ADPKD平扫CT全肾体积快速自动分割方法

A rapid automated segmentation method for total kidney volume measurement on unenhanced computed tomography in autosomal dominant polycystic kidney disease.
PubMed 文献 · Abdom Radiol (NY) · 2026-09-26

本研究基于nnU-Net开发并验证了一种在常染色体显性多囊肾病(ADPKD)患者平扫CT图像上全自动测量全肾体积(TKV)的方法。开发队列含236例患者,独立验证队列含70例ADPKD患者,参考标准由两位放射科医师半自动分割后逐层手动校正。自动分割与参考标准在空间和体积一致性上表现优异,平均DSC为0.96±0.01,ICC为0.999(95%CI 0.998-0.999)。

要点

  • 平扫CT自动测量TKV约5秒/例,远快于专家辅助分割约30分钟/例
  • 自动分割体积偏倚极小(-0.14%),精度高(±2.09%),可直接用于随访评估
  • 纵向评估肾脏增长一致性良好,ICC=0.99,偏倚-0.64%,精度±4.81%

核心结论

  • 该自动分割方法可在ADPKD患者平扫CT上实现快速、准确、可重复的TKV定量,具备替代手动体积分析的临床可行性。

研究设计与样本

  • 基于nnU-Net框架的全自动肾脏分割模型,开发集为236例患者平扫CT,其中111例为ADPKD
  • 开发集分为训练队列和内部测试队列,另设70例ADPKD独立验证队列,其中20例含纵向扫描
  • 参考标准由两位有经验的放射科医师独立进行半自动肾脏分割后逐层手动校正

关键影像表现/征象

  • 自动分割达到平均DSC 0.96±0.01的全肾体积空间重合度
  • 体积一致性接近完美:ICC=0.999(95%CI 0.998-0.999),偏倚-0.14%,精度±2.09%
  • 纵向肾脏增长评估一致性可靠:ICC=0.99,偏倚-0.64%,精度±4.81%
  • 自动方法约5秒/例,专家辅助参考分割约30分钟/例,时间差异明显

诊断标准与关键数值

  • 全肾体积自动分割平均Dice相似系数(DSC)为0.96±0.01
  • 自动与参考标准体积一致性ICC=0.999(95%CI 0.998-0.999),偏倚-0.14%,精度±2.09%
  • 纵向增长的体积变化评估ICC=0.99,偏倚-0.64%,精度±4.81%
  • 自动分割处理时间约5秒/例,专家辅助参考分割约30分钟/例

临床应用与阅片要点

  • 平扫CT上可对ADPKD患者TKV进行全自动定量,适合用于日常随访中肾脏体积变化评估
  • 阅片报告可引用自动分割TKV,减少手动勾画的时间成本和操作者间差异
  • 纵向扫描的肾脏增长评估一致性良好,可用于监测疾病进展,无需增强扫描

局限性

  • 本研究为单中心研究,开发集与验证集均来自有限的患者群体
  • 部分局限性未在摘要中详细报告,需查阅原文确认具体限制
  • 参考标准依赖放射科医师手动校正,仍可能存在主观差异

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop and validate a fully automated deep learning-based method for total kidney volume (TKV) measurement from unenhanced computed tomography (CT) images in patients with autosomal dominant polycystic kidney disease (ADPKD).

METHODS: A fully automated kidney segmentation model based on the nnU-Net framework was developed using unenhanced CT images from 236 patients, including 111 patients with ADPKD. The development dataset was divided into a training cohort and an internal testing cohort. An independent cohort of 70 patients with ADPKD was used for validation, including longitudinal scans from 20 patients. The reference standard consisted of semi-automated kidney segmentation followed by slice-by-slice manual correction performed independently by two experienced radiologists. Automated and reference segmentations were compared using the Dice similarity coefficient (DSC), intraclass correlation coefficient (ICC), linear regression and Bland-Altman analysis.

RESULTS: Automated segmentation exhibited excellent spatial agreement with the reference standard, with a mean DSC of 0.96 ± 0.01 for TKV. Volumetric agreement was near perfect (ICC = 0.999; 95% confidence interval, 0.998-0.999), with minimal bias (-0.14%) and high precision (±2.09%). Longitudinal analysis demonstrated robust agreement for kidney growth assessment (ICC = 0.99; bias, - 0.64%; precision, ± 4.81%). The automated method required approximately 5 s per case, compared with 30 min for expert-assisted reference segmentation.

CONCLUSION: This automated segmentation method enables fast, accurate, and reproducible TKV quantification from unenhanced CT images in patients with ADPKD, offering a clinically feasible alternative to manual volumetric analysis.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。