文献速递骨肌技术与安全CT

光子计数CT脊柱融合术后金属伪影:120 keV联合iMAR评估

Photon-counting detector CT with virtual monoenergetic imaging and iterative metal artifact reduction for spinal fusion implants: optimal keV and combined benefits.
PubMed 文献 · Eur J Radiol · 2026-09-13

前瞻性纳入66例脊柱内固定术后患者,行光子计数探测器CT扫描,比较常规多色谱图、100-140 keV虚拟单能谱及iMAR联合重建的减伪影效果。结果显示120 keV整体图像质量最优,联合iMAR虽显著降低金属伪影但引入新伪影。

要点

  • 脊柱融合术后PCD-CT推荐优先重建120 keV虚拟单能谱图像。
  • 120 keV联合iMAR可进一步降金属伪影,但需警惕新伪影。
  • 常规多色谱图在椎体及邻近结构显示上劣于所有VMI重建。

核心结论

  • PCD-CT对脊柱内固定物金属伪影提供有效处理,120 keV是优选重建能级。
  • 120 keV虚拟单能谱联合iMAR显著降低金属伪影,但会引入新伪影,需谨慎应用。

研究设计与样本

  • 前瞻性研究,连续纳入66例脊柱内固定术后患者,共70次扫描。
  • 采用临床光子计数探测器CT系统,重建常规多色谱图、100-140 keV虚拟单能谱图及iMAR图像。
  • 客观图像质量通过五个预设解剖区域的图像噪声和伪影指数进行量化。
  • 主观评估由两名放射科医师独立采用5分Likert量表评价伪影程度及邻近解剖结构可见性。

关键影像表现/征象

  • 所有虚拟单能谱重建均较常规多色谱图显示更低噪声、更低伪影指数。
  • 虚拟单能谱重建对椎体及邻近解剖结构的可见性和诊断信心均优于常规多色谱图。
  • 联合120 keV虚拟单能谱与iMAR显著降低金属伪影,但同时引入新伪影。

诊断标准与关键数值

  • 120 keV虚拟单能谱在主观和客观评估中均显示最佳整体图像质量。
  • 所有虚拟单能谱重建的噪声、伪影指数、可见性及诊断信心均优于常规多色谱图,P小于0.0001。

临床应用与阅片要点

  • 脊柱内固定术后PCD-CT阅片可优先采用120 keV虚拟单能谱重建。
  • 使用120 keV联合iMAR时需注意评估新引入伪影对邻近结构的影响。
  • 常规多色谱图对椎体和邻近结构显示欠佳,不建议作为首看序列。

局限性

  • 联合iMAR引入新伪影,影响其单独评价价值,需临床谨慎使用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the effectiveness of virtual monoenergetic imaging (VMI) and iterative metal artifact reduction (iMAR), alone and in combination, for reducing metal artifacts in postoperative CT scans of patients with spinal fusion, using a clinical photon-counting detector CT (PCD-CT) system.

MATERIALS AND METHODS: Consecutive patients after spinal instrumentation were prospectively included in this study and received PCD-CT imaging of spine. Image reconstructions comprised conventional polychromatic images (PI), virtual monoenergetic images (VMI) at 100-140 keV, and iterative metal artifact reduction (iMAR) for determining the optimal keV. Further a combined optimal keV VMI with iMAR was reconstructed. Objective image quality was quantified by image noise and artifact index (AIx) measured across five predefined anatomical regions. Subjective assessment was performed independently by two radiologists using a 5-point Likert scale to grade artifact severity and the visibility of adjacent anatomical structures.

RESULTS: 66 patients (32 males, 34 females; 60.5 ± 14.2 years) with a total of 70 scans were enrolled. All VMI reconstruction provided lower noise, lower AIx and better visibility and diagnostic confidence for both vertebra and adjacent anatomical structures than polychromatic images (P < 0.0001). Subjective and objective assessments in first step showed that 120 keV provided superior overall imaging quality. The further combination of 120-keV VMI with iMAR resulted in significantly lower metal artifacts but introduced new artifacts.

CONCLUSIONS: For spinal implants, PCD-CT offers effective approaches for metal artifact and 120 keV is preferred. The combination of iMAR and 120 keV introduce new artifacts and requires careful consideration.