文献速递神经PET

动态18F-FDG PET在局灶性癫痫中的临床结果

Clinical outcomes of dynamic [18F]-FDG PET in focal epilepsy: a prospective early observational study.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-09-29

本前瞻性早期观察研究纳入31例局灶性药物难治性癫痫患者,在常规术前评估基础上加做动态FDG-PET(dPET),将全脑动力学图分为36个感兴趣区并转换为个体内z分数图,以低于全脑均值1.67个标准差为低动力学阈值。dPET结果未参与手术决策。

要点

  • dPET低动力学区最常见于近中颞叶结构,有助于定位致痫灶。
  • 在MRI正常或双重病理的术后无发作患者中,dPET仍可与致痫灶一致。
  • dPET目前仅作为术前定位辅助手段,不能单独用于手术决策。

核心结论

  • dPET通过测量葡萄糖代谢率而非静态浓度,可在手术证实的病例中高度一致地识别致痫灶对应区域,包括结构性影像无定位价值的病例。
  • 本研究为早期阶段,样本量不足以确立诊断准确性,但结果支持进一步研究dPET作为局灶性药物难治性癫痫术前定位的无创辅助手段。

研究设计与样本

  • 研究类型为前瞻性早期观察性研究,样本量为31例局灶性药物难治性癫痫成年患者。
  • 所有患者接受dPET及常规术前评估,全脑动力学图分割为36个感兴趣区并转换为个体内z分数图。
  • 低动力学区域定义为动力学值低于全脑均值至少1.67个标准差的区域。
  • 手术决策独立于dPET结果进行,主要结局为最低动力学z分数区域与致痫灶之间的观察一致性,以术后6个月癫痫发作结局评估。

关键影像表现/征象

  • 8例术后无致残性发作患者中,7例(88%)dPET低动力学区与手术致痫灶一致,包含MRI正常或双重病理病例。
  • 2例术后非无发作患者的dPET结果与手术靶区不一致。

诊断标准与关键数值

  • 低动力学阈值定义为感兴趣区动力学值低于全脑均值1.67个标准差。

临床应用与阅片要点

  • dPET低动力学区最常见于近中颞叶结构,阅片时应重点关注该区域是否出现低于1.67个标准差的动力学减低。
  • 当常规MRI无定位价值或存在双重病理时,dPET低动力学区仍可能指向致痫灶,可作为术前定位的无创辅助参考。

局限性

  • 本研究为早期阶段研究,样本量不足以确立诊断准确性。
  • 手术决策独立于dPET,仅用手术证实病例评估一致性,存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Standard static 18F-fluorodeoxyglucose PET (sPET) frequently registers normal metabolism in patients with focal drug-resistant epilepsy (DRE), limiting its utility for identifying the epileptogenic zone (EZ) for epilepsy surgery. Dynamic FDG-PET (dPET), which quantifies the rate of glucose uptake rather than its static concentration, may offer improved sensitivity. This early phase, prospective, observational study evaluated the concordance between dPET-defined hypokinetic regions and surgical outcomes in patients with focal DRE.

MATERIALS AND METHODS: Thirty-one adult patients with focal DRE underwent dPET along with standard pre-surgical evaluations. Whole-brain kinetic maps were segmented into 36 regions of interest and converted to intrasubject z-score maps; regions with kinetic values at least 1.67 standard deviations below the whole-brain mean were considered hypokinetic. Surgical decision-making proceeded independently of dPET findings. The primary outcome was observed agreement between the region of lowest kinetic z-score and the EZ, assessed by 6 month post-surgical seizure outcome.

RESULTS: Twenty-nine of 31 patients (94%) had at least one region exceeding the hypokinetic threshold, most commonly in mesial temporal structures. Ten patients underwent resective surgery; 8 achieved freedom from disabling seizures at 6 months. Among the 8 seizure-free, 7 (88%) had a dPET hypokinetic region concordant with the surgical EZ, including cases with normal MRI or dual pathology. dPET findings did not coincide with the surgical target in the 2 patients with non-seizure-free outcomes.

CONCLUSIONS: These findings suggest that dPET, by capturing metabolic rate rather than concentration, can identify regions that correspond to the EZ with a high degree of concordance in surgically confirmed cases, including many with nonlocalizing structural imaging. While this early phase study is not powered to establish diagnostic accuracy, the results support further investigation of dPET as a noninvasive adjunct for presurgical localization in focal drug-resistant epilepsy.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Quigg, Chernyavskiy, Terrell, et al. Clinical outcomes of dynamic [18F]-FDG PET in focal epilepsy: a prospective early observational study. AJNR Am J Neuroradiol. 2026. PMID: 42810826. doi:10.3174/ajnr.A9657

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。