文献速递骨肌儿科影像MR

儿童孤立性骨肿瘤MRI:Bone-RADS与OT-RADS验证研究

Can bone tumor radiology reporting systems be used in children?: a validation study for Bone-RADS and OT-RADS in MRI in the evaluation of solitary bone tumors.
PubMed 文献 · Eur Radiol · 2026-09-17

结果显示两种报告系统均可靠且准确性较高,Bone-RADS因有算法指导,观察者间一致性更高。

要点

  • Bone-RADS与OT-RADS均可用于儿童孤立性骨肿瘤MRI评估。
  • Bone-RADS观察者间一致性高于OT-RADS,可能因有算法指导。
  • OT-RADS缺乏完整术语词典和算法,需结合具体疾病知识判读。

核心结论

  • Bone-RADS与OT-RADS在儿童孤立性骨肿瘤MRI评估中均可靠且准确性较高。
  • Bone-RADS观察者间一致性高于OT-RADS,归因于其算法提供的指导。

研究设计与样本

  • 患者平均年龄11.95岁(标准差3.65,范围4–17岁),其中66例为男性。
  • 5名不同专业水平的放射科医生评估MRI,采用Cohen’s kappa和Fleiss’ kappa评估观察者间一致性,二分类模型评估诊断性能。

诊断标准与关键数值

  • Bone-RADS所有评估者总体一致性Fleiss kappa为0.470(95% CI 0.410–0.530),呈中度一致。
  • OT-RADS所有评估者总体一致性Fleiss kappa为0.432(95% CI 0.389–0.475),呈中度一致。
  • Bone-RADS准确性为中等至良好,OT-RADS准确性为中等至优秀。

临床应用与阅片要点

  • 儿童孤立性骨肿瘤MRI报告可参考Bone-RADS,利用其算法提升观察者间一致性。
  • 使用OT-RADS时需熟悉各疾病影像特征,因其缺乏完整术语词典和算法支持。

局限性

  • 原文未报告本研究的具体局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Bone tumor radiology reporting systems have been developed, including Bone-RADS and OT-RADS, aimed at standardizing imaging studies' reports and guiding the management of bone lesions. This study aims to evaluate and compare the use of Bone Tumor Radiology Reporting Systems, Bone-RADS and OT-RADS, in MRI of children with solitary bone lesions.

MATERIALS AND METHODS: Patients younger than 18 years old who had an MRI for the evaluation of a solitary bone lesion between January 2015 and October 2025 were included in the study. Five radiologists with different expertise levels evaluated the MRI examinations. Bone-RADS and OT-RADS were assessed using both their original categorical systems and binary classification models. We assessed inter-rater reliability using Cohen's kappa and Fleiss' kappa. For both scoring systems, a binary classification was used to assess diagnostic performance.

RESULTS: Eighty patients (mean age - standard deviation/minimum-maximum: 11.95 - 3.65/4-17 years old; 66 male) were included in the study. For both Bone-RADS and OT-RADS, the overall agreement between all raters, as assessed using Fleiss Kappa, showed moderate agreement (k = 0.470, 95% CI: 0.410-0.530) and (k = 0.432, 95% CI: 0.389-0.475), respectively. The accuracy of Bone-RADS ranged from moderate to good, and OT-RADS from moderate to excellent.

CONCLUSION: Both Bone-RADS and OT-RADS were reliable, and demonstrated high accuracy in evaluating solitary bone tumors in children. Bone-RADS has a higher level of interrater agreement, which we attributed to the guidance provided by its algorithm. OT-RADS requires knowledge of each disease due to the lack of a comprehensive lexicon and an algorithm.

KEY POINTS: Question Can bone tumor radiology reporting systems, Bone-RADS and OT-RADS in MRI, be used in the evaluation of solitary bone tumors? Findings Both Bone-RADS and OT-RADS demonstrated moderate interrater agreement in the evaluation of solitary bone tumors in children. Bone-RADS revealed moderate to good accuracy, while OT-RADS revealed moderate to excellent accuracy. Clinical relevance Bone-RADS and OT-RADS were reliable and demonstrated high accuracy in evaluating solitary bone tumors in children. These bone reporting systems can be used for solitary bone tumors in children on MRI.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Sağlam, Kaya, Erdemli Gürsel, et al. Can bone tumor radiology reporting systems be used in children?: a validation study for Bone-RADS and OT-RADS in MRI in the evaluation of solitary bone tumors. Eur Radiol. 2026. PMID: 42752923. doi:10.1007/s00330-026-12899-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。