急诊X线片髋部骨折AI诊断效能评估
回顾性诊断准确性研究纳入539例急诊≥60岁髋部/骨盆X线检查患者,以三名肌骨放射科医师和两名高年创伤骨科医师共识为参考标准,评估Milvue SmartUrgences AI软件的诊断表现。487例获得YES或NO明确分类的患者中,AI检测髋部骨折的敏感度为97.4%,特异度为86.5%,NPV为98.1%。结论认为该软件在急诊髋部骨折X线评估中有较高敏感度和阴性预测值,可辅助但不能替代临床与影像学评估。
要点
- AI分类为NO时,阴性预测值达98.1%,漏诊风险低但仍需结合临床判断。
- AI输出DOUBT的病例被单独评估,不纳入主要分析,阅片时需重点关注。
- AI输出YES的阳性预测值为82.3%,存在假阳性,应避免仅凭AI诊断骨折。
核心结论
- Milvue SmartUrgences在急诊连续队列中检测髋部骨折表现出高敏感度(97.4%)和高阴性预测值(98.1%)。
- AI输出可提供急性X线评估时的决策支持,但应作为临床和放射学评估的补充而非替代。
研究设计与样本
- 回顾性诊断准确性研究,纳入2023年6月至2024年9月两家急诊科连续≥60岁行髋部及骨盆X线检查的患者。
- 共纳入539例患者,487例获得AI明确分类(YES或NO)纳入主要分析,平均年龄83.4岁(SD 8.4),66%为女性。
- 参考标准为三名肌骨放射科医师与两名高年创伤骨科医师组成的共识小组,对AI输出设盲。
- 待评价测试为Milvue SmartUrgences软件,将X线片分类为「YES」「NO」或「DOUBT」。
诊断标准与关键数值
- 参考标准共确认191例髋部骨折。
- 主要分析中,AI检测髋部骨折的敏感度为97.4%(95%CI 94.0-98.9)。
- AI检测髋部骨折的特异度为86.5%(95%CI 82.1-89.9)。
- 阳性预测值为82.3%(95%CI 76.8-86.7),阴性预测值为98.1%(95%CI 95.6-99.2)。
- 准确度为90.8%(95%CI 87.9-93.0),F1-score为89.2%。
临床应用与阅片要点
- AI输出NO时阴性预测值极高,可用于快速分流低风险病例,但仍需结合临床体征和局部压痛综合判断。
- 遇到AI输出DOUBT的病例应视为不确定结果,建议进一步CT或MRI检查或短期随访复查。
局限性
- 回顾性诊断准确性研究设计,存在选择偏倚和信息偏倚的可能。
- AI输出DOUBT的病例被排除于主要分析之外,可能高估软件在真实临床全流程中的整体表现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the diagnostic performance of Milvue SmartUrgences AI software for detecting hip fractures on radiographs obtained in the emergency department (ED).
METHODS: This retrospective diagnostic accuracy study included consecutive patients aged ≥ 60 years undergoing hip and pelvis radiography at two EDs between June 2023 and September 2024. The index test was Milvue SmartUrgences, which classified radiographs as "YES," "NO," or "DOUBT." The reference standard was established by a consensus panel of three musculoskeletal radiologists and two senior orthopaedic trauma surgeons, blinded to AI output. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and F1-score were calculated. The primary analysis included patients with definitive "YES" or "NO" classifications; "DOUBT" classifications were evaluated separately.
RESULTS: Among 539 included patients, 487 received definitive AI classifications and were included in the primary analysis. The mean age was 83.4 years (SD 8.4), and 66% were female. The reference standard identified 191 hip fractures. Sensitivity was 97.4% (95% CI 94.0-98.9), and specificity was 86.5% (95% CI 82.1-89.9). PPV was 82.3% (95% CI 76.8-86.7), NPV 98.1% (95% CI 95.6-99.2), and accuracy 90.8% (95% CI 87.9-93.0). The F1-score was 89.2%.
CONCLUSIONS: Milvue SmartUrgences demonstrated high sensitivity and negative predictive value for hip fracture detection in a consecutive emergency department cohort. The software may provide useful decision support during acute radiographic assessment, but AI output should complement rather than replace clinical and radiological assessment.
引用
- Christensen, Elsoe, Mahdi, et al. Evaluating artificial intelligence in the diagnosis of hip fractures: an analysis of sensitivity, specificity, positive and negative predictive values, and accuracy. Skeletal Radiol. 2026. PMID: 42736479. doi:10.1007/s00256-026-05370-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。