要点

  • 斑块强化分级是卒中复发的独立危险因素(OR=11.023,P=0.001),阅片时应重点评估斑块强化程度。
  • HR-VWI影像组学联合传统影像指标的联合模型预测效能最佳,训练集AUC为0.947,验证集AUC为0.925。
  • 复发组低密度脂蛋白和总胆固醇水平更高、斑块负荷更低、斑块强化程度更高(P=0.004)。

核心结论

  • HR-VWI影像组学特征与传统影像指标联合模型对sICAS患者卒中复发具有较好的预测效能,训练集AUC为0.947,验证集AUC为0.925。
  • 斑块强化分级是卒中复发的独立危险因素,OR=11.023,P=0.001。

研究设计与样本

  • 所有样本按7:3比例随机分为训练集(n=63)和验证集(n=27),训练集中采用SMOTE技术处理类别不平衡问题。
  • 在T1WI和增强T1WI图像上测量斑块影像特征,勾画斑块感兴趣区并提取影像组学特征。

关键影像表现/征象

  • 复发组斑块负荷更低,斑块强化程度更高,差异有统计学意义(P=0.004)。
  • 斑块强化分级为独立危险因素(OR=11.023,P=0.001),提示斑块强化程度高者复发风险增加。

诊断标准与关键数值

  • 最终筛选出14个影像组学特征构建rad-score评分系统,影像组学特征空间共n=1920个。
  • 联合预测模型训练集AUC为0.947,验证集AUC为0.925,显著优于单一临床模型和独立影像组学模型。
  • 随访期间共26例患者(28.9%)发生卒中复发。

临床应用与阅片要点

  • 日常阅片中应重视HR-VWI增强序列上斑块强化程度的评估,强化明显者复发风险增高。
  • 基于HR-VWI的影像组学联合模型可通过列线图直观展示,为临床个体化预测提供参考。

局限性

  • 样本量有限(n=90,仅26例复发事件),影像组学特征空间维度高(n=1920),过度拟合风险高。
  • 单中心回顾性研究,结果需在更大独立队列中进行外部验证后方可临床转化。
  • 未进行先验功效计算,样本量基于研究期间完整HR-VWI及随访数据的可获得性确定。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Based on high-resolution vessel wall imaging (HR-VWI) and radiomics, this study constructed a predictive model for stroke recurrence in patients with symptomatic intracranial atherosclerotic stenosis (sICAS), and evaluated the performance of the model.

MATERIALS AND METHODS: This study retrospectively included 90 patients with sICAS who were treated in a tertiary hospital in China from January 2020 to December 2024. No a priori power calculation was performed; the sample size was based on the availability of complete HR-VWI and follow-up data during the study period. The imaging features of plaques were measured in T1WI and enhanced T1WI images of all patients, and the regions of interest of plaques were delineated and radiomics features were extracted. All the samples were randomly divided into training set (n = 63) and validation set (n = 27) at a ratio of 7 : 3. To address class imbalance, we employed the Synthetic Minority Over-sampling Technique (SMOTE) within the training set during model development. After feature screening, radiomic score (rad-score) was constructed. Based on the conventional imaging features, radiomics features and clinical related information of vascular plaques, the clinical prediction model, radiomics prediction model and the combined model of the two were established in turn. Receiver operating characteristic (ROC), area under the curve (AUC), calibration curve and decision curve analysis (DCA) were used to comprehensively evaluate the predictive efficacy of various models. At the same time, a nomogram was constructed to visualize the model, providing an intuitive reference for clinical practice.

RESULTS: During the follow-up period, a total of 26 patients (28.9%) had stroke recurrence. Patients in the recurrence group had higher levels of low-density lipoprotein and total cholesterol, lower plaque load, and higher degree of plaque enhancement, and the differences were statistically significant (P = 0.004), and plaque enhancement grade was an independent risk factor (OR = 11.023, P = 0.001). Finally, a total of 14 radiomics features were selected to construct the rad-score scoring system. In the training set and validation set, the AUC corresponding to the combined prediction model reached 0.947 and 0.925, respectively, and its prediction efficiency was significantly better than that of a single clinical model and an independent radiomics model. The nomogram showed good calibration and high clinical net benefit.

CONCLUSION: The combined model of HR-VWI radiomics features and traditional imaging indicators has excellent performance in the prediction of stroke recurrence in sICAS patients. However, due to the limited sample size (n = 90, with only 26 recurrent events) and the high-dimensional radiomic feature space (n = 1920), Our findings are at a high risk of overfitting. Despite the use of rigorous regularization techniques (LASSO) and internal cross-validation, the results should be interpreted as preliminary and hypothesis-generating. These findings are from a single-center study and urgently require external validation in larger independent cohorts before clinical translation.