 56; P = .91) were similar between VNC and TNC images. After adjustment for inspiratory depth, VNC and TNC images demonstrated no systematic bias, and attenuation differences demonstrated substantially lower variability after adjustment than before adjustment (mean difference, -1.1 HU ± 5.9 vs -0.8 HU ± 19.5), with corresponding 95% limits of agreement of -12.6 to 10.5 HU and -39.1 to 37.5 HU, respectively. Density class analysis demonstrated that emphysematous areas were slightly underestimated (median, -0.4% [IQR, -1.4% to 0.1%]; P < .001) and normal-attenuation lung areas were modestly overestimated (median, +0.8% [IQR, -1.3% to 1.7%]; P < .001) on VNC images, without relevant changes in higher-density classes (both P ≥ .71). Voxel-wise differences were minimal within parenchyma (mean, 0.6 HU ± 15.1; P = .76) but more pronounced at anatomic interfaces. Conclusion In patients who underwent thoracic PCCT, VNC images demonstrated agreement with TNC scans for lung volume and attenuation, and inspiratory depth, rather than reconstruction method, was the dominant source of attenuation variability. © RSNA, 2026 Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Bodlien, Scharm, Hunkemöller, et al. Quantitative Comparison of Virtual and True Noncontrast Lung Images in Photon-counting CT: Global and Regional Attenuation Assessment. Radiology. 2026. PMID: 42808896. doi:10.1148/radiol.253972

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。