文献速递神经CT

超高分辨率光子计数CT血管成像三维容积重建评估颅内动脉瘤

3D Volume Rendering of Ultrahigh-Resolution Photon-Counting Detector CT Angiography for Preoperative Assessment of Intracranial Aneurysms: Initial Experience.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-09-28

本回顾性研究纳入21例患者共32个颅内动脉瘤,由两名神经外科医师评估2D UHR与3DVR数据集。3DVR图像质量及临床实用性被评为优秀,2D-CTA与3DVR在瘤顶和瘤颈径线上一致性良好。研究支持UHR PCD-CTA结合3DVR用于颅内动脉瘤术前形态评估的技术可行性与可重复性。

要点

  • 3DVR图像质量与临床实用性均被评为优秀,可用于动脉瘤术前可视化。
  • 瘤顶及瘤颈径线在2D-CTA与3DVR间一致性良好(ICC=0.83及0.82)。
  • 3DVR测量存在轻微系统性低估,阅片者间变异大于影像方法间变异。

核心结论

  • UHR PCD-CTA三维容积重建可高质量显示颅内动脉瘤,与2D UHR CTA测量一致性良好。
  • 该技术方法具有技术可行性和可重复性,但阅片者相关因素可能影响测量差异。

研究设计与样本

  • 回顾性研究,21例患者共32个颅内动脉瘤。
  • 两名神经外科医师评估2D UHR和3DVR数据集,采用问卷主观评分。
  • 采用组内相关系数(ICC)和Bland-Altman分析评估方法间及阅片者间一致性。

关键影像表现/征象

  • 3DVR图像质量被评为优秀。
  • 3DVR临床实用性被评为优秀。
  • Bland-Altman分析显示3DVR存在轻微系统性测量低估。
  • 测量变异在阅片者间数值上大于影像方法间。

诊断标准与关键数值

  • 瘤顶径线2D-CTA与3DVR一致性ICC=0.83,95% CI 0.66-0.92,p<0.01。
  • 瘤颈径线2D-CTA与3DVR一致性ICC=0.82,95% CI 0.59-0.92,p<0.01。
  • 3DVR重建瘤顶径线阅片者间信度ICC=0.74,95% CI 0.52-0.87,p<0.01。
  • 3DVR重建瘤颈径线阅片者间信度ICC=0.55,95% CI 0.23-0.76,p<0.01。

临床应用与阅片要点

  • UHR PCD-CTA结合3DVR可用于颅内动脉瘤术前形态评估的可视化展示。
  • 3DVR与2D测量一致性良好,可用于瘤顶和瘤颈径线评估。
  • 阅片者间瘤颈径线信度仅为中等,报告时应关注测量标准化。

局限性

  • 回顾性研究设计。
  • 样本量较小(21例患者32个动脉瘤)。
  • 阅片者间信度中等,尤其瘤颈径线ICC仅为0.55。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Three-dimensional volume rendering (3DVR) enables the detailed visualization of complex vascular anatomy. However, the utility of combining ultrahigh-resolution (UHR) photon-counting detector CT angiography (PCD-CTA) with 3DVR post-processing for preoperative intracranial aneurysm assessment has not yet been evaluated. This study explored whether combining UHR PCD-CTA with 3DVR post-processing provides reliable morphologic assessment and reproducible size measurements in the preoperative evaluation of intracranial aneurysms. In this retrospective study of 32 aneurysms in 21 patients, two neurosurgeons evaluated 2D UHR and 3DVR datasets. Image quality, aneurysm characterization, and clinical usefulness were subjectively rated via questionnaire, while inter-modality and inter-reader agreement for dome and neck dimensions were assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Image quality and clinical usefulness of 3DVR images were rated as excellent. Agreement between 2D-CTA and 3DVR was good for both dome (ICC = 0.83, 95% CI 0.66-0.92, p<0.01) and neck size (ICC = 0.82, 95% CI 0.59-0.92, p<0.01). Inter-reader reliability on 3DVR reconstructions was moderate for dome (ICC = 0.74, 95% CI 0.52-0.87, p<0.01) and neck size (ICC = 0.55, 95% CI 0.23-0.76, p<0.01). Bland-Altman analysis demonstrated a small systematic underestimation on 3DVR, with measurement variability numerically greater between readers than between imaging approaches. In conclusion, UHR PCD-CTA-based 3DVR provides high-quality visualization of intracranial aneurysms with good agreement compared with 2D UHR CTA measurements. These findings support the technical feasibility and reproducibility of this approach, though reader-related factors may influence measurement differences.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Tóth, Silbergleit, Al Kasab, et al. 3D Volume Rendering of Ultrahigh-Resolution Photon-Counting Detector CT Angiography for Preoperative Assessment of Intracranial Aneurysms: Initial Experience. AJNR Am J Neuroradiol. 2026. PMID: 42805793. doi:10.3174/ajnr.A9650

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。