光子计数CT评估冠状动脉支架:诊断效能研究
回顾性单中心研究纳入141例冠状动脉支架术后患者,比较光子计数CT(PCCT)与能量积分探测器CT(EID-CT)对支架内再狭窄≥50%的检出能力。PCCT图像质量更高、不可诊断支架比例更低,对ISR≥50%的准确度高。
要点
- PCCT的支架不可诊断比例显著低于EID-CT(1.1%比46.8%)。
- PCCT检出ISR≥50%的灵敏度高,阴性预测值达100%。
- 真阳性ISR的ISR/ISL比值趋势低于假阳性,提示可辅助鉴别。
核心结论
- PCCT对冠状动脉支架评估的图像质量优于EID-CT,对ISR≥50%的检出准确度高。
- PCCT有潜力克服传统EID-CT在冠状动脉支架评估中的技术局限。
研究设计与样本
- 回顾性单中心研究,纳入141例冠状动脉支架术后转诊冠状动脉CTA的连续患者。
- 70例患者176枚支架接受PCCT检查,71例患者126枚支架接受EID-CT检查作为对照组。
- 以有创冠状动脉造影(ICA)为参考标准评估ISR≥50%。
关键影像表现/征象
- PCCT组支架主观图像质量评分高于EID-CT组(p<0.001)。
- PCCT组不可诊断支架比例低于EID-CT组(1.1%比46.8%,p<0.001),图像质量优秀支架比例更高(70.5%比23%,p<0.001)。
- 真阳性ISR≥50%的ISR/ISL比值平均值低于假阳性(0.35比0.87)。
诊断标准与关键数值
- 支架内管腔图像质量采用3级评分:2=「诊断质量优秀」,1=「诊断质量有限」,0=「不可诊断」。
- PCCT患者水平检出ISR≥50%的准确度90.48%(71.09,97.35),灵敏度100%(64.57,100),特异度85.71%(60.06,95.99)。
- PCCT患者水平检出ISR≥50%的阳性预测值77.78%(45.26,93.68),阴性预测值100%(75.75,100)。
- PCCT支架水平检出ISR≥50%的准确度88.52%(78.16,94.33),灵敏度100%(70.08,100),特异度86.54%(74.73,93.32)。
- PCCT支架水平检出ISR≥50%的阳性预测值56.25%(33.18,76.90),阴性预测值100%(92.13,100)。
临床应用与阅片要点
- PCCT可作为冠状动脉支架术后无创随访的可靠选择,尤其当常规EID-CT支架评估受限时。
- PCCT阴性结果对排除ISR≥50%可靠性较高,可减少不必要的ICA。
- ISR/ISL比值可作为形态学定量参数辅助区分真假阳性狭窄。
局限性
- 回顾性单中心研究设计。
- 样本为连续转诊患者,存在选择偏倚可能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the diagnostic performance of photon-counting computed tomography (PCCT) coronary angiography for the detection of in-stent restenosis (ISR) ≥ 50%, and image quality.
MATERIALS AND METHODS: 141 consecutive patients with coronary stents referred to coronary computed tomography angiography (CTA) were enrolled in this retrospective single-center study, using either PCCT or energy-integrating detector (EID)-CT. Image quality of the in-stent lumen (ISL) was graded using a 3-point scale as 2 = "excellent diagnostic", 1 = "limited diagnostic", or 0 = nondiagnostic. Coronary stents were assessed for ISR ≥ 50% compared to invasive coronary angiography (ICA), and quantitative image analysis was performed.
RESULTS: 176 stents in 70 patients (age 73.64 ± 12.6, 27.1% women) who underwent PCCT were included and compared to a control group of 71 patients (126 stents) who underwent EID-CT. Subjective image quality scores were higher in stents assessed by PCCT compared with EID-CT (p < 0.001). The rate of nondiagnostic stents was lower (1.1% vs 46.8%, p < 0.001) with PCCT, while the proportion of stents excellent image quality was higher (70.5% vs 23%, p < 0.001). The diagnostic accuracy of PCCT (per-patient) for the detection of ISR ≥ 50% was 90.48% (71.09, 97.35), sensitivity 100% (64.57, 100), specificity 85.71% (60.06, 95.99), PPV 77.78% (45.26, 93.68), NPV 100% (75.75, 100), and per-stent: accuracy 88.52% (78.16, 94.33), sensitivity 100% (70.08, 100), specificity 86.54% (74.73, 93.32), PPV 56.25% (33.18, 76.90) and NPV 100% (92.13, 100). True positive ISR ≥ 50% showed a trend toward lower ISR/ISL ratios than false positives (mean, 0.35 vs 0.87).
CONCLUSIONS: Image quality of PCCT for coronary stent evaluation is improved compared to EID-CT, and the accuracy for detection of ISR ≥ 50% is high.
KEY POINTS: Question Does photon-counting CT improve the diagnostic accuracy for detection of in-stent restenosis (ISR) ≥ 50%, and image quality compared with energy-integrating detector (EID) CT? Findings Photon-counting CT provides higher image quality and a low rate of nondiagnostic stents (0.3%). For detecting ≥ 50% ISR, the diagnostic accuracy is high and the PPV is moderate. Clinical relevance Photon-counting computed tomography (PCCT) has the potential to overcome technical limitations of conventional energy-integrating CT in coronary stent assessment and could improve the reliability of non-invasive follow-up after percutaneous coronary intervention.
引用
- Lacaita, Bilgeri, Spitaler, et al. In vivo coronary stent evaluation using photon-counting computed tomography: diagnostic performance. Eur Radiol. 2026. PMID: 42763334. doi:10.1007/s00330-026-12860-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。