不同CT方案自动耳蜗形态测量:头CT与颈动脉、颈椎、鼻窦CT比较

Automatic cochlear morphometry: intraindividual comparison of head CT vs carotid CT angiography, cervical spine, and paranasal sinus CT.
PubMed 文献 · Eur Radiol · 2026-09-15

回顾性纳入459例同时接受头CT及颈椎CT、颈动脉CTA或鼻窦CT的患者,行基于Corti器的自动耳蜗管长度测量。结果显示颈椎CT和鼻窦CT与头CT的CDL无个体内差异,颈动脉CTA差异虽显著但很小;低剂量方案可获得与头CT相当的CDL结果。

要点

  • 颈椎、颈动脉和鼻窦CT覆盖颞骨时,可机会性用于人工耳蜗CDL测量。
  • 各类非头CT方案辐射剂量均明显低于常规头CT,利于低剂量术前规划。
  • 阅片时即使CNR较低,自动CDL测量仍可保持较好一致性。

核心结论

  • 尽管CNR较低,基于颈椎、颈动脉和鼻窦CT的CDL测量结果与头CT相当,提示耳蜗形态测量具备大幅降低辐射剂量的潜力。

研究设计与样本

  • 回顾性研究,纳入459例患者(70.7±17.8岁,240例女性),均接受头CT(120 kVp)及颈椎CT(Sn 150 kVp,293例)、颈动脉CTA(100 kVp,133例)或鼻窦CT(Sn 100 kVp,33例)之一。
  • 自动CDL测量聚焦于Corti器,同时比较辐射剂量和对比噪声比。

关键影像表现/征象

  • 头CT的CTDIvol中位数53.2 mGy(四分位距49.6-56.8),高于颈椎CT16.3 mGy(15.6-16.9)、颈动脉CTA8.4 mGy(8.2-8.7)和鼻窦CT固定5.0 mGy。
  • 头CT的CNR中位数24.3(21.4-27.1),高于颈动脉CTA17.9(15.3-20.6)、颈椎CT12.3(10.9-13.6)和鼻窦CT6.6(5.7-7.4)。

诊断标准与关键数值

  • 头CT测得CDL中位数35.5 mm(34.4-36.5),颈椎CT测得35.5 mm(34.3-36.5),两方案无个体内差异(p=0.371)。
  • 鼻窦CT测得CDL中位数35.0 mm(34.3-36.1),与头CT无显著差异(p=0.112)。
  • 颈动脉CTA样本CDL中位数35.4 mm(34.4-36.4),与头CT存在小而显著的差异(p<0.001)。

临床应用与阅片要点

  • 日常阅片中,覆盖颞骨的颈椎、颈动脉和鼻窦CT可用于机会性自动CDL测量,辅助人工耳蜗电极阵列选择。
  • 不同扫描方案间CNR下降未明显影响CDL一致性,仍可将测量结果用于术前规划。

局限性

  • 本研究为回顾性设计,各替代方案组的样本量存在较大差异,其中鼻窦CT组仅33例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: In cochlear implantation, precise estimation of cochlear duct length (CDL) is essential for individualized electrode array selection. This study provides an intraindividual comparison of CDL measurements based on head CT vs cervical spine, carotid artery, and paranasal sinus imaging.

MATERIALS AND METHODS: For this retrospective investigation, automatic CDL measurements focused on the organ of Corti were performed in 459 patients (70.7 ± 17.8 years, 240 women), who underwent both head CT (120 kVp) and either cervical spine CT (Sn 150 kVp, 293 patients), carotid CT angiography (100 kVp, 133 patients), or paranasal sinus CT (Sn 100 kVp, 33 patients). Additionally, radiation dose and contrast-to-noise ratios were compared.

RESULTS: Head CT (median 53.2 [interquartile range 49.6-56.8] mGy) was associated with a higher CTDIvol than cervical spine (16.3 [15.6-16.9] mGy), carotid artery (8.4 [8.2-8.7] mGy), and paranasal sinus CT (fixed 5.0 mGy; p < 0.001). CNR was higher in head CT (24.3 [21.4-27.1]) compared with carotid artery (17.9 [15.3-20.6]), cervical spine (12.3 [10.9-13.6]), and paranasal sinus CT (6.6 [5.7-7.4]; p < 0.001). No intraindividual CDL difference was ascertained for head CT (35.5 [34.4-36.5] mm) vs cervical spine (35.5 [34.3-36.5] mm; p = 0.371) and paranasal sinus CT (35.0 [34.3-36.1] mm; p = 0.112), whereas a small, but statistically significant difference, was found in the carotid artery sample (35.4 [34.4-36.4] mm; p < 0.001).

CONCLUSION: Despite lower CNR, CDL measurements based on cervical spine, carotid artery, and paranasal sinus CT yield comparable results to head CT imaging, suggesting potential for considerable dose reduction in cochlear morphometry.

KEY POINTS: Question Do technically diverse low-dose protocols covering the temporal bone provide robust automatic CDL measurements in a large real-world patient sample? Findings In 459 patients, automatic cochlear morphometry from carotid angiography, cervical spine, and paranasal sinus CT was intraindividually comparable to head CT, despite lower CNR. Clinical relevance Validation of automatic CDL measurements from various routine CT protocols covering the temporal bone enables opportunistic cochlear implant planning with substantially reduced radiation exposure.

来源:Eur Radiol,查看原文。版权归原作者所有。