文献速递泌尿生殖腹部MR

MRI质量对前列腺靶向活检准确性的影响:前瞻性PI-QUAL分析

Impact of MRI quality on the accuracy of targeted prostate biopsy: A prospective PI-QUAL analysis.
PubMed 文献 · Eur J Radiol · 2026-09-16

本研究前瞻性纳入124例患者,采用PI-QUAL v2评分评估多参数MRI的T2W、DWI及DCE序列图像质量,比较MRI靶向活检与系统活检对临床有意义前列腺癌的检出差异。结果显示15例(12.1%)靶向活检漏诊更高Gleason分级组,T2W图像质量欠佳是靶向活检失败的主要预测因素。

要点

  • 图像质量以PI-QUAL v2评分评估,重点关注T2W、DWI及DCE三个序列。
  • T2W序列质量欠佳与靶向活检失败显著相关(单因素p=0.003),是主要影响因素。
  • PI-QUAL评分低时,MRI靶向活检相对系统活检优势下降,建议复查MRI。

核心结论

  • MRI图像质量欠佳,尤其是T2W序列质量不佳,是MRI靶向活检失败的主要驱动因素。
  • PI-QUAL评分低时,临床医生应意识到MRI相对系统活检对癌症检出的提升有限。
  • 理想情况下,低PI-QUAL评分的MRI应重复扫描,以优化临床有意义前列腺癌的检出。

研究设计与样本

  • 前瞻性研究,纳入124例患者。
  • 采用PI-QUAL v2评分对T2W、DWI和DCE序列进行图像质量评估。
  • 以系统活检检出Gleason分级组高于靶向活检定义为靶向活检「漏诊」。
  • 统计学方法包括Mann-Whitney U检验和多因素logistic回归。

关键影像表现/征象

  • 15例患者(12.1%)出现靶向活检漏诊,即系统活检检出更高Gleason分级组。
  • T2W序列质量欠佳与靶向活检失败显著相关(单因素p=0.003)。
  • DCE序列质量欠佳与靶向活检失败相关(p=0.015)。
  • 多因素模型中,T2W质量仍为靶向活检不准确的临床强预测因子。

诊断标准与关键数值

  • 图像质量分级采用PI-QUAL v2评分,分别评估T2W、DWI和DCE序列。
  • T2W质量为靶向活检失败的预测因子,优势比12.1,95%置信区间0.9–164.7,p=0.06。
  • 靶向活检漏诊定义为系统活检检出Gleason分级组高于靶向活检。

临床应用与阅片要点

  • 阅片时应常规使用PI-QUAL v2评分评估mpMRI图像质量,重点关注T2W序列。
  • PI-QUAL评分低时,报告应提示MRI靶向活检相对系统活检的增量价值有限。
  • 对低质量MRI,优先建议复查,而非直接依赖靶向活检定位。
  • DCE序列质量欠佳也与靶向活检失败有关,报告中应一并记录。

局限性

  • 多因素模型中T2W质量预测因子的95%置信区间较宽(0.9–164.7),估计精度有限。
  • T2W质量在多因素模型中的p值为0.06,未达到传统显著性水平。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND OBJECTIVES: Multiparametric MRI (mpMRI) has improved the detection of clinically significant prostate cancer (csPCa). However, the diagnostic utility of mpMRI is heavily dependent on image quality, which is often inconsistent across clinical settings. We investigated the association between mpMRI quality, assessed via the Prostate Imaging Quality (PI-QUAL) score, and the accuracy of MRI-targeted biopsies (TBx) compared to systematic biopsies (SBx).

METHODS: In this prospective study of 124 patients, image quality was evaluated for T2-weighted (T2W), diffusion-weighted, and dynamic contrast-enhanced (DCE) sequences using PI-QUAL v2. A biopsy "miss" was defined as a case where SBx detected a higher Gleason grade group than TBx. Statistical analyses, including Mann-Whitney U tests and multivariate logistic regression, were employed to identify predictors of TBx failure.

RESULTS: A total of 15 patients (12.1%) had a TBx "miss." Univariate analysis revealed that suboptimal T2W (p = 0.003) and DCE (p = 0.015) quality were significantly associated with biopsy failure. In a multivariate model, T2W quality remained a clinically potent predictor of inaccuracy (Odds ratio: 12.1, 95% confidence interval: 0.9-164.7, p = 0.06).

CONCLUSION: Suboptimal MRI quality, particularly the T2W sequence, is a primary driver of TBx failure. When faced with low PI-QUAL scores, clinicians should remain aware that MRI is less likely to improve detection of cancer compared to SBx. Ideally, low PI-QUAL score MRIs should be repeated to optimize the detection of csPCa.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wunsch Iii, Esengur, Makwana, et al. Impact of MRI quality on the accuracy of targeted prostate biopsy: A prospective PI-QUAL analysis. Eur J Radiol. 2026. PMID: 42777336. doi:10.1016/j.ejrad.2026.113254

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。