比较双侧M1段形态发现,动脉瘤同侧M1相对长度低于对侧。探索性分析显示同侧M1几何参数与动脉瘤壁强化及血流动力学特征存在初步相关,但FDR校正后未达显著。

要点

  • 大脑中动脉分叉部动脉瘤同侧M1段相对长度低于对侧(P=0.035),提示载瘤动脉几何形态可能存在侧别差异。
  • M1相对长度与动脉瘤壁强化比值及最大流入速度呈名义正相关,但FDR校正后不显著,解读需谨慎。
  • M1最大半径与时间平均壁面剪切应力呈名义负相关,尚待更大样本验证。

核心结论

  • 单侧大脑中动脉分叉部动脉瘤患者中,动脉瘤同侧与对侧M1段几何形态存在差异,同侧相对长度更低。
  • 同侧载瘤动脉几何参数与动脉瘤壁强化及血流动力学特征存在探索性相关关系,FDR校正后未达显著,需更大独立队列验证。

研究设计与样本

  • 所有患者均接受四维血流(4D-flow)和高分辨率(HR)磁共振成像。
  • M1段形态在标准化双侧节段上量化,相对长度(RLength)为迂曲度参数,计算方法为中心线端点间直线距离除以中心线长度,最大半径(Radiusmax)为尺寸参数。

关键影像表现/征象

  • 动脉瘤同侧M1段相对长度(RLength)低于对侧(0.95 [0.85-0.99] vs. 0.97 [0.94-0.99];P=0.035)。
  • 同侧M1相对长度与动脉瘤-垂体柄平均对比度比值(CRstalk-avg)呈名义正相关(r=0.539,原始P=0.008,FDR校正q=0.403)。
  • 同侧M1相对长度与最大流入速度(Vmax)呈名义正相关(r=0.444,原始P=0.034,FDR校正q=0.560)。
  • 同侧M1最大半径(Radiusmax)与时间平均壁面剪切应力(TAWSS)呈名义负相关(r=-0.511,原始P=0.013,FDR校正q=0.403)。

诊断标准与关键数值

  • 相对长度(RLength)定义为M1中心线端点间直线距离除以中心线长度,作为迂曲度参数。
  • 最大半径(Radiusmax)作为M1尺寸参数。
  • 动脉瘤壁强化采用动脉瘤-垂体柄平均对比度比值(CRstalk-avg)评估。
  • 血流动力学参数包括最大流入速度(Vmax)和时间平均壁面剪切应力(TAWSS)。
  • 探索性相关分析采用Spearman相关,并使用Benjamini-Hochberg假发现率法校正多重比较。

临床应用与阅片要点

  • 在日常阅片中,评估大脑中动脉分叉部动脉瘤时,可同时关注同侧M1段相对长度和对侧M1段形态差异。
  • M1相对长度偏低可能与动脉瘤同侧载瘤动脉形态重塑有关,但该发现对个体病例的诊断价值尚不明确。
  • 动脉瘤壁强化和血流动力学参数与M1形态的相关性目前仅为探索性,不应作为临床报告中的确定性结论引用。

局限性

  • 研究本身为单中心回顾性研究,且未在摘要中报告多中心或前瞻性设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Parent artery geometry may be associated with the imaging phenotype of intracranial aneurysm. This study aimed to compare ipsilateral and contralateral M1 morphology in patients with unilateral middle cerebral artery (MCA) aneurysms and to explore the associations between parent artery geometry, aneurysm wall enhancement (AWE), and hemodynamic features.

METHODS: For this retrospective study, patients with unilateral MCA bifurcation aneurysms from our maintained database were included. All patients underwent four-dimensional (4D)-flow and high-resolution (HR) magnetic resonance imaging (MRI). Parent artery morphology was quantified on standardized bilateral M1 segments, including relative length (RLength) as a tortuosity parameter, calculated as the straight-line distance between centerline endpoints divided by centerline length, and maximum radius (Radiusmax) as a dimensional parameter. Inter-side differences were assessed using paired statistical tests, and exploratory Spearman correlation analyses were performed between ipsilateral parent artery parameters and aneurysm imaging characteristics. The Benjamini-Hochberg false discovery rate method was used to adjust for multiple comparisons in the exploratory correlation analyses.

RESULTS: Twenty-three patients (aged 57 [53.50-64.00]; 26.1% male) were included. The ipsilateral M1 segment showed lower RLength than the contralateral side (0.95 [0.85-0.99] vs. 0.97 [0.94-0.99]; P = 0.035). In exploratory association analyses, higher RLength showed nominal positive correlations with average aneurysm-to-pituitary stalk contrast ratio (CRstalk-avg; r = 0.539, raw P = 0.008, FDR-adjusted q = 0.403) and maximal inflow velocity (Vmax; r = 0.444, raw P = 0.034, FDR-adjusted q = 0.560), whereas Radiusmax showed a nominal negative correlation with time-averaged wall shear stress (TAWSS; r = - 0.511, raw P = 0.013, FDR-adjusted q = 0.403).

CONCLUSION: In MCA bifurcation aneurysms, M1 geometry differed between the aneurysm ipsilateral and contralateral sides. Ipsilateral parent artery geometry showed preliminary exploratory relationships with aneurysm wall enhancement and hemodynamic features, which warrant further validation in larger independent cohorts.

来源:Neuroradiology,查看原文。版权归原作者所有。